Bailey NIAO01 Instruction

Infi 90, analog output termination module

Advertisement

Quick Links

E96-438
®
®
Analog Output Termination Module
(NIAO01)
Process Control and
Automation Solutions
from Elsag Bailey Group

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NIAO01 and is the answer not in the manual?

Questions and answers

Summary of Contents for Bailey NIAO01

  • Page 1 E96-438 ® ® Analog Output Termination Module (NIAO01) Process Control and Automation Solutions from Elsag Bailey Group...
  • Page 2 The information contained in this document is subject to change without notice. Elsag Bailey, its affiliates, employees, and agents, and the authors and contributors to this publication specif- ically disclaim all liabilities and warranties, express and implied (including warranties of merchantability and...
  • Page 3 Output Termination Module provides an interface between the IMAOM01 Analog Output Module and eight analog out- puts. This product instruction explains how to install and use the NIAO01 Analog Output Termination Module. ® Registered trademark of Elsag Bailey Process Automation. I-E96-438A...
  • Page 4 ® List of Effective Pages Total number of pages in this instruction is 24, consisting of the following: Page No. Change Date Preface Original List of Effective Pages Original iii through vi Original 1-1 through 1-4 Original 2-1 through 2-7 Original Original 4-1 through 4-2...
  • Page 5 Safety Summary GENERAL Equipment Environment WARNINGS All components, whether in transportation, operation or storage, must be in a noncorrosive environment. Electrical Shock Hazard During Maintenance Disconnect power or take precautions to insure that contact with energized parts is avoided when servicing. SPECIFIC Remove modules (slave, master or termination) from their assigned CAUTIONS...
  • Page 6 ® Sommaire de Sécurité AVERTISSEMENTS Environnement de l’équipement D’ORDRE Ne pas soumettre les composants à une atmosphère corrosive lors GÉNÉRAL du transport, de l’entreposage ou l’utilisation. Possibilité de chocs électriques durant l’entretien Débrancher l’alimentation ou prendre les précautions pour éviter tout contact avec des composants sous tension durant l’entretien.
  • Page 7: Table Of Contents

    Table of Contents Page SECTION 1 - INTRODUCTION ....................1-1 OVERVIEW ........................1-1 INTENDED USER ......................1-1 MODULE DESCRIPTION ....................1-2 INSTRUCTION CONTENT .....................1-2 HOW TO USE THIS MANUAL ..................1-2 REFERENCE DOCUMENTS..................1-2 GLOSSARY OF TERMS AND ABBREVIATIONS .............1-3 NOMENCLATURE ......................1-3 SPECIFICATIONS ......................1-3 SECTION 2 - INSTALLATION .....................2-1 INTRODUCTION......................2-1 SPECIAL HANDLING ....................2-1 UNPACKING AND INSPECTION ..................2-2...
  • Page 8 ® List of Figures Title Page 1-1. Example NIAO01 Termination Module Application ..........1-1 2-1. NIAO01 Termination Module Layout ..............2-2 2-2. Cable Connections....................2-4 2-3. NIAO01 Termination Module Terminal Assignments ..........2-7 2-4. Output Termination Example ................2-7 A-1.
  • Page 9: Section 1 - Introduction

    SECTION 1 - INTRODUCTION OVERVIEW The NIAO01 Analog Output Termination Module (IAO) is used in conjunction with the IMAOM01 Analog Output Module (AOM). The IAO termination module outputs eight channels of analog signals from the AOM module to field devices such as recorders, indicators, or any four to 20 milliamp, one to five VDC or zero to ten VDC devices.
  • Page 10: Module Description

    Details how to replace an IAO termination module. Procedures Support Services Describes the support services (spare parts, training, docu- mentation, etc.) available from Bailey Controls Company. Appendix A Contains data to connect the termination module to the analog output module. Appendix A shows the switch settings and cabling requirements for the analog output module.
  • Page 11: Glossary Of Terms And Abbreviations

    Cable retaining kit. Used for interfacing round cable connection to TMU unit. SPECIFICATIONS Refer to Table for the specifications of the IAO termination module. ® Registered trademarks of Elsag Bailey Process Automation. GLOSSARY OF TERMS AND ABBREVIATIONS I-E96-438A 1 - 3...
  • Page 12: Niao01 Termination Module Specifications

    Air Quality Bailey equipment should be operated and stored in a noncorrosive environment. Cooling Requirements No cooling is necessary when used in Bailey cabinets and operated within stated environmental limits. Certification CSA certified for use as process control equipment in an ordinary (nonhazardous) location.
  • Page 13: Section 2 - Installation

    SECTION 2 - INSTALLATION INTRODUCTION This section explains how to configure and install the NIAO01 Analog Output Termination Module. Read, understand and complete the steps in the order they appear before using the IAO termination module. SPECIAL HANDLING Observe these steps when handling electronic circuitry:...
  • Page 14: Unpacking And Inspection

    ® UNPACKING AND INSPECTION 1. Examine the hardware immediately for shipping damage. 2. Notify the nearest Bailey Controls Company sales office of any such damage. 3. File a claim for any damage with the transportation com- pany that handled the shipment.
  • Page 15: Dipswitch Configuration

    (analog outputs one through eight respectively). Refer to Appendix A to find the dipswitch settings for the analog output module. Table 2-1. NIAO01 Termination Module Dipswitch Settings Application/ Dipswitch Position Binary Dipswitch Signal Type...
  • Page 16: Cable Installation

    INSTALLATION ® NKTM01 NKTU02/12 IMAOM01 NIAO01 T00714A Figure 2-2. Cable Connections Table 2-2. NIAO01 Termination Module Cable Applications Nomenclature/ Maximum Length Application Connector Description meters (feet) NKTM01 (ribbon cable) 30 (100) Connects IAO P1 on termination unit to termination module to...
  • Page 17: Nktu02 And Nktu12 Cables

    INSTALLATION 2. Insert the other end of the cable into the termination mounting unit (TMU) backplane slot assigned to the IAO termi- nation module. The cable should latch securely in place. Card edge connector P1 of the IAO termination module connects to this end of the cable.
  • Page 18: Terminal Wiring

    INSTALLATION ® Terminal Wiring It is strongly recommended that all power (cabinet, I/O, etc.) be turned off before doing any termination module wiring. Failure CAUTION to do so could result in equipment damage. Do not apply power until all connections are verified. II est fortement recommand, que toutes les alimentations (arm- oire, E/S, etc.) soient coupées avant d'effectuer quelque rac- cord que ce soit sur un carte de raccordement.
  • Page 19: Niao01 Termination Module Terminal Assignments

    INSTALLATION The NIAO01 termination module is ready for operation if: 1. The fuses are installed. 2. The cable is installed and verified. 3. All field wiring is complete. 4. Power is connected and applied to the IAO termination module. TERMINAL NUMBER –...
  • Page 20: Section 3 - Maintenance

    SECTION 3 - MAINTENANCE INTRODUCTION The analog output termination module requires limited main- tenance. This section contains a maintenance schedule. MAINTENANCE SCHEDULE Execute the tasks in Table at the specified intervals. Table 3-1. Maintenance Schedule Task Interval Clean and tighten all power and field wiring connections.
  • Page 21: Section 4 - Repair/Replacement Procedures

    SECTION 4 - REPAIR/REPLACEMENT PROCEDURES INTRODUCTION This section explains the replacement procedures for the ana- log output termination module. MODULE REPLACEMENT PROCEDURES If an IAO termination module is faulty, replace it with a new one. To replace an IAO termination module: It is strongly recommended that all power (cabinet, I/O, etc.) be turned off before doing any termination module wiring.
  • Page 22: Fuse Replacement Procedures

    REPAIR/REPLACEMENT PROCEDURES ® 9. Verify proper wiring connections to the replacement IAO termination module. 10. Insert the replacement IAO module until it locks securely into place. 11. Install (snap on) the front cover on the replacement IAO ter- mination module. 12.
  • Page 23: Section 5 - Support Services

    SECTION 5 - SUPPORT SERVICES INTRODUCTION Bailey Controls Company is ready to help in the use, applica- tion and repair of its products. Contact the nearest sales office to make requests for sales, applications, installation, repair, overhaul and maintenance contract services.
  • Page 24: Analog Output Module Layout

    APPENDIX A - IMAOM01 ANALOG OUTPUT MODULE INTRODUCTION The IMAOM01 Analog Output Module produces eight analog output signals in response to messages received over the mod- ule bus from other modules in the system. Figure shows the dipswitch and jumper locations on the AOM module.
  • Page 25: Appendix A - Imaom01 Analog Output Module

    IMAOM01 ANALOG OUTPUT MODULE ® Table A-1. Example AOM Module Address Switch Settings (S2) Dipswitch Position (Binary Value) Address Example (16) NOTE: 0 = OPEN or OFF, 1 = CLOSED or ON. Table A-2. Jumper Settings Signal Jumper E3 Jumpers E6 - E13 4 - 20 mA 1 - 5 VDC T00718A...
  • Page 26 Installing the termination module........ 2-5 Instruction content ............1-2 Intended user ............. 1-1 Technical documentation ..........5-1 Terminal Assignments NIAO01..........2-7 Wiring ..............2-6 Jumper settings ............A-2 Training ...............5-1 Layout Unpacking and inspection...........2-2 AOM module............A-1 NIAO01 termination module ......... 2-2 I-E96-438A Index - 1...
  • Page 27 Telefax 39-10-6582-941 Telephone 49-69-799-0 Telefax 65-292-9011 Telefax 49-69-799-2406 Form I-E96-438A Litho in U.S.A. 393 Copyright © 1993 by Elsag Bailey Process Automation, As An Unpublished Work ® Registered Trademark of Elsag Bailey Process Automation ™ Trademark of Elsag Bailey Process Automation...

Table of Contents