Technical Description; Installation - Dometic ECOLINE RH430STE Installation And Operating Manual

Minibar
Hide thumbs Also See for ECOLINE RH430STE:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 11

Technical description

Dometic reserves the right to change product appearance and product
specifications.
5
Technical description
The minibar can cool products to a maximum of 21 °C (RH430STE, RH440STE only)
or 19 °C (RH430NTE, RH440NTE only) under the ambient temperature and keep
them cool. A grid divider can be used to separate foodstuffs, e.g. bottles and
sweets.
Its cooling system is a non-wearing thermoelectric cooling.
Control element
No. in
Description
fig. 1, page 3
1
Temperature controller
6

Installation

The minibar is designed for freestanding installation, but can be built-in if the follow-
ing conditions are complied with to ensure satisfactory operation and maximum
cooling efficiency.
• The minibar must be levelled carefully to ensure proper function.
• The clearance between the minibar's back and the wall should be 20 mm or
more.
• Ventilation must be provided as shown in alternatives A, B, C or D (fig. 2,
page 3).
• The ventilation duct must at least measure 105 mm x the width of the minibar.
• Only the entire cooling unit must project into the ventilation duct as shown
(fig. 2, page 3).
• Air passing through the ventilation duct must not be preheated by any source of
heat.
• Ventilation grills, if used, must have openings of at least 200 cm² each.
• For glass door version, when ambient humidity is above 65 % in 25 °C ambient
temperature, moisture will condense on the door.
• The minibar can be fixed to the bottom of the furniture through its fixing feet using
screws of an appropriate length (fig. 3, page 3).
16
RH430, RH440
EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecoline rh430nteEcoline rh440steEcoline rh440nte

Table of Contents