9.2
MAINTENANCE EVERY 100000 CYCLES
Required time 45 minutes.
The skilled technician should take all the necessary precautions relating to safety measures to insulate the
machine from the mains. Inform the manager responsible about timing and the need to operate on the
electric systems of the premises before proceeding to avoid interruptions and complete all procedures eas-
ily without further requests. Before proceeding, remove all perimeter coverings and make sure there are no
damages or leakages.
Check for any damaged wires or cabling.
Check for noisy motor.
Check for cracks on beans hopper.
Replace grinder blades.
Replace the clump crusher. Bend the flaps and be sure they are really well opened with an angle of
approximately 30 degrees.
Check for wear on product button selection.
Check ON/OFF switch.
Check LCD display.