Autonics BF4 Series Manual

Autonics BF4 Series Manual

Fiber optic amplifier

Advertisement

BF4 Series
High Reliability Of Fiber Optic Amplifier For Convenient Mounting

Features

● High speed response: max. 0.5ms
● Auto sensitivity setting (button setting)/external input sensitivity setting type
● External synchronization input, mutual interference protection, self-diagnosis
● Reverse power polarity and short-circuit (overcurrent) protection circuit
● Timer function: selectable none / 40ms OFF delay timer (fixed)
(standard type, remote sensitivity setting type only)
● Automatically selectable Light ON / Dark ON
● Precise detection of small target and easy to install in the complicated place
Please read "Safety Considerations" in operation
manual before using.

Ordering Information

BF 4 R P

Specifications

Model
Light source
Power supply
Current consumption
Operation mode
Control output
Protection circuit
Response time
Sensitivity setting
Indicator
Mutual interference prevention
Self-diagnosis output
Input of stop transmission function -
External synchronization function -
Remote sensitivity setting function -
Timer function
Insulation resistance
Noise immunity
Dielectric strength
Vibration
Shock
Ambient illumination
Environ-
Ambient temperature
ment
Ambient humidity
Material
Cable
Accessory
Approval
※ 1
Weight
※ 1: The weight includes packaging. The weight in parenthesis is for unit only.
※ The temperature or humidity mentioned in Environment indicates a non freezing or condensation environment.
-
E
Standard type
BF4RP
BF4GP
BF4R
Red LED
Green LED
Red LED
(660nm)
(525nm)
(660nm)
12-24VDCᜡ ±10% (ripple P-P: max.10%)
Max. 45mA
Light ON/Dark ON switching
NPN or PNP open collector output
● Load voltage: max. 30VDCᜡ ● Load current: max. 100mA
● Residual voltage - NPN: max. 1V (load current: 100mA), max. 0.4V (load current: 16mA) / PNP: max. 2.5V
Reverse polarity protection circuit, short-circuit (overcurrent) protection circuit
Max. 0.5ms (frequency 1), max. 0.7ms (frequency 2)
Sensitivity setting button (ON/OFF)
Control output indicator (OUT): red LED,
Stability indicator (STAB): green LED (turns ON at stable light ON/OFF level)
Built-in differential frequency mode (frequency 1 (normal mode): max. 0.5ms, frequency 2: max. 0.7ms)
ON state under unstable sensing (when the target stays for 300ms in unstable level),
ON state when control output is short-circuited
● Load voltage: max. 30VDCᜡ ● Load current: max. 50mA
● Residual voltage - NPN: max. 1V (load current: 50mA), max. 0.4V (load current: 16mA) / PNP: max. 2.5V
OFF delay (40ms)
Over 20MΩ (at 500VDC megger)
±240V the square wave noise (pulse width: 1㎲) by the noise simulator
1,000VAC 50/60Hz for 1 minute
1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours
500m/s² (approx. 50G) in each X, Y, Z direction for 3 times
Sunlight: max. 11000㏓, Incandescent lamp: max. 3000㏓ (received illumination)
-10 to 50℃, storage: -20 to 70℃
35 to 85% RH, storage:35 to 85% RH
Case: heat-resistance acrylonitrile butadiene styrene, cover: polycarbonate
Ø4mm, 4-wire, 2m
(AWG22, core diameter: 0.08mm, number of cores:
60, insulator out diameter: Ø1.25mm)
Mounting bracket, bolts, nuts
Approx. 120g (approx. 65g)
Fiber Optic Amplifier
No mark
Standard type
E
External synchronization input type
R
External input sensitivity setting type
No mark
NPN open collector output
P
PNP open collector output
R
Red LED
G
Green LED
4
Series
BF
Fiber Sensor
External synchronization
input type
BF4G
BF4R-E
BF4G-E
Green LED
Red LED
Green LED
(525nm)
(660nm)
(525nm)
Built-in
Built-in (gate/trigger)
-
-
Ø4mm, 6-wire, 2m
(AWG24, core diameter: 0.08mm, number of cores:
40, insulator out diameter: Ø1mm)
(A)
Photoelectric
Sensors
(B)
Fiber
Optic
Sensors
(C)
Door/Area
Sensors
(D)
Proximity
Sensors
(E)
Pressure
Sensors
(F)
Rotary
Encoders
(G)
Connectors/
Connector Cables/
Sensor Distribution
Boxes/ Sockets
(H)
Temperature
Controllers
(I)
SSRs / Power
Controllers
External input sensitivity
(J)
Counters
setting type
BF4R-R
BF4G-R
Red LED
Green LED
(K)
(660nm)
(525nm)
Timers
(L)
Panel
Meters
(M)
Tacho /
Speed / Pulse
Meters
(N)
Display
Units
(O)
Sensor
Controllers
(P)
Switching
Mode Power
Supplies
-
(Q)
-
Stepper Motors
& Drivers
Built-in
& Controllers
OFF delay (40ms)
(R)
Graphic/
Logic
Panels
(S)
Field
Network
Devices
(T)
Software
B-33

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BF4 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Autonics BF4 Series

  • Page 1 BF4 Series Fiber Optic Amplifier High Reliability Of Fiber Optic Amplifier For Convenient Mounting Photoelectric Sensors Features ● High speed response: max. 0.5ms Fiber ● Auto sensitivity setting (button setting)/external input sensitivity setting type Optic Sensors ● External synchronization input, mutual interference protection, self-diagnosis ●...
  • Page 2 BF4 Series Feature Data Through-beam type Diffuse reflective type ● Measurement: BF4 (- )+ FT-420-10 ● Measurement: BF4 (- ) + FD-620-10 Parallel shifting characteristic Sensing area characteristic Measuring method Data Measuring method Data ℓ Receiver ℓ -100 -200 ℓ...
  • Page 3 Fiber Optic Amplifier Connections Photoelectric ● BF4R / BF4G ● BF4RP / BF4GP Sensors Fiber Optic Sensors Door/Area Sensors (brown) +V (brown) +V Proximity (black) Control output Load Sensors (black) Control output Load (white) Self-diagnosis output 12-24VDC 12-24VDC (white) Self-diagnosis output Load Load Pressure...
  • Page 4 BF4 Series Installations Mounting amplifier unit [Mounting] [Removing] ① Hook the front part of the amplifier on DIN rail. Press the ② rear part of the amplifier on DIN rail. Push the back of amplifier toward ① and lift the hole for fiber toward ②...
  • Page 5 Fiber Optic Amplifier Mode Setting Change the mode setting switch to [SET] Photoelectric LOCK Sensors Fiber Sensitivity setting Set/Relase the interference prevention function Optic Sensors Light ON Dark ON Press [ON]+[OFF] at the same time for 2 sec. Door/Area Sensors The stability indicator [STAB] flashes continuously Press the [ON] Press the [OFF]...
  • Page 6 BF4 Series Setting as max. sensitivity (common) Prohibition of inputting External sensitivity setting [BF4 -R] ① Set the mode setting switch to [SET]. Even though mode switch is at Lock position, it is able to ② If there is no sensing target, input external sensitivity setting when Switch 1 and Switch - Light ON: Press the [ON →...
  • Page 7 Fiber Optic Amplifier Timer (OFF Delay) Function Stop Transmission Function Photoelectric -Operation Test [BF4R/BF4G/BF4RP/BF4GP/BF4 -R] [BF4 -E] Sensors This function is available under light ON state only and it is Standard type and External input sensitivity setting type Fiber for checking normal state of the sensor. both contain the built-in OFF Delay timer, approx.
  • Page 8 BF4 Series Self-Diagnosis Function (common) Mutual Interference Prevention Function (common) When fiber hood is contaminated by dust, transmitted light is lowered by element ability loss or received light is Two fiber optic cables can be mounted very closely by lowered by missing of optical axis, the self-diagnosis output setting different transmission frequencies.

This manual is also suitable for:

Bf4rpBf4gpBf4rBf4gBf4r-eBf4g-e ... Show all

Table of Contents