Bellfires Room Divider Large 3 CF Preparation Manual

Hide thumbs Also See for Room Divider Large 3 CF:
Table of Contents

Advertisement

Quick Links

P P reparation manual
Room Divider Large 3 CF/LF/MF
Room Divider Large 3 L/R CF/LF/MF
Serial number:
Production date:

Advertisement

Table of Contents
loading

Summary of Contents for Bellfires Room Divider Large 3 CF

  • Page 1 P P reparation manual Room Divider Large 3 CF/LF/MF Room Divider Large 3 L/R CF/LF/MF Serial number: Production date:...
  • Page 2 Barbas Bellfires BV. This document could contain technical inaccuracies or typographical errors. Barbas Bellfires BV reserves the right to revise this document from time to time in the contents thereof.
  • Page 3: Table Of Contents

    Contents C C ontents About this document................5 How to work with this document....................5 Warnings and cautions used in this document................5 Related documentation........................ 5 Overview of the concentric flue system........... 6 Safety.......................7 Safety instructions for installation....................7 Requirements...................8 Requirements on the location......................
  • Page 4 Contents Available components for the concentric flue system......33 Appliance part list........................33 Bellfires - Muelink & Grol system Ø100 - Ø150................. 34 Bellfires - Muelink & Grol system Ø130 - Ø200................. 39 Poujoulat - DUOGAS system Ø100 - Ø150................42 Poujoulat - DUOGAS system Ø130 - Ø200................
  • Page 5: About This Document

    About this document About this document This document shows the necessary information to do these tasks on the : • Preparation for installation This document refers to the as 'the appliance'. This document is an essential part of your appliance. Read it carefully before you do work on the appliance. Keep it in a safe place. The original instructions of the document are in English.
  • Page 6: Overview Of The Concentric Flue System

    Overview of the concentric flue system Overview of the concentric flue system The concentric flue system provides the appliance with combustion air and removes the flue gases from the appliance. The concentric flue system is made of these items: Item Description Concentric flue The concentric flue is a pipe with an inner pipe.
  • Page 7: Safety

    Only use items in the installation that are specified in this manual and the related documents. • Only use the following brands for the installation of the concentric flue system: Manufacturer system Bellfires Muelink & Grol system Poujoulat DUOGAS system Ontop Metaloterm US system Jeremias/STB (STB = Schoorsteen...
  • Page 8: Requirements

    Requirements Requirements Requirements on the location • Never use combustible building materials for the fireplace. • Do not install the appliance against a flammable rear wall. • Install a nonflammable insulation plate of at least 12 mm between the appliance and the rear wall.
  • Page 9: Requirements On The Wall Outlet

    Requirements Minimum distance between the items L L ocation of any of the items(*) and the roof outlet At a lower positioned wall than the outlet At a higher sloping surface than the outlet (*) Items: • A ventilation opening that services an occupied room, a toilet or a bathroom. •...
  • Page 10: Requirements On The Concentric Flue System

    Requirements (**) If an obstruction protrudes at least 0.5 meter between the item and the outlet and the obstruction has a lenght of at least the recommended minimum distance, ignore the recommended minimum distance. 4 4 .5 Requirements on the concentric flue system Caution: •...
  • Page 11: Possibilities For A Concentric Flue System With A Roof Outlet

    Requirements 4 4 .5.1 Possibilities for a concentric flue system with a roof outlet Rigid concentric flue systems 10/11/12/13 4,28,(100) Concentric flue connection on appliance Ø100-Ø150 mm or Ø130-Ø200 mm Flue gas restriction plate width Concentric connection on the appli- Concentric connection on the appli- (min.
  • Page 12 Requirements 14,15 10/11/12/13 4,28,(100) Concentric flue connection on appliance Ø100-Ø150 mm or Ø130-Ø200 mm Flue gas restriction plate width Concentric connection Concentric connection (min. - max.) (min. - max.) (min. - max.) on the appliance is on the appliance is Ø100-Ø150 mm Ø130-Ø200 mm 1.0 - 11.0 m...
  • Page 13 Requirements F F lexible concentric flue systems 10/11/12/13 4,28,(100) Concentric flue connection on appliance Ø100-Ø150 mm or Ø130-Ø200 mm Flue gas restriction plate width Concentric connection on the appli- Concentric connection on the appli- (min. - max.) ance is Ø100-Ø150 mm ance is Ø130-Ø200 mm 2.0 - 4.0 m 30 mm...
  • Page 14 Requirements ≥45° 10/11/12/13 4,28,(100) Concentric flue connection on appliance Ø100-Ø150 mm or Ø130-Ø200 mm Flue gas restriction plate width Concentric connection Concentric connection (min. - max.) (min. - max.) (min. - max.) on the appliance is on the appliance is Ø100-Ø150 mm Ø130-Ø200 mm 1.0 - 11.0 m...
  • Page 15 Requirements 27,28,29 26,29 4,28,(100) Concentric flue connection on appliance Ø100-Ø150 mm or Ø130-Ø200 mm Flue gas restriction plate width Concentric connection on the appli- Concentric connection on the appli- (min. - max.) ance is Ø100-Ø150 mm ance is Ø130-Ø200 mm 2.0 - 4.0 m 30 mm 65 mm...
  • Page 16 Requirements ≥45° 27,28,29 26,29 4,28,(100) Concentric flue connection on appliance Ø100-Ø150 mm or Ø130-Ø200 mm Flue gas restriction plate width Concentric connection Concentric connection (min. - max.) (min. - max.) (min. - max.) on the appliance is on the appliance is Ø100-Ø150 mm Ø130-Ø200 mm 1.0 - 11.0 m...
  • Page 17: Possibilities For A Concentric Flue System With A Wall Outlet

    Requirements 4 4 .5.2 Possibilities for a concentric flue system with a wall outlet Install the wall outlet in the correct position as shown in the figure. The centre of the inner pipe must be positioned above the centre of the outer pipe. Rigid concentric flue systems 0.16 m 10/11/12/13...
  • Page 18 Requirements 0.16 m 110/111/113 4,128 Concentric flue connection on appliance Ø130-Ø200 mm Flue gas restriction plate width Concentric connection on the appliance (min. - max.) (min. - max.) is Ø130-Ø200 mm 1.0 - 2.0 m 0 - 2.6 m Room divider Large 3...
  • Page 19 Requirements 0.25 m 110/111/113 4,128 Concentric flue connection on appliance Ø130-Ø200 mm Flue gas restriction plate width Concentric connection on the appliance (min. - max.) (min. - max.) is Ø130-Ø200 mm 1.0 - 3.0 m 1.6 - 4.6 m Room divider Large 3...
  • Page 20 Requirements 0.16 m 110/111/ 110/113 110/111/113 4,128 Concentric flue connection on appliance Ø130-Ø200 mm Flue gas restriction plate width Concentric connection on (min. - max.) (min. - max.) (min. - max.) (min. - max.) the appliance is Ø130- Ø200 mm 0 - 0.5 m 0 - 0.5 m 0.5 - 1.0 m...
  • Page 21 Requirements 0.25 m 110/111/113 4,128 Concentric flue connection on appliance Ø130-Ø200 mm Flue gas restriction plate width Concentric connection on the appliance (min. - max.) (min. - max.) is Ø130-Ø200 mm 0 - 0.5 m 0 - 0.6 m 0.5 - 1.0 m 0 - 3.6 m 1.0 - 3.0 m 3.6 - 8.6 m...
  • Page 22: Technical Specification

    Technical specification Technical specification Roomdivider Large 3 - without frame Room divider Large 3...
  • Page 23: Roomdivider Large 3 - Hidden Door

    Technical specification 5 5 .2 Roomdivider Large 3 - hidden door With optional convection casing Room divider Large 3...
  • Page 24: Dimensions Of The Model With A 10 Cm Frame

    Technical specification 5 5 .3 Dimensions of the model with a 10 cm frame Label Dimension in mm Ø150/Ø200 Ø100/Ø130 1342,5 1356,5 1471,5 172,5 52,5 315,5 1267,5 Room divider Large 3...
  • Page 25: Roomdivider Large 3 - With Wall Support Frame

    Technical specification 5 5 .4 Roomdivider Large 3 - with wall support frame Room divider Large 3...
  • Page 26: Roomdivider Large 3 Left - Without Frame

    Technical specification 5 5 .5 Roomdivider Large 3 left - without frame Room divider Large 3...
  • Page 27: Roomdivider Large 3 Left - Hidden Door

    Technical specification 5 5 .6 Roomdivider Large 3 left - hidden door With optional convection casing Room divider Large 3...
  • Page 28: Roomdivider Large 3 Left - Hidden Door + 10 Cm Frame

    Technical specification 5 5 .7 Roomdivider Large 3 left - hidden door + 10 cm frame Room divider Large 3...
  • Page 29: Roomdivider Large 3 Right - Without Frame

    Technical specification 5 5 .8 Roomdivider Large 3 right - without frame Room divider Large 3...
  • Page 30: Roomdivider Large 3 Right- Hidden Door

    Technical specification 5 5 .9 Roomdivider Large 3 right- hidden door With optional convection casing Room divider Large 3...
  • Page 31: Roomdivider Large 3 Right - Hidden Door + 10 Cm Frame

    Technical specification 5 5 .10 Roomdivider Large 3 right - hidden door + 10 cm frame Room divider Large 3...
  • Page 32: Dimensions Of The Operating Unit

    Technical specification 5 5 .11 Dimensions of the operating unit Label Dimension in mm ± 350 5.12 Dimensions of the restriction plate Width of the delivered flue restriction plates in mm Concentric flue connection Ø100 - Ø150 Concentric flue connection Ø130 - Ø200 Roof-mounted outlet Horizontal wall outlet 30 mm...
  • Page 33: Available Components For The Concentric Flue System

    [Ø130 mm - Ø200 mm] (rigid and/or flexible) for the brand types mentioned below, has been approved in accordance with the European CE-norm for gas appliances and may therefore be used only with these systems. Table 1: Approved brands Manufacturer system Bellfires Muelink & Grol system Poujoulat DUOGAS system Ontop Metaloterm US system...
  • Page 34: Bellfires - Muelink & Grol System Ø100 - Ø150

    Available components for the concentric flue system 6 6 .2 Bellfires - Muelink & Grol system Ø100 - Ø150 Color (*) Application Bellfires Fig. Art./ Order Description stainless antr. rigid flex steel Twin-wall balanced flue 302289 ● ● pipe. L= 500 mm.
  • Page 35 Available components for the concentric flue system Color (*) Application Bellfires F F ig. Art./ Order Description stainless antr. rigid flex steel Twin-wall balanced flue 302297 ● ● elbow 90°. (ribbed) Twin-wall balanced flue 346239 elbow 90°. (segment) ● ●...
  • Page 36 Available components for the concentric flue system Color (*) Application Bellfires F F ig. Art./ Order Description stainless antr. rigid flex steel Vertical (roof) termina- 302295 tion kit, L= 1360 mm. ● ● ● ● ANTHRACITE Adjustable roof flash- 302212 ing.
  • Page 37 Available components for the concentric flue system Color (*) Application Bellfires F F ig. Art./ Order Description stainless antr. rigid flex steel 302215 Wall strap. ● ● ● Set of ceiling finishing 302214 ● ● ● plates / Fire stops.
  • Page 38 Available components for the concentric flue system Color (*) Application Bellfires F F ig. Art./ Order Description stainless antr. rigid flex steel Hose clamp Ø150 mm. 304042 (Minimum 2 per con- ● ● nection) Vertical (roof) termina- tion kit, L = 610 mm.
  • Page 39: Bellfires - Muelink & Grol System Ø130 - Ø200

    Available components for the concentric flue system used to extract the flue gasses. The temperature classification of the flexible pipe must be at least T450. 6 6 .3 Bellfires - Muelink & Grol system Ø130 - Ø200 Color (*) Application Bellfires Fig.
  • Page 40 Available components for the concentric flue system Color (*) Application Bellfires F F ig. Art./ Order Description stainless antr. rigid flex steel Twin-wall balanced 302314 flue elbow 90°. (rib- ● ● bed) Twin-wall balanced 302315 flue elbow 45°. (rib- ●...
  • Page 41 Available components for the concentric flue system Color (*) Application Bellfires F F ig. Art./ Order Description stainless antr. rigid flex steel Silicone seal Ø200 302248 ● ● 302251 Wall strap. ● ● Set of ceiling fin- 302250 ishing plates / Fire ●...
  • Page 42: Poujoulat - Duogas System Ø100 - Ø150

    Available components for the concentric flue system Color (*) Application Bellfires F F ig. Art./ Order Description stainless antr. rigid flex steel Hose clamp Ø200 304046 mm. (Minimum 2 ● ● per connection) (*)Color • Stainless steel, polished • antr. : Anthracite or Black color lacquer, matt (**) Adjustable roof flashing for a slope >...
  • Page 43 Available components for the concentric flue system Poujoulat F F ig Art./ Order Description 34100441 Twin-wall balanced flue elbow 90°. 34100421 Twin-wall balanced flue elbow 45°. 34100411 Twin-wall balanced flue elbow 30°. 34100401 Twin-wall balanced flue elbow 15°. 34100654 Vertical (roof) termination kit, L= 140 mm . Roof flashing, suitable for a brick roof, with a roof pitch 45150171 of 15°- 30°.
  • Page 44 Available components for the concentric flue system Poujoulat F F ig Art./ Order Description Roof flashing, suitable for a tiled roof, with a roof pitch 45150173 of 30°- 45°. 45150169 Roof flashing for existing chimney or flat roof. Horizontal (wall) termination kit, L= min. 365 mm / max. 34100610 585 mm.
  • Page 45: Poujoulat - Duogas System Ø130 - Ø200

    Poujoulat F F ig Art./ Order Description 45150081 Floor support, (universal) Ø150 mm. Adapter: Bellfires Ø100-150 mm → Poujoulat DUOGAS 34100611 Ø100-150 mm (Appliance 100/150 → Poujoulat DUO- GAS 100/150) Adapter: Bellfires Ø130-200 mm → Poujoulat DUOGAS 34100614 Ø100-150 mm (Appliance 130/200 → Poujoulat DUO- GAS 100/150) Concentric reduction of Poujoulat DUOGAS Ø130-200...
  • Page 46 Available components for the concentric flue system Poujoulat F F ig Art./ Order Description 34130441 Twin-wall balanced flue elbow 90°. 34130421 Twin-wall balanced flue elbow 45°. 34130411 Twin-wall balanced flue elbow 30°. 34130401 Twin-wall balanced flue elbow 15°. Horizontal (wall) termination kit, L= min. 365 mm / max. 34130610 585 mm.
  • Page 47: Ontop - Metaloterm Us System Ø100 - Ø150

    Art./ Order Description 45200165 Roof support, (universal) Ø200 mm. 45200081 Floor support, (universal) Ø200 mm. Adapter: Bellfires Ø130-200 mm → Poujoulat DUOGAS 34130615 Ø130-200 mm (Appliance 1300/200 → Poujoulat DUO- GAS 130/200) Ontop - Metaloterm US system Ø100 - Ø150 Fig.
  • Page 48 Available components for the concentric flue system F F ig. Ontop Art. / Description Order No. USB 45 10 Twin-wall balanced flue elbow 45°. USB 30 10 Twin-wall balanced flue elbow 30°. USB 15 10 Twin-wall balanced flue elbow 15°. USDVC2 10 Vertical (roof) termination kit, L= 375 mm.
  • Page 49 Available components for the concentric flue system F F ig. Ontop Art. / Description Order No. Roof flashing - Aluminum - For existing chimney or flat USDPAL 10 roof. Horizontal (wall) termination kit, L= 475 mm (adjusta- USDHC5 10 ble). USKB 10 Locking band, quick-fastening.
  • Page 50 Available components for the concentric flue system F F ig. Ontop Art. / Description Order No. USSAN 10 Renovation set. USSAN1 10 Top of renovation set. USSAN2 10 Bottom renovation set. USKBS 10 Locking band, screw-fastening. USI 10 Concentric pipe with inspection panel, L= 250 mm. USEM 10 Concentric pipe with gauging orifice, L= 150 mm.
  • Page 51: Ontop - Metaloterm Us System Ø130 - Ø200

    Ontop - Metaloterm US system Ø130 - Ø200 Fig. Ontop Art. / Description Order No. Adapter for Bellfires appliances with Ø100-Ø150 mm USA 13 concentric connection. US 25 13 Twin-wall balanced flue pipe, L = 250 mm. US 50 13 Twin-wall balanced flue pipe.
  • Page 52 Available components for the concentric flue system F F ig. Ontop Art. / Description Order No. Telescopic twin-wall balanced flue pipe, L= min. 60 / USPP 13 max. 250 mm. USB 90 13 Twin-wall balanced flue elbow 90°. USB 45 13 Twin-wall balanced flue elbow 45°. USB 30 13 Twin-wall balanced flue elbow 30°.
  • Page 53 Available components for the concentric flue system F F ig. Ontop Art. / Description Order No. Adjustable roof flashing. Roof pitch 20° - 45°, with lead USLS 13 flashing. USDH 13 Roof flashing plate for roof pitch 5°- 30°. USDP 13 Roof flashing for existing chimney or flat roof.
  • Page 54 Available components for the concentric flue system F F ig. Ontop Art. / Description Order No. Set of ceiling finishing plates / Fire stops / Centering USCP 13 plates. USDQ 13 Roof support. USSAN 13 Renovation set. 125 USSAN1 13 Top of renovation set. 125 USSAN1 13 Bottom renovation set.
  • Page 55 Available components for the concentric flue system F F ig. Ontop Art. / Description Order No. USEM 13 Concentric pipe with gauging orifice, L= 150 mm. USBI 13 90° concentric bend with inspection panel. USR 13 Rosette smooth Ø200 mm. USMPG 13 Wall plate large Ø200 mm, square 350 mm.
  • Page 56: Jeremias/Stb - H-Twin System Ø100 - Ø150

    Available components for the concentric flue system 6 6 .8 Jeremias/STB - H-Twin system Ø100 - Ø150 Jeremias Fig. Art. / Order Description ATWINL 13 Twin-wall balanced flue pipe. L= 1000 mm. 100-150 ATWINL 14 Twin-wall balanced flue pipe. L= 500 mm. 100-150 ATWINL 15 Twin-wall balanced flue pipe.
  • Page 57 Available components for the concentric flue system Jeremias F F ig. Art. / Order Description ATWIN 17 Twin-wall balanced flue elbow 30°. 100-150 ATWIN 18 Twin-wall balanced flue elbow 45°. 100-150 ATWIN 60 Twin-wall balanced flue elbow 90°. 100-150 ATWIN 60F Twin-wall balanced flue elbow 90°...
  • Page 58 Available components for the concentric flue system Jeremias F F ig. Art. / Order Description ATWIN 92 Roof termination - short with pipe, L = 300 mm, Verti- 100-150 cal. ATWIN Roof termination, with pipe, L = 495 mm, Vertical, with 92pe roof flashing for existing chimney or flat roof.
  • Page 59 Available components for the concentric flue system Jeremias F F ig. Art. / Order Description A681 Horizontal (wall) termination kit, L= 495 mm (horizontal- 100-150 ly adjustable), including one set of wall spacer plates. H-TWIN 752 Concentric T-piece with gauging orifice. Inspection 100-150 panel with cover cap and condensation-opening.
  • Page 60: Jeremias/Stb - H-Twin System Ø130 - Ø200

    Available components for the concentric flue system 6 6 .9 Jeremias/STB - H-Twin system Ø130 - Ø200 Jeremias Fig. Art. / Order Description ATWINL 13 Twin-wall balanced flue pipe. L= 1000 mm. 130-200 ATWINL 14 Twin-wall balanced flue pipe. L= 500 mm. 130-200 ATWINL 15 Twin-wall balanced flue pipe.
  • Page 61 Available components for the concentric flue system Jeremias F F ig. Art. / Order Description ATWIN 17 Twin-wall balanced flue elbow 30°. 130-200 ATWIN 18 Twin-wall balanced flue elbow 45°. 130-200 ATWIN 60 Twin-wall balanced flue elbow 90°. 130-200 ATWIN 60F Twin-wall balanced flue elbow 90°...
  • Page 62: Jeremias - Twin-Gas System Ø100 - Ø150

    Jeremias - TWIN-GAS system Ø100 - Ø150 Jeremias Fig. Art. / Order Description Bellfires Appliance connection / Adapter Bellfires TWG1634 Ø100/150 mm → Jeremias TWIN-GAS Ø100/150 mm L 100-150 = 160 mm Including locking band (2x). Room divider Large 3...
  • Page 63 Available components for the concentric flue system Jeremias F F ig. Art. / Order Description TWG13 Twin-wall balanced flue pipe, L = 1000 mm Including 100-150 locking band. TWG14 Twin-wall balanced flue pipe, L = 500 mm Including 100-150 locking band. TWG15 Twin-wall balanced flue pipe, L = 250 mm Including 100-150...
  • Page 64 Available components for the concentric flue system Jeremias F F ig. Art. / Order Description TWG17 Twin-wall balanced flue elbow 30°. Including locking 100-150 band. TWG18 Twin-wall balanced flue elbow 45°. Including locking 100-150 band. TWG60 Twin-wall balanced flue elbow 90°. Including locking 100-150 band.
  • Page 65 Available components for the concentric flue system Jeremias F F ig. Art. / Order Description Roof flashing with a roof pitch of 26° - 35° with flex. alu- TW38 150 flashing and storm collar. Roof flashing with a roof pitch of 36° - 45° with flex. alu- TW54 150 flashing and storm collar.
  • Page 66 Available components for the concentric flue system Jeremias F F ig. Art. / Order Description Extension pieces for the wall strap ZUWA704 L= 250 WA891250 Extension pieces for the wall strap ZUWA704 L= 400 ZUWA706 mm, WA = 50 - 360 mm. ZUDA074 Set of ceiling finishing plates / Fire stops for a flat roof : 0°.
  • Page 67 Available components for the concentric flue system Jeremias F F ig. Art. / Order Description TWG1732 Chimney-/flat roof-/ceiling - plate with adapter: Ø100 100-150 rigid/flex. to TWIN- GAS . TWG317 Concentric T-piece 90°. Including locking band. 100-150 TWG51 Concentric pipe with gauging orifice L= 200 mm. In- 100-150 cluding locking band.
  • Page 68: Jeremias - Twin-Gas System Ø130 - Ø200

    6.11 Jeremias - TWIN-GAS system Ø130 - Ø200 Jeremias Fig. Art. / Order Description Bellfires Appliance connection / Adapter Bellfires TWG1634 Ø130/200 mm → Jeremias TWIN-GAS Ø130/200 mm L 130-200 = 160 mm Including locking band (2x). TWG13 Twin-wall balanced flue pipe, L = 1000 mm Including 130-200 locking band.
  • Page 69 Available components for the concentric flue system Jeremias F F ig. Art. / Order Description TWG15 Twin-wall balanced flue pipe, L = 250 mm Including 130-200 locking band. TWG1801 Twin-wall balanced flue pipe, L = 1000 mm with 4 130-200 spacer brackets on the outside Including locking band.
  • Page 70 Available components for the concentric flue system Jeremias F F ig. Art. / Order Description TWG1786 Twin-wall balanced flue elbow 90° - with support leg In- 130-200 cluding locking band and sealing cap under. Twin-wall balanced flue elbow 90° - short - eccentric. TWG1676 Especially for connection to a wall termination 130-200...
  • Page 71 Available components for the concentric flue system Jeremias F F ig. Art. / Order Description Roof flashing for existing chimney or flat roof with storm TW52 200 collar. KL72 200 Storm collar (spare part). TWG1619 Wall termination kit, L= 600 mm (horizontal) Adjustable. 130-200 Incl.
  • Page 72 Available components for the concentric flue system Jeremias F F ig. Art. / Order Description ZUDA99V Set of ceiling finishing plates / Fire stops for a pitched roof : 0° - 30°. ZUDA98V Set of ceiling finishing plates / Fire stops for a pitched roof : 31°...
  • Page 73 Available components for the concentric flue system Jeremias F F ig. Art. / Order Description TWG10 Concentric pipe, L= 300 mm with cleaning opening/ 130-200 inspection panel. Including locking band. TWG19 Concentric elbow 90° with cleaning opening/inspection 130-200 panel. Including locking band. TWG05 Base plate/Cover-under with 2x ½”...
  • Page 74: Modinox - Pla System Ø100 - Ø153

    6.12 Modinox - PLA system Ø100 - Ø153 Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Bellfires appli- ance connec- tion: Adapter Bellfires Ø100/150 mm 2PLAMAFM100BEL ● ● → Modinox Ø100/153 mm. L= 230 mm.
  • Page 75 Available components for the concentric flue system Color (*) Application F F ig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Twin-wall bal- anced flue 2PLAELDR100500 ● ● pipe, L= 500 mm., INOX Twin-wall bal- anced flue 2PLAELDR100500NO pipe, L= 500 ●...
  • Page 76 Available components for the concentric flue system Color (*) Application F F ig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Twin-wall bal- anced flue el- 2PLACO30100 ● ● bow 30°, IN- Twin-wall bal- anced flue el- 2PLACO30100NO ●...
  • Page 77 Available components for the concentric flue system Color (*) Application F F ig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Collar for roof 2DIVCSOL153 flashing, IN- ● ● Collar for roof 2DIVCSOL153NO flashing, IN- ● ● OX - BLACK Sealing ring 2DIVJOCO155 for collar roof...
  • Page 78 Available components for the concentric flue system Color (*) Application F F ig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Roof flashing for existing 2DIVSOIN150 ● ● chimney or flat roof, INOX Roof flashing for existing 2DIVSOIN150NO chimney or ●...
  • Page 79 Available components for the concentric flue system Color (*) Application F F ig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Set of ceiling finishing 24 2PLACOCF100 ● ● plates / Fire stops Ceiling finish- ing plate with 24 2PLAPVEN100 ●...
  • Page 80 Available components for the concentric flue system Color (*) Application F F ig. Modinox Art./ Order No. Description stainles antr. rigid flex steel 36 2PLACTOS100 Roof strap ● ● Clearance 36 2PLAEPDS100 roof/floor pas- ● ● sage Adapter Modi- nox PLA → Flexible pipe, with chimney 2PLAADA71002020...
  • Page 81 Available components for the concentric flue system Color (*) Application F F ig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Adapter Modi- nox PLA → Flexible pipe, with chimney 2PLAADA71003030 ● ● ● bottom finish- ing plate 300x300mm, INOX Adapter Modi-...
  • Page 82 Available components for the concentric flue system Color (*) Application F F ig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Adapter Flexi- ble pipe → Modinox PLA, with chimney 2PLAADA61002020 ● ● ● top finishing plate 200x200mm, INOX Adapter Flexi- ble pipe →...
  • Page 83 Available components for the concentric flue system Color (*) Application F F ig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Insulation kit 2PTGKIRA100 + la ISORA for ● ● pente pitched roof passage Insulation kit ISORA for pitched roof passage, roof 2PTGKIRAV100 + la...
  • Page 84: Modinox - Pla System Ø130 - Ø200

    Adapter Bellfires Ø130/200 mm 2PLAMAFM130BELNO → Modinox ● ● Ø130/200 mm. L= 230 mm. INOX - BLACK 2PLAMAFM130100BEL Bellfires appli- ance connec- tion: Adapter Bellfires Ø130/200 mm ● ● → Modinox Ø100/153 mm. L= 180 mm. INOX 2PLAMAFM130100BEL...
  • Page 85 Available components for the concentric flue system Color (*) Application F F ig. Modinox Art./ Order No. Description stainless antr. rigid flex steel 2PLAMAFM130100 Adapter Modi- nox PLA Ø130/200 mm → Modinox ● ● Ø100/153 mm. L= 225 mm. INOX 2PLAMAFM130100NO Adapter Modi- nox PLA...
  • Page 86 Available components for the concentric flue system Color (*) Application F F ig. Modinox Art./ Order No. Description stainless antr. rigid flex steel Telescopic twin-wall bal- anced flue 2PLAELRE130500 pipe, L= min. ● ● 300 / max. 500 mm., IN- 2PLAELRE130500NO Telescopic twin-wall bal-...
  • Page 87 Available components for the concentric flue system Color (*) Application F F ig. Modinox Art./ Order No. Description stainless antr. rigid flex steel Vertical (roof) termination 2PLACHAR130 ● ● cap, L= 360 mm, INOX Vertical (roof) termination 2PLACHAR130NO cap, L= 360 ●...
  • Page 88 Available components for the concentric flue system Color (*) Application F F ig. Modinox Art./ Order No. Description stainless antr. rigid flex steel Roof flashing, standard model, lead: 0,6mm thick, 2DIVS5PS200 ● ● for a roof pitch of 5°- 30°, with IN- OX cone Roof flashing, large tile mod-...
  • Page 89 Available components for the concentric flue system Color (*) Application F F ig. Modinox Art./ Order No. Description stainless antr. rigid flex steel Horizontal (wall) termina- tion kit, with 2PLATHOR130 rosettes, L= ● ● min. 580 mm / max. 780 mm. INOX Horizontal (wall) termina-...
  • Page 90 Available components for the concentric flue system Color (*) Application F F ig. Modinox Art./ Order No. Description stainless antr. rigid flex steel Rosette, IN- 2PLAROSA130BT ● ● Rosette, IN- 2PLAROSA130BTNO ● ● OX - BLACK Rosette, IN- 2PLAROSA130BTBL ● OX - WHITE Rosette with 4 2PLAROSA130...
  • Page 91 Available components for the concentric flue system Color (*) Application F F ig. Modinox Art./ Order No. Description stainless antr. rigid flex steel Clearance 136 2PLAEPDS130 roof/floor pas- ● ● sage 2PLAADA71302020 Adapter Modi- nox PLA → Flexible pipe, with chimney ●...
  • Page 92 Available components for the concentric flue system Color (*) Application F F ig. Modinox Art./ Order No. Description stainless antr. rigid flex steel 2PLAADA71303030 Adapter Modi- nox PLA → Flexible pipe, with chimney ● ● ● bottom finish- ing plate 300x300mm, INOX 2PLAADA71303030NO Adapter Modi-...
  • Page 93 Available components for the concentric flue system Color (*) Application F F ig. Modinox Art./ Order No. Description stainless antr. rigid flex steel 2PLAADA61302020 Adapter Flexi- ble pipe → Modinox PLA, with chimney ● ● ● top finishing plate 200x200mm, INOX 2PLAADA61302525 Adapter Flexi-...
  • Page 94 Available components for the concentric flue system Color (*) Application F F ig. Modinox Art./ Order No. Description stainless antr. rigid flex steel Insulation kit 2PTGKIRA130 + la ISORA for ● ● pente pitched roof passage Insulation kit ISORA for pitched roof passage, roof 2PTGKIRAV130 + la...
  • Page 95 Available components for the concentric flue system Room divider Large 3 9 9 5...
  • Page 96 Y Y our Bellfires dealer 002 - 14.06.2019 - 348550...

This manual is also suitable for:

Room divider large 3 lfRoom divider large 3 mfRoom divider large 3 l cfRoom divider large 3 l lfRoom divider large 3 l mfRoom divider large 3 r cf ... Show all

Table of Contents