MeTer OVerVIeW We developed the revolutionary Pool eXact EZ photometer to easily ® maintain pool water quality. It uses state of the art technology to produce lab-quality results poolside. The Pool eXact EZ photometer ® is waterproof (IP-67) and has a built-in sample cell to enhance usability.
FIll, DIP, reAD STAnDArD STrIP MeThOD This method can be used with the following tests: Total Alkalinity Free Chlorine (DPD-1) Calcium Hardness Total Chlorine (DPD-4) Strip Micro (e.g. Free Chlorine / DPD-1) Remove one eXact ® from the bottle or foil packet and set in a dry, convenient place. Turn meter on by pressing ZERO/ON.
Page 5
FIll, DIP, reAD Rinse the sample cell 3 times with the water sample you are testing and Fill the built-in sample cell. Press ZERO/ON. The cursor will move across the display followed by 0 PPM or PH. Dip the eXact Strip Micro into the sample cell and ®...
FIll, DIP, reAD COMBIneD/TOTAl ChlOrIne TeST This procedure is a continuation from Standard Strip Method on previous page after running Free Chlorine (DPD-1). DO NOT DISCARD SAMPLE AFTER FREE CHLORINE TEST. Remove one (1) eXact Strip Micro CL (DPD-3), Part No. 486638 ®...
Page 7
FIll, DIP, reAD The cursor will move across the display while the meter measures the sample. reAD the Combined Chlorine value displayed. If you require a value for Total Chlorine, press READ again and record result displayed. After testing is complete, rinse the sample cell immediately.
FIll, DIP, reAD CYAnUrIC ACID TeST Turn meter on by pressing ZERO/ON. The display will indicate current menu, followed by the last test result. Press and re-press MENU until the display shows the parameter CY5. Rinse the sample cell 3 times with the water sample you will be testing and fi ll the sample cell.
Page 9
FIll, DIP, reAD Shake the bottle of eXact Reagent CY II, Part No. 481652-II ® to mix the suspension in the bottle. Add fi ve (5) drops of the eXact Reagent CY II to the sample cell. Keep reagent bottle ®...
ABOUT AccurAcy & cAlibrAtion All tests have been calibrated using certified reference standards and standard analytical spectrophotometric methods. The algorithms in the software reflect the best correlation of the Pool eXact EZ system ® against the AWWA, US EPA , DIN, and ISO reference test methods for chlorine.
TIPS • The Pool eXact EZ photometer has a 5 minute automatic shutdown timer. ® • Each test menu can store 20 results. To retrieve the stored results, go to the desired test using the MENU key. When the desired test is displayed, press and hold down the MENU key.
reOrDer Pool eXact EZ Photometer Specifications ® *Combined Chlorine DPD-3 Test requires Free Chlorine DPD-1 (486637) to be run first. R052814 For resellers and distributors - products sold in case quantities (12 units per case). For use in accordance with U.S. Patent No. 7,333,194, U.S.