Advertisement

Quick Links

(Certification N:o VTT 08 ATEX 066 or IECEx VTT 12.0009)
Thank you for choosing Slam Hornet
manual is to provide you all the necessary safety and product information to conduct your job
conveniently and without any risks for health and safety.
(Certification N:o VTT 08 ATEX 066 or IECEx VTT 12.0009)

Instructions for Safe Use

®
–portable work light for your job site. Purpose of this
Atexor Oy Seinäjoki • P.O.Box 89 • FIN-60101 Seinäjoki • FINLAND
www.atexor.com • Tel: +358 20 734 3250 • Trade Reg. No. 486.515 • VAT No. FI08370823

Advertisement

Table of Contents
loading

Summary of Contents for Atexor Slam Hornet 1x18W

  • Page 1: Instructions For Safe Use

    (Certification N:o VTT 08 ATEX 066 or IECEx VTT 12.0009) Atexor Oy Seinäjoki • P.O.Box 89 • FIN-60101 Seinäjoki • FINLAND www.atexor.com • Tel: +358 20 734 3250 • Trade Reg. No. 486.515 • VAT No. FI08370823...
  • Page 2: Table Of Contents

    2/16 Contents Instructions for Safe Use............................1 Introduction to Slam®Hornet ..........................3 1.1 Technical data ..............................3 1.2 Certification of equipment ..........................3 1.3 Standard unit construction ..........................5 Quality guaranteed ........................... 6 1.4.1 General ..............................6 1.4.2 Individual testing reports .......................... 7 Prior to use ...............................
  • Page 3: Introduction To Slam®Hornet

    3/16 Introduction to Slam®Hornet (Certification N:o VTT 08 ATEX 066 or IECEx VTT 12.0009) This instruction manual guides you through the process of selecting and adopting Slam®Hornet work light at your work site. The manual regards the following Slam®Hornet types: 1.1 Technical data Slam®Hornet 1x18W (later CSH118) Slam®Hornet 1x36W &...
  • Page 4 4/16 equipment is to used properly and according to its ratings, documentation and local applicable laws. Local, national certificates of these units may exist outside the region of EU. The aforementioned Slam®Hornet types are certified as follows. You may find brief explanation of the certificates beneath: Slam®Hornet luminaires with fluorescent tubes: II 2 GD...
  • Page 5: Standard Unit Construction

    5/16 Gb = Explosion Protection Level (EPL) marking for “HIGH” level of protection. Equipment for explosive GAS atmospheres, which is not a source of ignition in normal operation or during expected malfunctions. Explanation of marking for explosion hazardous area due to Dusts (e.g Ex t IIIC T 90 °C Db): Ex = Certified for use in explosion-hazardous areas tb = Explosion protection method “protection by enclosure”...
  • Page 6: Quality Guaranteed

     Slam®Click’n Fix 80 Single Bracket  Adjustable hanging straps To view options on accessories, please visit http://www.atexor.com for further study or call us directly +358 20 734 3250. 1.4 Quality guaranteed 1.4.1 General The Slam®Hornet series is designed, certified, manufactured and tested under ISO 9001:2008 quality system as well as additional requirements of the Directive 94/9/EC (ATEX) or IECEx scheme.
  • Page 7: Individual Testing Reports

    7/16 1.4.2 Individual testing reports Each Slam®unit has its own individual serial number and is provided with an original, individual testing report when leaving the factory. The year of manufacture is specified on the type label of the equipment. Following tests have been done for Slam®Hornet–units according to standards relating to portable luminaries for explosion hazardous area.
  • Page 8: Intended Purpose Of Equipment

    8/16 2.1.1 Intended purpose of equipment Please keep in mind what the actual application of equipment is. For example in case the equipment is to be moved when connected to the supply it needs to be designed for that purpose. If the certification is mentioning “portable” it means that the equipment is suitable and tested for portable use.
  • Page 9: Temperature Class Of The Equipment

    9/16 2.1.4 Temperature class of the equipment Please observe the Ignition Temperature (IT) of the substance creating the explosion hazard at your site. Select the equipment based on IT of the substance. The temperature of the equipment must be lower than IT. The highest temperature of the equipment is specified by using Temperature Classes T1 to T6.
  • Page 10: Operating Instructions

    10/16 Operating instructions 3.1 Personnel The use of the equipment is to be controlled and accepted by the operator. The personnel using the unit have to be authorized by the operator or his representative. In case of further training of using the equipment please contact the local supplier of this equipment. 3.2 Visual Inspection of Slam®Hornet As for all equipment to be used inside explosion hazardous area it is recommended that before taking the unit into Ex –area, at least a visual re-inspection on the unit was taken and...
  • Page 11: Connection To The Supply

    3.5 Adding accessories to Slam® Hornet Atexor provides a number of different accessories but in case you afterwards want to add accessories of your own for the Slam®Hornet –unit, please note the following points: 1.
  • Page 12: Linking In Series

    12/16 3.6 Linking in series Certain Slam®Hornet units may be equipped with Ex –certified socket in the factory. Sockets are considered as one option so they are added to the unit upon customer’s special request. In-built sockets are recommended when the illuminated area is notably large, complex or not enough wiring points are available.
  • Page 13: Inspection & Maintenance

    13/16 Slam®Hornet luminaires with LED modules: Supply Recommended Cable length Type of luminary Theoretical voltage max. Load number of =16 A (max.80 %) luminaries in series CSHLED2 (50 230 V 2900 W CSHLED2 (50 110 V 1400 W CSHLED2 (50 42 V 500 W CSHLED2 (50...
  • Page 14: Maintenance

    The surface resistance of the transparent parts has to be between 1 MΩ - 1 GΩ. Please contact Atexor Oy in case You need a simple measuring device, which is needed for measuring surface resistance of the PC-tube.
  • Page 15: More Information About The Use Of Electrical Apparatus For Explosive Gas Atmospheres

    15/16  Person who conducted the maintenance  Date of maintenance  Procedure of maintenance  Signature of person responsible accepting the maintenance 4.6 More information about the use of Electrical Apparatus for Explosive Gas Atmospheres Please observe the requirements of the valid standards of the day. Please study at least the following standards: EN/IEC 60079-14 (Electrical installations in hazardous areas) EN/IEC 60079-10 (Classification of hazardous areas)
  • Page 16: Helpdesk

    16/16 Helpdesk Under any doubt or question, please contact your local distributor or the manufacturer. Contact details: Phone: +358 20 734 3250 Fax: +358 20 734 3299 Email: info@atexor.com Web: http://www.atexor.com...