SAFETY INSTRUCTIONS
6
• Be sure the installation area does not deteriorate with age.
- If the base collapses, the unit could fall with it, causing
property damage, unit failure, and personal injury.
• Do not install the unit outdoor.
- It may cause damage to the unit.
• Use a vacuum pump or inert (nitrogen) gas when doing
leakage test or purging air. Do not compress air or oxygen and
do not use flammable gases.
- There is the risk of death, injury, fire or explosion.
• The appliance shall be stored in a well-ventilated area where
the room size corresponds to the room area as specified for
operation. (for R32)
• Ducts connected to an appliance shall not contain an ignition
source. (for R32)
• The appliance shall be stored in a room without continuously
operating ignition sources (for example: open flames, an
operating gas appliance or an operating electric heater.)
• Means for disconnection must be incorporated in the fixed
wiring in accordance with the wiring rules.
• This equipment shall be provided with a supply conductor
complying with the national regulation.
• Have all electric work done by a licensed electrician according
to "Electric Facility Engineering Standard" and "Interior Wire
Regulations" and the instructions given in this manual and
always use a special circuit.
- If the power source capacity is inadequate or electric work is
performed improperly, electric shock or fire may result.
• Always install a dedicated circuit and breaker.
- Improper wiring or installation may cause fire or electric
shock.
• Keep any required ventilation openings clear of obstruction.
• Mechanical connections shall be accessible for maintenance
purposes.