ELISIR 1. Introduction ............................5 1.1 Introduction and purpose of the Manual ..................5 1.1.1 Use of this Manual ........................5 1.2 Warranty conditions ........................5 1.3 Graphical conventions ........................5 1.4 Personnel qualifications ......................... 6 1.5 General warnings ........................... 6 1.5.1 To be arranged by the Customer ....................
Page 4
ELISIR 5. Instructions for use ..........................28 5.1 Correct use of the cabinet ......................28 5.2 Uses to be avoided ........................29 5.3 Working limits ..........................29 5.4 Cabinet control functions ......................29 5.4.1 Manual defrosting ........................29 6. Maintenance instructions ........................30 6.1 General warnings .........................
1. Introduction 1.1 Introduction and purpose of the Manual Thank you for choosing Criocabin S.p.a., hereinafter referred to as the Manufacturer. We are glad to have you as our Customer and hope you will be fully satisfied with this product.
ELISIR within the illustration. Illustration references and component references may be used at the same time (i.e. A - Fig. 1 or 1 - Fig. 1). The following graphical symbols are used in this Manual to draw users’ attention to information concerning proper and safe use of the product: NOTE! This symbol is used to highlight a piece of information or advice, or a rule whi-...
ELISIR Note! It is strictly forbidden to use them to carry out modifications on the product. Possible modifications are to be required directly to the Dealer, specifying all the product technical features and the reasons for such modifications; if approved, modifications must be carried out only by the Manufacturer’s personnel or by authorised personnel.
ELISIR 2. Information on safety 2.1 General regulations - Training • It is recommended that any person who interacts with the product reads this Manual completely before starting to operate. • Negligence or failure to comply with these safety regulations while using and maintaining the product may cause accidents for which the Dealer and the Manufacturer are not responsible.
Page 9
ELISIR Warning! If a refrigerant fluid comes into contact with eyes: do not rub the eyes; remove contact lens; rinse thoroughly for at least 20 minutes. If a lubricant comes into contact with skin: wash the skin with a great quantity of water for at least 20 minutes; leave the skin uncovered.
The product described in this manual is a display cabinet, hereinafter called "cabinet", multiplexable, in standard sizes, whose intended use is to display food sold: 3.1.1 Structural components. ELISIR 200 / 220 • Multiplexable. • Anti-fogging front ventilation. • Thermostatic refrigeration valve.
ELISIR 3.2 Technical characteristics In this manual all dimensions in the technical drawings are given in millimeters (mm). 3.2.1 Dimensions Fig. 1 Dimensions Elisir 200 220 340...
ELISIR 3.2.4 Admissible loads As for the cabinet admissible loads, refer to the following table: COMPONENTS LOAD Top canopies, alluminium max kg 20/m Top canopies, glass max kg 8/m Intermediate shelves max kg 8/m Display surfaces max kg 95/m 3.2.5 Refrigeration system: As for the refrigerant fluid characteristics, refer to the enclosed "Refrigerant fluid safety data sheet".
ELISIR Note! A room temperature rising and/or a lack of air to the condensing unit not only increases energy consumption but also reduces the cabinet technical performances and may lead to the deterioration of displayed products. The cabinet operating room temperature is 25 °C ± 1 °C. The environment humidity shall be 60% ± 3.6 Description of residual risks Warning! DANGER OF CUTTING...
ELISIR 3.7 Specific protections Normally, the refrigeration system components and the control panel are not accessible. They are sheltered by means of panels placed on the cabinet rear side. Prohibition! Except when special maintenance is performed, it is forbidden to remove the panels or use the cabinets when the panels have been removed or are open.
ELISIR 4.1.2 Handling and positioning Unless otherwise specified, the Customer is responsible for the above mentioned operations. To handle the cabinet use a forklift truck of suitable capacity. Refer to the gripping-lifting areas shown in the picture below. Fig. 4 Handling ELISIR Note! It is recommended to move the cabinet only by means of a pallet.
ELISIR 4.2 Unpacking and disposal of packaging materials Unless otherwise specified, the Customer is responsible for the operations mentioned below. Remove the packaging only after having positioned the unit. Packaging must be disposed of in compliance with the laws in force.
ELISIR 4.3 Assembly Unless otherwise specified, the Customer is responsible for the operations mentioned below. ELISIR UNIT CONNECTING KIT CANALIZZAZIONE TRA BANCO E BANCO - MULTIPLEXATION BETWEEN CABINET AND CABINET - CANALISATION VITRINE ET VITRINE - ZUSAMMENBAUSATZ ZWISCHEN THEKE UND THEKE RIF.
ELISIR 4.4 Disassembly and subsequent reassembly The Customer is responsible for the cabinet disassembly in order to move it and for its subsequent reassembly. For technical service, the Customer can apply to the Reseller. 4.5 Fixing The cabinet described in this manual is provided with screw feet and therefore does not need to be fixed to the floor.
ELISIR 4.7 Commissioning 4.7.1 Setting Start-up settings are performed in the factory during the testing procedure by the Manufacturer. As for set-up operation parameters, refer to the List of parameters in . To modify the above mentioned parameters, refer to the enclosed "Carel control unit instructions for use".
ELISIR Note! Front glasses must be lifted to their maximum opening point and kept open only as long as it takes to store or remove food, or for cleaning purposes. Pistons act as a lifting back- up and prevent the glass from accidental falling. If cabinets are provided with hatches, these must be opened only as long as it takes to store or remove food in order to avoid an anomalous rising of the cabinet working tem- perature.
ELISIR 6. Maintenance instructions 6.1 General warnings Maintenance operations described in this manual concern planned routine maintenance. The Customer is responsible for the routine maintenance of the equipment. Special maintenance shall be carried out only by qualified personnel according to what stated in the "Maintenance Manual", which is not an integral part of this manual.
ELISIR 6.3 Periodical maintenance 6.3.1 Check of the glass lifting system Qualified Check at least once a year that the glass lifting system works perfectly. 6.4 Special maintenance The maintenance of the refrigeration system components pertains to special maintenance operations. Refer to "Maintenance Manual".
ELISIR Prohibition! The refrigerant fluid is not easily biodegradable. It must not be discharged in ground waters, rivers, sewages or on the ground. 8. Attachments 8.1 Reference to manuals of other suppliers Instructions of control unit: as attached. Wiring diagram: attahed. 8.2 Declaration of conformity: as attached...