Truck to Terminal Safety Communications
Model Speci c Functions
Pressing the "View History" button will display details on the last load
recorded with a date and time stamp. Prior load details can also be
viewed using the down and up buttons to scroll through them.

Capacity

The Super T.I.M. stores the capacity limits of each tank truck
compartment and communicates this to the terminal during loading for
improved over ll prevention. The allowable compartment volume is by
default the same as the capacity limit on the truck identi cation plate.
With the programmer, carriers have the option reducing the allowable
capacities to suit their particular needs.
The capacity values for each compartment can be updated, by pressing
the "Capacity" button.
1. Using the down and up buttons, scroll to nd the parameter to
be updated/recorded, and press "Edit".
2. Using the on-screen keyboard, enter the new value and press
"Enter" on the keyboard.
3. To exit the edit screen from the keyboard without making
changes, press the tab key (above the "Caps Lock" key).

Alternate T.I.M. ID

Terminals have the option of authorizing a load based on a xed Trailer
Identi cation Module number. The Super T.I.M. has additional reference
information available to simplify reporting.
Carriers can now associate their own Trailer ID with each Super T.I.M..
If programmed to the Super T.I.M., this additional information can be
read by the terminal during the loading process. The Alternate T.I.M. ID
number can be changed with the "Capacity" button and associated
instructions. The Alternate T.I.M. ID is the rst item in the "Capacity"
parameter list, followed by other carrier speci c identi cation elds
(Contract number, Operating Service, Driver ID).