Summary of Contents for Munters Comm-Box Series

  • Page 1 Comm-Box Manual for use and maintenance Comm-Box Internet Access Ag/MIS/UmGb-2595-05/18 Rev 1.0 P/N: 116597...
  • Page 2 Munters reserves the right to effect modifications to the apparatus in accordance with technical and legal developments. © Munters AB, 2017...
  • Page 3: Table Of Contents

    5.1.1.1 Farm Settings .......................... 17 5.1.1.2 Push Notifications ........................18 5.1.1.3 Local Users ..........................19 5.1.1.4 Data Collect..........................20 5.1.1.5 Activety Log ..........................20 5.1.2 House Scan Tab ..........................5.1.3 Diagnostics Tab ........................... 5.1.4 About Tab ............................. © Munters AB, 2017...
  • Page 4 5.2 User Settings ----------------------------------------------------------------------------------------------------------------------------------------------------------------------- 5.3 Software Upgrade ---------------------------------------------------------------------------------------------------------------------------------------------------------- WARRANTY ------------------------------------------------------------------------------------------------------------------------------------------------- 26 © Munters AB, 2017...
  • Page 5: Introduction

    The information contained herein has been prepared by qualified experts within Munters. While we believe the information is accurate and complete, we make no warranty or representation for any particular purposes. The information is offered in good faith and with the understanding that any use of the units or accessories in breach of the directions and warnings in this document is at the sole discretion and risk of the user.
  • Page 6: Introduction To The Comm-Box

    2 Introduction to the Comm-box Comm-Box provides complete access to your Munters controllers, including monitoring and control capabilities, from any device, anywhere. From one computer, tablet, or smartphone, you can manage an entire network. Cloud-based access to controllers • o Multiple, simultaneous users have network access Multiple communication pathways: •...
  • Page 7: Hardware Installation

    3 Hardware Installation This document details how to install Munters' Comm-Box unit. Installation consists of: Mounting the Comm-Box • Grounding • Connecting the Comm-Box to the Internet • Connecting the Comm-Box to a Peripheral Device • Connecting the Comm-Box to a Communicator •...
  • Page 8: Connecting The Comm-Box To The Internet

    If required, connect a screen or mouse to the Comm-Box (via the USB/HDMI ports). • 3.5 Connecting the Comm-Box to a Communicator Connect the Comm-Box to a Munters Communicator a standard USB cable (supplied with the • Communicator unit). NOTE Communicator requires the Communicator Serial Card (P/N: C-COMM-SERIAL) to support the Comm-Box.
  • Page 9: Connecting The Comm-Box To A Controller

    (22 AWG minimum). 3. Connect the cable shield wire to the controller ground strip. 4. Connect the wiring according to the following table: Port Color Wire Brown Green White Black Shield wire Figure 1: RS-232 Wiring © Munters AB, 2017...
  • Page 10 120 ohm terminator. 4. Connect the cable shield wire to the controller ground strip. 5. Connect the wiring according to the following table: Port Color Wire Brown Green White Black Shield wire Figure 2: RS-485 Wiring © Munters AB, 2017...
  • Page 11: Group Management

    3. User 3 is assigned access rights to Farm 1 and Farm 2. 4. In addition, User 1 is also assigned access rights to Farm 3, which is in an entirely different group. Any combination is possible. © Munters AB, 2017...
  • Page 12: Activating The Group

    NOTE If you decide not to connect now, you can always connect by clicking on the RotemNet Web Tab Farm Setting. As the Group administrator, you can invite other people to join the group as well as define their access rights. This is done in RotemNet Web itself. © Munters AB, 2017...
  • Page 13: Log In

    Figure 4: Create a New User Screen 2. Fill in all fields. 3. Click Create a User. The following screen appears. Figure 5: Sign In Screen (Example) NOTE To disconnect from the web, click the Disconnect button (refer to page 18). © Munters AB, 2017...
  • Page 14: Attaching The Farm To A Group

    Check the radio box next to the group to which you want to attach your farm and click Attach • to Group. Figure 7: Attach Farm to Group Screen To add an additional group, type in the Group Name and click Add a Group. • © Munters AB, 2017...
  • Page 15: Local Log In

    Password: "admin" NOTE The user name can not be changed. You can change the password after logging in. NOTE After logging in locally, you will need to log in to the Web (Log In, page 13). © Munters AB, 2017...
  • Page 16: Rotemnet Web

    Software Upgrade • After signing in, the following screen appears: Click on House to go to the Platinum Touch functions. • Click on to configure RotemNet Web functionality. • Click on to configure the user definitions. • © Munters AB, 2017...
  • Page 17: Rotemnet Web Functionality

    Local Users directly to the Comm-Box • Data Collect • Activety Log • 5.1.1.1 Farm Settings Use this screen to define functions related to Comm-Box’s connection to your farm. © Munters AB, 2017...
  • Page 18: Push Notifications

    • Com Port • Contact information (optional): This information will be used by Munters to contact users if • there is a need; for example to inform you of an update. The information will not be distributed to any outside parties what so ever.
  • Page 19: Local Users

    • Each user name and password is the same. For example, User 1’s password is User 1. User 2’s password is User 2. • The Farm Owner can edit these names, passwards, and to whom they are assigned. © Munters AB, 2017...
  • Page 20: Data Collect

    Cmd ID you can select filters to narrow down the results. 5.1.2 H OUSE The House Scan screen: Shows the results of the house scan. • Show the controller type and version used in each house. • © Munters AB, 2017...
  • Page 21: Diagnostics Tab

    5.1.3 D IAGNOSTICS Comm-Box includes a basic diagnostics package. On the Activation screen click Diagnostics. The following screen appears. • This screen: • o Supplies required data when speaking with technical support. o Enables a speed test. © Munters AB, 2017...
  • Page 22: About Tab

    5.1.4 A BOUT This screen displays the product and software version. Send this information to technical support in the even that you require assistance. The Support ID enables remote technical support from Munters or from your dealer. © Munters AB, 2017...
  • Page 23 Pressure Units o Wind Speed Units o Disable or enable standby by mode (if the latter, define the amount of time that needs to pass before the mode is activated). Click to save any changes. • © Munters AB, 2017...
  • Page 24 User updating using a flash drive: Click Update from a removable drive and choose the • required software version. NOTE If you did not place the disk on key in the USB port or if the disk does not contain a program, an error message appears. © Munters AB, 2017...
  • Page 25 © Munters AB, 2017...
  • Page 26 12 months of the delivery of the defective product. Munters has thirty days from the date of receipt in which to take action, and has the right to examine the product at the customer’s premises or at its own plant (carriage cost to be borne by the customer).
  • Page 27 The use of non-original spare parts or incorrect assembly exonerates the manufacturer from all liability. Requests for technical assistance and spare parts can be made directly to the nearest Munters office. A full list of contact details can be found on the back page of this manual.
  • Page 28 Munters Brasil Industria e Comercio Ltda, Phone +55 41 3317 5050, Canada Munters Corporation Lansing, Phone +1 517 676 7070, China Munters Air Treatment Equipment (Beijing) Co. Ltd, Phone +86 10 80 481 121, Denmark Munters A/S, Phone +45 9862 3311, India...