Removing A Keypad To A Z-Wave Network; Factory Default Instructions; Notification Supported Report; Event Supported Report - ring Keypad Z-Wave Technical Manual

Table of Contents

Advertisement

Removing a Keypad to a Z-Wave Network

Exclusion Instructions
1. Initiate remove keypad flow in the Ring Alarm mobile application – Select the settings icon from
device details page and choose
"Remove Device"
2. Press and hold "1" key for three seconds
3. When the exclusion process in complete, the LED on the keypad will be solid blue, then go out.
4. Test the Keypad. Any button presses would not beep
Ring Base Station – Reset

Factory Default Instructions

1. Press and hold "5" key and using a pointed end of a paperclip, gently press and release
reset button via the reset pin hole found at the back of the keypad
2. Red network LED at the top left-hand corner will start to blink rapidly
3. Wait for the red LED to stop blinking then release the "5" key
Use this procedure only in the event that the network primary controller is missing or
otherwise inoperable.
Ring Keypad EU - Notification Information

Notification Supported Report:

Keypad supports Heat Alarm (0x04) and Home Security (0x07) and Power Management (0x08) and
System (0x09).

Event Supported Report:

Heat Alarm (0x04) : Clear State (0x00), OVERHEAT_DETECTED_UNKNOWN_LOCATION (0x02)
Home Security (0x07): Motion detection (0x08), State idle (0x00)
Power Management (0x08): State idle (0x00), Power has been applied (0x01), AC mains disconnected
(0x02), AC mains re-connected (0x03), Battery is charging (0x0C)
System (0x09): SYSTEM_SOFTWARE_FAILURE (0x04) with 0x55