Ohmic instruments UPM-DT-1 Operator's Manual

Ultrasound power meter

Advertisement

508 August St. Easton, MD 21601
Voice: (410) 820-5111
Fax: (410) 822-9633
www.ohmicinstruments.com
ULTRASOUND POWER METER
Models UPM-DT-1 & 10
OPERATOR'S MANUAL
1

Advertisement

Table of Contents
loading

Summary of Contents for Ohmic instruments UPM-DT-1

  • Page 1 508 August St. Easton, MD 21601 Voice: (410) 820-5111 Fax: (410) 822-9633 www.ohmicinstruments.com ULTRASOUND POWER METER Models UPM-DT-1 & 10 OPERATOR’S MANUAL...
  • Page 2 Company. Test forms may be copied as required by the original purchaser of the instrument. Information contained in this manual is believed to be accurate and reliable; however, no responsibility is assumed by Ohmic Instruments Company for its use. Ohmic reserves the right to supply its instruments with design changes and/or component substitutions that may not be documented in this manual.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Introduction..................................5 Unpacking the Power Meter ............................5 Replacement Parts ................................. 5 Selecting a Location for Operation ..........................6 Panel Controls and Display Indicator..........................6 Overview of Display Indicators ............................6 Operating Procedure ..............................7 Transporting the UPM-DT ............................... 7 General Operating Notes ..............................
  • Page 5: Introduction

    PDF format]  Carrying Case The rear panel of the UPM-DT Series Front view of UPM-DT-1 & 10. Shown is the The picture above shows the cone provides power and RS-232 computer / electronic balance, base assembly, test tank target assembly and transducer printer connections.
  • Page 6: Selecting A Location For Operation

    SELECTING A LOCATION FOR OPERATION  The UPM-DT-1 & 10 Power Meters should always be Near vibrating, rotating or reciprocating equipment used in environments free from excessive air currents,  Near magnetic fields or equipment that generate corrosives, vibration and temperature or humidity ex- magnetic fields tremes.
  • Page 7: Operating Procedure

    8. Allow 5 minutes for the scale to stabilize. With no ultrasonic power applied to the transducer, press Model UPM-DT-1 also has four ranges. When watts or either of the two O/T buttons to zero the unit. milliwatts are being measured, a Unit indicator below the display will illuminate.
  • Page 8: Calibration

    ON, this allows the balance to output ter. It is recommended that these units be returned to only numeric data for the RS-232 output (see page 10). Ohmic Instruments Company on a yearly basis for recali- OFF is the default setting. bration and recertification.
  • Page 9: Setting Date And Time

    SETTING DATE AND TIME The UPM-DT Series provides date and time data which Time is a feature which enables the balance to be set to can be viewed on a computer or printed out on an exter- the current time in either U.S. standards (12 hour peri- nal printer.
  • Page 10: Serial Computer/Printer Interface

    * External PRINT and/or TARE switches may be installed as shown. Momen- tary contact switches must be used. RS-232 INTERFACE: The UPM-DT-1 and UPM-DT-10 Output Formats: Data output can be initiated in one of Ultrasound Power Meters are equipped with a bi- three ways: 1) by pressing PRINT;...
  • Page 11: Shipping Instructions For Upm-Dt Series Power Meters

    5. Fasten the case lid onto the base, after making cer- COMMANDS ABOVE SHOULD BE USED. tain there is nothing loose inside. Ohmic Instruments Company assumes no responsibility 6. The package used for shipping should be strong and for the performance of these units if user changes to the large enough to allow for adequate packing material internal setup parameters or program are made.
  • Page 12: Specifications

    “Error 8.4” indicates underweight condition. This Read meter three times; readings should be within ± 1% will occur if the target is out of place on the UPM-DT-1. (for example, 14.504 to 14.796 for UPM-DT-1 and 14.52 No Display: 1) Check power and line cord; 2) Verify that to 14.80 for UPM-DT-10).
  • Page 13: Water, Tank Size, Transducer Placement & Temperature Considerations

    WATER, TANK SIZE, TRANSDUCER PLACEMENT & testing, particularly at higher power levels, will drive out TEMPERATURE CONSIDERATIONS dissolved air and air bubbles will be visible on surfaces in Water as a Measurement Medium: The measurements the tank. These bubbles can be gently brushed off. are to be performed in de-gassed water because ultra- sound propagation in water closely approximates that in Transducer Wetting and Placement: After tilting the...
  • Page 14: Theory Of Measuring Ultrasound Power With The Radiation Force Method

    THEORY OF MEASURING ULTRASOUND POWER WITH THE RADIATION FORCE METHOD Sound is a form of energy that sets the particles in the isonated medium into vibrational motion. The particles then possess a kinetic energy. If dP is the rate of the flow of this energy about an area dA, then the mean acoustic energy Eq.
  • Page 16 9. CONTINUOUS WAVE MODE CERTIFICATION (Average Power) WATTS ALLOWABLE WATTS WATTS ALLOWABLE WATTS POWER POWER DIFF. DIFF. SELECT RANGE SELECT RANGE 3.7 - 6.3 7.4 - 12.6 SAT. UNSAT. SAT. UNSAT. Average of 3 Readings Average of 3 Readings WATTS WATTS ALLOWABLE ALLOWABLE...
  • Page 17: Warranty

    1. Notify Ohmic Instruments Co. giving full details of the reliable. However, Ohmic Instruments Company assumes difficulty, and include the model, type, and serial no liability for its use.