Download Print this page
Manitowoc IF300 Manual

Manitowoc IF300 Manual

Clean and sanitize ice machine

Advertisement

Quick Links

Clean and sanitize ice machine
Why
To break the bacteria cycle
Time required
10 minutes to prepare
Time of day
At close
Hazard icons
Tools and supplies
Measuring Cup
Bucket, clean towels
Kay Delimer
Kay 5 Sanitizer
Procedure
1
Remove front panel.
Use a Phillips screwdriver to
loosen the two screws secur-
ing the door. Do not remove
screws completely; they are
secured to prevent loss.
2
Turn ice machine off.
After ice has fallen from the
evaporator, turn the machine
OFF.
Bucket, soiled towels
Ice scoop
©McDonald's Corporation · Planned Maintenance Manual · Revised February 2019
Monthly
90 minutes to complete
For 24-hour restaurants: during low-volume periods at
night
McD KL Delimer
McD DR Sanitizer
3
Empty ice bin.
Use an ice scoop to remove
all ice from the storage bin or
dispenser. Discard the ice.
If you are cleaning the ice
machine in the production
area, store the ice in the
freezer for use if needed.
BE 13 M1
Multi Surface
Screwdriver, Phillips
Glass Cleaner
Page 1 of 4

Advertisement

loading

Summary of Contents for Manitowoc IF300

  • Page 1 BE 13 M1 Clean and sanitize ice machine Monthly To break the bacteria cycle Time required 10 minutes to prepare 90 minutes to complete Time of day At close For 24-hour restaurants: during low-volume periods at night Hazard icons Tools and supplies Measuring Cup Bucket, clean towels Bucket, soiled towels...
  • Page 2 “Please add chemicals and confirm” is For models: displayed, then pour the pre- IF300, IT420, IT520, IT620 mixed solution into the water Kay Delimer - Mix 2 packets trough and press “Chemicals with 1 liter of warm water added”.
  • Page 3 Clean and sanitize ice machine (continued) Remove the water distribution DeLime plastic parts. tube. Mix the correct amount of delimer with 4 gallons Loosen the two outer screws (15 liters) of warm water in a (do not remove screws three-compartment sink. completely;...
  • Page 4 Prepare Sanitizer. Prepare the correct amount of sanitizer. Reinstall front panels and tighten screws. IF300, IT420, IT520, IT620 Kay 5 - Mix 1 packet with 1 liter of water. McD DR - Measure 25 ml IT1200, IF1400C, IT1500, IF1800C, IT1900, IF2100C Clean and sanitize bin.

This manual is also suitable for:

It420It520It620It1200If1400It1500 ... Show all