Calibrating The Printing Density - Sony UP-DF550 Manual

Digital film imager
Hide thumbs Also See for UP-DF550:
Table of Contents

Advertisement

Chart of the high tone range
The tone of the center of each box on the chart can be
changed to that of the boxes to the right or left of it as
shown in the chart.
The tone of
the border of
each box on
the chart
can be
changed to
that of the
borders
above or
below it on
the chart
The next darkest part
The darkest part
3 Display the selected number by pressing the G
or g button.
Display the selected number.
To reset to the default setting of the high
tone range
Display 75.
12
Display the SAVE GAMMA menu by pressing the
f button.
13
Press the EXEC button.
The adjusted values are stored for the gamma curve
selected in step 4.
The unit returns to standby status and the remaining
amount of each type of film is displayed on the
LCD.
The unit operates according to the adjusted values
for the USER 3 gamma curve selected in step 4
until these values are modified.

Calibrating the Printing Density

The unit automatically calibrates the printing density
according to the density curve set.
Perform calibration for each type of blue thermal film
separately.
1,4
4
3
2,4
1
Press the MENU button.
2
Display the CALIBRATION menu by pressing the
F or f button.
3
Press the g button.
4
Select the desired calibration type by pressing the F
or f button.
To calibrate the unit for each film
1 Display FULL RANGE CAL by pressing the F
or f button.
4