Filling with Maintenance Oil
① Open the Cover.
② Remove the Oil Fill Cap by turning it counter clockwise.
③ Remove the cap for Maintenance Oil and install the Oil Filling Nozzle.
④ Fill with Maintenance Oil slowly (Fig. 7).
⑤ When filling is complete, securely attach the Oil Fill Cap by turning it clockwise.
Do not fill Maintenance Oil in a room where there is a risk of explosion or fire.
•
Do not overfill Maintenance Oil in order to avoid accidental oil leaks. Pour slowly.
•
Maintenance of iCare
Cleaning the iCare
① Turn OFF (O side) the Power Switch.
② Remove the AC power cord from Unit.
③ Wipe the surface using a cloth moistened with water, warm water or soapy water
(neutral detergent), then again wipe using another cloth moistened with disinfectant
alcohol.
• Never use solvent such as benzine or thinner for cleaning.
• Do not leave an alcohol-immersed cloth in contact with the Unit for a long period.
Bleaching, deformation or failure of the Unit may occur.
• The door can easily be detached when necessary and be cleaned with tap water
NOTICE
(See Operation Manual "9-2 Detaching and reattaching the Door").
•
See Operation manual
9-3〜9-8
about the replacing of Mist Filter, Oil Absorber Sheet, O-ring, or changing Fuses.
"
"
•
Remove oil in the oil tank following Operation Manual
Draining the Air Filter
① When water accumulates in the Air Filter case,
press the Drain Button at the bottom of the case
to drain the Air Filter (Fig. 8).
② In addition to the Air Filter, drain the air supply
attached to this device (Air Compressor) at least
once a week.
9-6 Oil removal from the oil tank
, before relocating or requesting product service.
"
"
Drain the Air Compressor and Air Filter at least once a week as required. Moisture from
the tank could mix with the Maintenance Oil.
Fig.7
Fig.8
Drain Button
2014.03.20
OM-E0693E