Whirlpool GXW6530DX Product Dimensions
Whirlpool GXW6530DX Product Dimensions

Whirlpool GXW6530DX Product Dimensions

Whirlpool 30" and 36" wall-mount canopy range hood

Advertisement

Quick Links

PRODUCT MODEL NUMBERS
GXW6530DX
GXW6536DX
ELECTRICAL REQUIREMENTS
• A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.
VENTING REQUIREMENTS
This canopy hood is factory set for venting through the roof or wall.
A 6" (15.2 cm) round vent system is needed for installation (not included). The
hood exhaust opening is 6" (15.2 cm) round.
NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and
air turbulence that greatly reduce performance.
Vent system can terminate either through the roof or wall. To vent through a
wall, a 90° elbow is needed.
Rear discharge
A 90° elbow may be installed immediately above the hood.
For Non-Vented (recirculating) Installations
If it is not possible to vent cooking fumes and vapors to the outside, the hood
can be used in the non-vented (recirculating) version, fitting a charcoal filter and
the deflector. Fumes and vapors are recycled through the top grille.
Roof Venting
A
B
A. Roof cap
B. 6" (15.2 cm)
round vent
PRODUCT DIMENSIONS
10 "
(27.6 cm)
20"
(50.8 cm)
Because Whirlpool Corporation policy includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.
30" and 36" (76.2 cm and 91.4 cm) Wall-Mount
®
Canopy Range Hood
Wall Venting
Non-vented
(recirculating)
B
B
A
A. Wall cap
A. Deflector
B. 6" (15.2 cm)
B. 6" (15.2 cm)
round vent
round vent
13
"
(33.5 cm)
30" (76.2 cm) or
36" (91.4 cm)
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet
(meters) for each vent piece used in the system.
Vent Piece
45° elbow
90° elbow
Maximum equivalent vent length is 35 ft (10.7 m).
Example vent system
90 elbow
A
2 ft
(0.6 m)
The following example falls within the maximum recommended vent
length of 35 ft (10.7 m).
1 - 90° elbow
1 - wall cap
8 ft (2.4 m) straight
Length of system
17
" (43.7 cm)
*For non-vented (recirculating) installations
**For vented installations
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Round
2.5 ft (0.8 m)
5.0 ft (1.5 m)
Wall cap
6 ft (1.8 m)
= 5.0 ft (1.5 m)
= 0.0 ft (0.0 m)
= 8.0 ft (2.4 m)
= 13.0 ft (3.9 m)
**27 " (68.9 cm) min.
**41 " (104.5 cm) max.
*27 " (68.9 cm) min.
*45 " (115.6 cm) max.
Page 1 of 2
Ref. W10292167C
10/26/10

Advertisement

loading

Summary of Contents for Whirlpool GXW6530DX

  • Page 1 (50.8 cm) 30" (76.2 cm) or 36" (91.4 cm) Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice. Calculating Vent System Length To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.
  • Page 2 Centerline *For non-vented (recirculating) installations Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice. IMPORTANT: For vented installations, the chimneys can be adjusted for ceilings between 7’...

This manual is also suitable for:

Gxw6536dx