Version Parameter

ID Lock supports Door Lock Command Class Version 2 with the following parameters
"Firmware 1", "version and sub version" describes the version of ID Lock 150. Ie.
0x01 0x47 equals IDL-150 fw v1.4.7.
COMMAND_CLASS_VERSION_V2

10. User Codes (PINs and RFIDs)

10.1. User code ID status

In order to set or reset user codes of ID Lock 150, it is used
COMMAND_CLASS_USER_CODE_V1.
The User ID Status is defined as below for ID Lock 150
User ID Status
ID Lock
ID Lock Z-Wave Module Technical manual for FW 1.6
Name
Z-Wave Protocol Library Type
Z-Wave Protocol Version
Z-Wave Protocol Sub version
Firmware 0 Version
Firmware 0 Sub Version
Hardware Version
Number of Firmware targets
Firmware 1 Version
Firmware 1 Sub version
Parameter
idlock.no
Value
0x03
0x04
0x05
0x01
0x06
0x01
0x01
0x01
0x47
Value
0x00
Available (Not set)
When user code is deleted
0x01
Occupied
When user code is registered
0xFE
Status not available
When user code is all deleted