Power supply unit with built-in power stages type msx+ or zmx+ (29 pages)
Summary of Contents for phytron phyMOTION POWM01.1
Page 1
Power Supply Modules POWM01.2 and POWM02.2 TRANSLATION OF THE ORIGINAL GERMAN MANUAL 2/2013 Manual MA 1273-A004 EN...
Page 2
We appreciate suggestions and criticisms for further improvement. Email address: doku@phytron.de Questions about the use of the product described in the manual that you cannot find answered here, please contact your representative of phytron (http://www.phytron.eu/) in your local agencies. MA 1273-A004 EN...
1 Legal Instructions This manual: Read this manual very carefully before mounting, installing and operating the device and if necessary further manuals related to this manual. Please pay special attention to instructions that are marked as follows: DANGER –...
Page 4
Manual POWM01 / POWM02 Observe the following safety instructions! Qualified personnel WARNING – Serious injury possible! Serious personal injury or serious damage to the machine and drives could be caused by insufficiently trained personnel! Without proper training and qualifications damage to devices and injury might result! - Design, installation and operation of systems may only be performed by qualified and trained personnel.
Page 5
Safety Instructions Further Manual This manual is an addition to the following main manual: “phyMOTION Modular Multi-axis Controller for Stepper Motors” - First, read the main manual and then continue with this manual. Intended use: The phyMOTION is designed for operating in a drive system.
3 POWM01 / POWM02 Module Overview POWM stands for “Power Module“. It includes the external power supply for the power stages (24 V to 70 V ) as well as the power supply for the I/Os and the limit switches (separate 24 V ).
Page 8
• Device address switch • Remote/Local switch • Reset button • Connection of an external phytron touch panel (projected 2012) The external supply must be designed for the required current (e.g. by the SPH 240-2410-24 power supply unit). MA 1273-A004 EN...
Page 9
Intermediate supply POWM02: Fig. 3: POWM02 Feed-in to the power supply: • 24 to 70 V supply voltage (for motors and generates internally the logic voltages) – 20 A max. • Optional electrically isolated 24 V for inputs/outputs, limit and reference switches Configuration: •...
4.2 Mechanical Data Dimension 100 x 100 mm without front panel Weight POWM01: 68 g / 90 g (without/with front panel) POWM02: 53 g / 86 g (without/with front panel) Mounting Plug-in module into the modular stepper motor controller...
Manual POWM01 / POWM02 4.3 Features POWM01 Features Power supply 24…70 V / 20 A max. (motor supply U +24 V (±20 %) electrical isolated / 5 A max. (I/O supply) Voltage range between 24...70 V and 24 V Current capacity 20 A max.
4.4 Features POWM02 If the total current of all modules in a voltage group (20 A) is exceeded, or if a voltage group has various voltages to begin with, the POWM02 module must be applied for the supply of the power stages and I/Os.
HOST interface) to Local (the controller is running in pure stand-alone mode with a sequential program). • Reset button for the resetting of the controller • Connection of an external phytron touch panel (e.g. Android-based tablet) MA 1273-A004 EN...
5 Installation 5.1 Mechanical Installation phytron always delivers the phyMOTION completely assembled in order to make sure you can start with the installation and the wiring right way. Further Manual Detailed information on this subject is in a supporting manual: “phyMOTION...
Page 16
Manual POWM01 / POWM02 WARNING – Serious injury from electric shock! During electrical installation cables, connectors, etc. can be live. Before starting wiring, make sure that none of the power supplies are connected to the primary side of the mains supply. Isolate the power supplies from the mains or remove the appropriate fuses.
5.1.1 Assembly Rules Observe the following when installing a POWM01/POWM02 module: POWM01 Each configuration starts with a POWM01 main supply and configuration module. Then mount a CPU module MCM01 which also contains a selectable host interface module. POWM01 and POWM02 Each supply module: - Can supply at maximum of 10 further modules with the internal logic voltage (5 V).
Manual POWM01 / POWM02 5.2 Electrical Installation Ensure sufficient bending radius of the cables during installation. Do not lay the cables in tension or bend them. We recommend labelling the mating connectors to prevent interchanging the connectors. If all the connections are made, the last step is to plug in the power supply to the mains. 5.2.1 Connectors - Overview Connector Number...
5.2.2 Pin Assignment POWM02 Here is the pin assignment for the POWM02 module: Fig. 4: Pin assignment POWM02 For wiring please use the above defined mating connectors. MA 1273-A004 EN...
Manual POWM01 / POWM02 5.2.3 Pin Assignment POWM01 Here is the pin assignment for the POWM01 module: Fig. 5: Pin Assignment POWM01 MA 1273-A004 EN...
Page 21
To use the USB interface please install the appropriate USB driver in advance before connecting the phyMOTION Install the USB drivers from the delivered phytron CD. Administrator authorizations are required for the driver installation. Use a USB cable with a maximum length of 2 m! If you want to test several USB devices, which are identical in construction, you should use the same USB port on the PC.
Page 22
Manual POWM01 / POWM02 Touch Panel Connection A terminal with touch functionality (e.g, Android-based tablet) can be connected to this interface. Fig. 8: 4 pin Western modular connector L flat oval 4p/4 K It is used e.g. for configuring and diagnosing the phyMOTION controller e.g.
6 Commissioning Please read the manual for basic commissioning information of the DIOM01 module: Further manual Detailed information on this subject is in a supporting manual: “phyMOTION Modular Multi-axis Controller for Stepper Motors” The programming environment phyLOGIC ToolBox is explained in the following manual:...
Manual POWM01 / POWM02 6.1 USB Driver Installation (Windows) • Insert the Phytron-CD and open the folder USB Driver by the Windows Explorer. Select the .exe program which goes with your system software and start it by double clicking. The following window is shown on the desktop after a successful installation: •...
6.2 DIP Coded Rotary Switch The DIP switch is used to set the bus address for systems such as RS 485 or CAN. Fig. 9: 16 stage DIP coded rotary switch: calibration 0...F 6.3 REMOTE/LOCAL Switch R/L The mode can be selected with the REMOTE/LOCAL switch: REMOTE: The controller is connected via an interface with the PC.
Manual POWM01 / POWM02 6.4 Diagnostic by LED Display The LEDs indicate the status of the power modules by colours and flashing: Fig. 10: Status LEDs LEDs left right off No power supply connected – green Ready, power supply available >...
6.5 Reset Button The reset button on the Remote/Local switch is recess mounted in order to prevent unintentional activation. The Reset resets any error messages. Waite time after removal of the reset signal: approx. 3 sec. MA 1273-A004 EN...
Manual POWM01 / POWM02 7 Parameterising the Module There is no parameterising for the POWM01/POWM02! For more information about parameters and programming of the phyMOTION see the following manual: Further manual Detailed information on this subject is in a supporting manual: “phyLOGIC Command Reference for the phyMOTION Controller”...
- If you want to use the phyMOTION™ after removing a module, the gap has to be sealed with a blanking plate before power supply is reconnected and switched on. - To send a module to phytron use ESD packaging only. 9 Version / Compatibility POWM01.2/POWM02.2 can NOT be used to replace POWM01.1/POWM02.1.
10 Warranty, Disclaimer and Registered Trademarks 10.1 Disclaimer Phytron GmbH has verified the contents of the manual to match with the hardware and software. However, errors and omissions are exempt and phytron GmbH assumes no responsibility for complete compliance. The information contained in this publication is reviewed regularly and any necessary corrections are included in subsequent editions.
Need help?
Do you have a question about the phyMOTION POWM01.1 and is the answer not in the manual?
Questions and answers