Offer of sale The items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any Order accepted by Parker Hannifin will be subject to our terms and conditions of sale, copy available on request.
Page 3
22,500 psi (1550 bar) and temperatures ranging from -45°C to 93°C (-50°F ® to 200°F). Already being used on thousands of applications worldwide, Parker is confident that Phastite can make your processes Smarter, Faster, Cleaner, Safer.
Page 4
(HP) Termination Male Straight - BSPP BSPP Tube ØE Bore O.D. F A/F ØE Please note: *Indicates standard Phastite ® connectors. For other connector shapes, please contact Parker. hread Tube Thread ØE Bore emale) O.D. (Male) Ø Tube Thread Tube ØE...
Page 5
Hose Assembly or Connector will not endanger persons or property. Parker provides a hose guard to protect the operator against hose burst. The hose connections are connected to the tool and pump with the use of a protective sleeve to avoid hose fitting disconnection. Detailed information is given in the Tool Assembly Section of this document.
Page 6
Contact Parker when in doubt as to the safety precautions and operations. If you have never been trained on high- pressure hydraulic safety, consult your distribution or service centre for a hydraulic safety course.
Page 7
Flame service, contact the Authorised Parker Service Centre in your area, or by calling 1-800-CPARKER. Care must be taken or weld spatter could burn through the hose and possibly ignite escaping fluid resulting in a catastrophic failure.
Page 8
Super Duplex seamless tubes for temperatures up to 93°C (200°F). These tables also show the minimum and maximum ® wall thickness of tubes that shall be used within the scope of the Parker Phastite design for each size of tube connector.
Page 11
Tubing ordering guidelines Tubing for use with Parker instrument fittings must be carefully ordered to insure adequate quality for good performance. Each purchase order must specify the material, nominal outside diametre, and wall thickness. Ordering to ASTM specifications insures that the tubing will be dimensionally, physically, and chemically within strict limits. Also, more stringent requirements may be added by the user.
Page 12
Phastite Assembly ® ® All tube pre-fabrication (cutting, bending and alignment) should be completed before Phastite is fully assembled ® (Failure to do so may result in the Phastite fitting being exposed to undesirable side loading). ® ii) Ensure that all other fittings in the tube-run are correctly assembled before Phastite is fully assembled.
Page 13
Note: Do not over deburr the O.D. of tubing. You may deburr the tubing with your choice of file(s) or utilize Parker’s IN-EX De-burring tool. (Figure 6) This tool can be used to deburr both the I.D. and O.D. of tubing sizes 1/8”...
Page 14
Minimum Tubing Lengths Phastool ® Tube O/D Length Inches Inches 2.52 2.56 Table 7 Figure 7 ® Phastool Tube O/D Length Inches Inches Note: Figure 7 illustrates the minimum straight length of 3.35 tubing needed ahead of any bend to fit into the presetting 3.31 tool.
Page 15
Tubemarkers ® The tubemarker (Figure 8) is a mandatory part of the process to properly assemble Phastite . It ensures adequate tube insertion and aids with inspecting for correct assembly. Proper tube insertion is essential. ® ® To achieve proper tube insertion, a range of Phastite tubemarkers are available.
Page 16
® Phastite connectors come in two types, permanent and termination. Permanent connectors are supplied completely assembled and disassembly of the collar should not be attempted. Termination connectors are also supplied completely assembled, however, collar and sealing sleeve can be removed from the assembly. The below connectors are suitable to ®...
Page 18
PC - Permanent Union Equal Cross Size Insert Part No Tool Fixed Jaw Moving Jaw Color Imperial Metric Phastool ® PHT-3A 4A PHT-3A 4A PH-4-PC 1/4” GREY Phastool ® PHT-3B 4A PHT-3B 4A Tri-Tool ® PHT-16 4B PHT-16 4A Phastool ®...
Page 19
Pumps and Tools are matched at the factory and MUST NOT be intermixed with other pumps or tools. The pumps count the amount of cycles and display critical end of life information. Phastite’s unique design provides a secure leak tight grip on the tubing. The connector make-up can be completed ®...
Page 20
Phastool ® For 1/4” (6mm), 3/8” (10mm), 1/2” (12mm), 5/8” (16mm) connections ® For the intermediate sizes of Phastite a larger portable tool is available for ease of installation. The portable tool (Figure 17) is supplied complete with a 12 ft (4 metre) hose and quick connectors.
Page 21
Preparing Phastool for Installation Selecting Phastool Inserts ® ® Quick and easy interchangeable tooling inserts allows the ® Phastool 3A - Portable ® Phastool to install connectors from sizes 1/4” to 5/8”. The When operating the Phastool 3A by hand it can be used in any orientation, however it is recommended that the insert selected is determined by the type of connector to be supplied boot is used.
Page 22
Selecting the Correct Pump for Phastool ® ® ® There are two pumps for installing Phastite connectors with the Phastool 3A and 3B: The Battery-Operated Pump (BP) and the Hand-Operated Pump (HP). Battery Operated Hydraulic Pump (BP Part Number: PH-3-BP Weight: 20 lbs (9 Kg) Reference Manual...
Page 23
Hand Operated Pump (HP Part Number: PH-HP Weight: 9 lbs (4 Kg) Reference Manual Document Number L1329 Rev B (Instruction Sheet) Hand Pump Setup 1. With the hand pump on a flat and stable work surface, Figure 30 unlatch the pump’s handle locking hook from the hoop. 2.
Page 24
Tube Marking and Installation of Connector in Assembley Tools ® *This procedure applies to all Phastool assembley tools. **If using a 3/8’’ tee connector, it is recommended to assemble the branch end first. 1. Select and prepare the tubing (pages 11 - 17). 2.
Page 25
11. When the tool and battery operated pump are ready to be of Parker SBEx training (Figure 38). packed away ensure that the pump mode lever is set to 3. Next, use the touch screen display to select from the ‘T’...
Page 26
Remove the inserts from the tool jaws and return them to their aperture in the tool travel case. b. Replace any damaged parts with Parker or d. Remove the boot, handles or vice plates from the tool and return them to their aperture in the tool travel case.
Page 27
® Selecting Inserts for the Tri-Tool ® The insert selected is determined by the type and size of the Phastite Tri-Tool ® Insert/Fitting Table connector to be assembled. Fixed Moving Style 1. There are two inserts to select – one for the fixed jaw and one for the moving jaw (Figure 47).
Page 28
Selecting the Correct Pump for the Tri-Tool ® ® There is only one pump for installing Phastite connectors ® with the Tri-Tool , this is the Mains Operated Pump (MP). Electric Hydraulic Pump (MP) Part Number: PH-16-MP Weight: 27 lbs (12 Kg) Reference Manual Document Number L2062 Rev.
Page 29
The operator Figure 57 will be prompted to enter the 4-digit passcode assigned to them upon successful completion of Parker SBEx training (Figure 56). 10. Next, use the touch screen display to select from the ®...
Page 30
14. Ensure that the oil fill cap is unscrewed by 1 – 2 turns to When the tool and mains operated pump are ready to be packed away ensure that the tool’s moving jaw is fully allow air to vent. retracted before removing the battery from the pump.
Page 31
Complex Tube Runs with Tri-Tool ® In order to facilitate the assembly of complex tube runs the Tri-Tool’s top shaft can be temporarily removed from the tool to provide access. 1. Use a pair of 30mm spanners, to hold the head of the top shaft while loosening the shaft nut. Remove the nut from the top shaft (Figure 62).
Page 32
HCT provides a record of chemical analysis with the raw material. • HCT relieves the user of Parker instrumentation fittings of any doubts. It acts as an assurance for today and for tomorrow. In addition to the documentation of chemical and physical properties, great care is taken throughout the manufacture of Parker’s connectors to ensure that potential stress...