Carrier WeatherExpert 48LC Series Installation Instructions Manual page 66

14-26 single package rooftop gas heat/electric cooling unit with puron (r-410a) refrigerant
Table of Contents

Advertisement

TERMINAL 53
LOW VOLTAGE
Motor
Voltage
6–10
Option
208/230
2
460
2
STD
575
2
208/230
2
460
2
MID
575
2
208/230
2
460
2
HIGH
575
2
208/230
2
460
2
ULTRA
575
2
Motor
Motor
Voltage
Option
P/N
208/230 HD58FE654 HK30WA371 131L9796
460
HD58FE654 HK30WA377 131L9864
STD
575
HD58FE577 HK30WA383 131N0227
208/230 HD60FK657 HK30WA373 131L9798
460
HD60FK657 HK30WA380 131L9867
MID
575
HD60FL576 HK30WA384 131N0229
208/230 HD62FK654 HK30WA374 131L9799
460
HD62FK654 HK30WA381 131L9868
HIGH
575
HD62FL576 HK30WA384 131N0229
208/230 HD64FK654 HK30WA375 131L9800
460
HD64FK654 HK30WA386 131L9869
ULTRA
575
HD64FL576 HK30WA388 131N0233
START
FLYING
DELAY
START
(sec)
Motor
Voltage
1–71
1–73
Option
208/230
2.0
[1]
460
2.0
[1]
STD
575
2.0
[1]
208/230
2.0
[1]
460
2.0
[1]
MID
575
2.0
[1]
208/230
2.0
[1]
460
2.0
[1]
HIGH
575
2.0
[1]
208/230
2.0
[1]
460
2.0
[1]
ULTRA
575
2.0
[1]
Table 28 — VFD Unit Parameters – 48LC**14 (cont)
TERMINAL 53
HIGH VOLTAGE
LOW REFERENCE
6–11
[10]
[10]
[10]
[10]
[10]
[10]
[10]
[10]
[10]
[10]
[10]
[10]
Table 29 — VFD Unit Parameters – 48LC**17
REGIONAL
SETTINGS
VFD
VFD
0–03
Carrier P/N
Mfr P/N
[1]
[1]
[1]
[1]
[1]
[1]
[1]
[1]
[1]
[1]
[1]
[1]
MOTOR
MIN SPEED FOR
THERMAL
FUNCTION (Hz)
PROTECTION
1–82
1–90
1.0
[4]
1.0
[4]
1.0
[4]
1.0
[4]
1.0
[4]
1.0
[4]
1.0
[4]
1.0
[4]
1.0
[4]
1.0
[4]
1.0
[4]
1.0
[4]
TERMINAL 53
TERMINAL 53
HIGH REFERENCE
6–14
6–15
0
[60]
0
[60]
0
[60]
0
[60]
0
[60]
0
[60]
0
[60]
0
[60]
0
[60]
0
[60]
0
[60]
0
[60]
GRID
MOTOR
MOTOR
TYPE
POWER
VOLTAGE
0–06
1–20
1–22
[102]
[10]
230
[122]
[10]
460
[132]
[11]
575
[102]
[14]
230
[122]
[14]
460
[132]
[14]
575
[102]
[15]
230
[122]
[15]
460
[132]
[15]
575
[102]
[16]
230
[122]
[16]
460
[132]
[16]
575
3–10 [0] 3–10 [1] 3–10 [2] 3–10 [3] 3–10 [4] 3–10 [5] 3–10 [6] 3–10 [7]
0%
56.64% 82.40%
0%
56.64% 82.40%
0%
56.64% 82.40%
0%
56.64% 82.40%
0%
56.64% 82.40%
0%
56.64% 82.40%
0%
56.64% 82.40%
0%
56.64% 82.40%
0%
56.64% 82.40%
0%
56.64% 82.40%
0%
56.64% 82.40%
0%
56.64% 82.40%
66
RESET
AUTO. RESTART
MODE
TIME (s)
14–20
14–21
[3]
600
[3]
600
[3]
600
[3]
600
[3]
600
[3]
600
[3]
600
[3]
600
[3]
600
[3]
600
[3]
600
[3]
600
MOTOR
MOTOR
CURRENT
FREQUENCY
(MUST-HOLD
(Hz)
AMPS)
1–23
1–24
60
9.2
60
4.2
60
4.9
60
21.2
60
9.7
60
7.2
60
28.0
60
13.7
60
8.9
60
37.3
60
16.9
60
12.6
PRESET REFERENCE
100%
100%
0%
100%
100%
0%
100%
100%
0%
100%
100%
0%
100%
100%
0%
100%
100%
0%
100%
100%
0%
100%
100%
0%
100%
100%
0%
100%
100%
0%
100%
100%
0%
100%
100%
0%
RFI
FILTER
14–50
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
MOTOR
NOMINAL
SPEED (RPM)
1–25
1735
1735
1710
1760
1760
1745
1760
1760
1750
1755
1755
1755
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%

Advertisement

Table of Contents
loading

Table of Contents