Page 1
All rights, including rights created by patent D-65205 Wiesbaden grant or registration of a utility model or design, are Tel.: +49 (0)611 97393-0 reserved. Heitronics GmbH reserves the right to make Fax: +49 (0)611 97393-26 modifications and improvements in their design without E-Mail: info@HEITRONICS.com prior notice.
Page 2
Please pay attention to the instruction given in MAINTENANCE AND CALIBRATION. HEITRONICS production meets the latest technical development thereby applying sophis- ticated components. Nevertheless, functional errors may occur in exceptional cases. The failure of an instrument may cause a measuring value being issued which seems to be correct, but is wrong.
Page 3
This declaration is valid for the following products: Geräteart: Infrarot Strahlungspyrometer Type of instrument: Infrared Radiation Pyrometer Typenbezeichnung: KT15 II Serie KT15 II Series Designation of model: Diese Erklärung wird abgegeben durch This declaration is issued by HEITRONICS Infrarot Messtechnik GmbH...
Page 4
PREFACE The remarkable features of the HEITRONICS devices are a design suitable for specific application as well as an uncom- plicated operation. Nevertheless, it is recommended to read the entire instruction manual before putting the instruments into operation. Please observe the safety instructions as well as the particu- larly emphasized annotations when reading the pertinent in- struction to the operation.
KT15.81 II / KT15.82 II ................3-18 KT15.83 II / KT15.85 II ................3-19 START-UP ......................4-1 Mounting ..................... 4-1 Fig. Mounting KT15 II Protective Cooling Jacket ........4-1 Electrical Connection .................. 4-2 Operation without serial interface ..............4-2 Operation with serial interface..............4-2 Optical Adjustment ..................
Page 6
Communication via interface ..............5-20 Preparing the device for operation with interface RS232C ....5-20 Using the interface ................5-20 Control of communication ..............5-20 Data transfer from KT15 II for evaluation purposes ......5-21 Commands ..................5-21 Delimiter.................... 5-21 Input buffer ..................5-21 Description of commands .........
Accessories ......................................................Code ........................... Further data ..................................................Hereby it is confirmed that the Infrared Radiation Thermometer specified above conforms to the data indicated in the specifications. Tester: Wiesbaden, DATA SHEET KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 03/01/15e...
For the application of the Infrared Radiation Thermometer under high ambient tem- perature, water-cooling, air purge fittings and vacuum tight lenses can be delivered as accessories. GENERAL KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 02/03/14e...
Page 9
KT15.85 II type is available. This device type oper- ates within the spectral ranges of 9.6 to 11.5 µm, where the transmission of the at- mosphere is extremely high. GENERAL KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 02/03/14e...
- acrylic, - cellulose, - fluorine compounds, - polycarbonate, - polyamide, - polyurethane, - polyvinylchloride and similar materials after analysis from 0 °C onwards. GENERAL KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 02/03/14e...
Page 11
KT15.64 II is provided for nitrogen oxide and KT15.69 II has been especially developed for determination of combustion tempera- tures. Using KT15.41 II, objects can be measured through gases and flames from 400 °C onwards. GENERAL KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 02/03/14e...
Operating voltages: AC: 12 (-10 %) ... 24 V (+ 10 %) 48 ... 400 Hz DC: 10.5 ... 30 V power consumption: ≤ 3.5 W Type of protection: IP65 TECHNICAL SPECIFICATIONS KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 21/03/12e...
Page 13
Ø 3 mm @ 1 m distance 60.0 °C laser Focus cross lines adapted to field of view < 1 mW 650 nm 60.0 °C laser with centering circle in the focus distance TECHNICAL SPECIFICATIONS KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 27/03/18e...
Page 14
Technical Information Cooling Jacket WK15 The HEITRONICS Infrared Radiation Thermometers can be operated at an environmental temperature of up to 60°C without any additional coolants. If the environmental tempera- tures are higher than that mentioned above, cooling fittings can be used.
2: Valid for Interface map with isolated digital input. 3: Valid for Interface map with open-collector output. 4: Valid for Interface map with 2 open-collector output. Further information next page 12-pin plug connector 12-pin socket-outlet TECHNICAL SPECIFICATIONS KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 28/06/18e...
Page 16
Assignment valid for RS232-Interface Only 1 variant possible (Version Data Sheet page 1-1) TECHNICAL SPECIFICATIONS KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 25/01/15e...
► for current output 0 to 20 mA ≤ 550 Ohm ► for current output 4 to 20 mA ≤ 550 Ohm For the signal evaluation, differential inputs are recommended. TECHNICAL SPECIFICATIONS KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 28/06/18e...
Page 19
0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 ** Value is > 20 °C. This setting is not recommended. Table: Temperature resolution Infrared Radiation Thermometer KT15.01 II / KT15.02 II TECHNICAL SPECIFICATIONS KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 26/01/16e...
6.15 0.10 0.45 1.10 3.70 10 s 0.10 0.30 0.75 2.45 ** Value is > 20 °C. This setting is not recommended. Table: Temperature resolution Infrared Radiation Thermometer KT15.21 II TECHNICAL SPECIFICATIONS KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 26/01/16e...
0.35 0.85 2.80 0.10 0.35 0.80 2.70 ** Value is > 20 °C. This setting is not recommended. Table: Temperature resolution Infrared Radiation Thermometer KT15.23 II / KT15.24 II 3-10 TECHNICAL SPECIFICATIONS KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 26/01/16e...
Page 22
0.15 0.50 1.20 3.95 10 s 0.10 0.35 0.80 2.65 ** Value is > 20 °C. This setting is not recommended. Table: Temperature resolution Infrared Radiation Thermometer KT15.25 II 3-11 TECHNICAL SPECIFICATIONS KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 26/01/16e...
0.05 0.10 0.40 0.05 0.05 0.15 0.40 ** Value is > 20 °C. This setting is not recommended. Table: Temperature resolution Infrared Radiation Thermometer KT15.41 II / KT15.42 II 3-12 TECHNICAL SPECIFICATIONS KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 26/01/16e...
Page 24
0.05 0.10 0.25 0.80 10 s 0.05 0.05 0.15 0.55 ** Value is > 20 °C. This setting is not recommended. Table: Temperature resolution Infrared Radiation Thermometer KT15.43 II 3-13 TECHNICAL SPECIFICATIONS KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 26/01/16e...
Page 25
300 ms 2,45 0,15 0,25 2,05 10 s 0,05 0,15 1,35 ** Value is > 20 °C. This setting is not recommended. Table: Temperature resolution Infrared Radiation Thermometer KT15.45 II 3-14 TECHNICAL SPECIFICATIONS KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 26/01/16e...
0.05 0.10 0.20 0.65 10 s 0.05 0.05 0.15 0.45 ** Value is > 20 °C. This setting is not recommended. Table: Temperature resolution Infrared Radiation Thermometer KT15.62 II 3-15 TECHNICAL SPECIFICATIONS KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 26/01/16e...
0.05 0.10 0.20 0.70 10 s 0.05 0.05 0.15 0.45 ** Value is > 20 °C. This setting is not recommended. Table: Temperature resolution Infrared Radiation Thermometer KT15.63 II 3-16 TECHNICAL SPECIFICATIONS KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 26/01/16e...
0.05 0.10 0.20 0.70 10 s 0.05 0.05 0.15 0.45 ** Value is > 20 °C. This setting is not recommended. Table: Temperature resolution Infrared Radiation Thermometer KT15.69 II 3-17 TECHNICAL SPECIFICATIONS KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 26/01/16e...
Page 29
0.05 0.10 0.30 0.05 0.05 0.05 0.20 ** Value is > 20 °C. This setting is not recommended. Table: Temperature resolution Infrared Radiation Thermometer KT15.81 II / KT15.82 II 3-18 TECHNICAL SPECIFICATIONS KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 26/01/16e...
Page 30
0.05 0.05 0.15 0.05 0.15 0.35 1.15 ** Value is > 20 °C. This setting is not recommended. Table: Temperature resolution Infrared Radiation Thermometer KT15.83 II / KT15.85 II 3-19 TECHNICAL SPECIFICATIONS KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 26/01/16e...
BSW 1/4" or spring flange. The device permits an easy adjustment of the Infrared Radiation Thermometer to the measured object. ( OPTIONS AND ACCESSORIES) ► mounting via adapter ( OPTIONS AND ACCESSORIES) START-UP KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 05/03/14e...
When operating without a serial interface the emissivity will be set as described in chapter 5.1. 4.4 Operation with serial interface Chapter 5.2.3 : Description of the commands ATTENTION: 12-pole connection required START-UP KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 05/03/14e...
ATTENTION Please observe the SAFETY INSTRUCTIONS. A pilot laser can be integrated into the Infrared Radiation Thermometer KT15 II in case a lens is used which is transparent to visible light. It marks the centre of the target di- ameter for the objective which has been mounted at works. It is not possible to show the minimum target diameter with this option.
Page 34
∗ Please, use only the marked connection for the respective combination! Recommended compressed air quality according to ISO 8573-1:2001; VDMA Specifications 15390 Solid contamination: Class 3-4 Humidity: Class 3-4 Oil content: Class 1-2 START-UP KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 07/09/18e...
OPERATION AND APPLICATION Configuration The Infrared Radiation Thermometers series KT15 II can be adapted to the process by means of parameterization. The adaptation is carried out via the keyboard or via the digi- tal interface. The operation via keyboard is described in the following. The communication via inter- face is carried out analog to it.
For the transmission of the measured temperature, a module which is recommended for the sensor is needed. OPTIONS AND ACCESSORIES. The figure shows the connection of a module with PT100 in three-wire technique to an Infrared Radiation Thermometer KT15 II. ATTENTION The device must be provided for 'Analog input'.
Page 37
If it is configured, the digital outputs can be reset via the digital input to the inactive state. 5.0.4 Use of the digital outputs DESCRIPTION OF COMMANDS: Command 2.14: Configuration of the digital outputs Example: 0 V will reset the digital output. KT15 II 95582944 OPERATION AND APPLICATION 05/03/12e HEITRONICS Infrarot Messtechnik GmbH...
≥ 70 °C. This switch is connected to the flange-plug ( chapter 3). Monitoring the analog output signal The type of the output signal can be selected for the series KT15 II Infrared Radiation Thermometers. For monitoring the output signal the '4 - 20 mA' type is recommended. At this setting a measuring temperature within the set temperature range will supply a signal between 4 and 20 mA.
By selecting 'MANUAL' or 'AUTO' mode, the self-reset of the memories is activated. The device detects a 'temperature gap' between two targets and resets maximum or minimum value memory at the end of the gap. OPERATION AND APPLICATION KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 08/07/16e...
Page 40
Via the extended configuration of the analog output, the maximum or mini- mum value memory can be switched to the analog output. → Commands 'Configuration of analog output' in Universal Protocol. OPERATION AND APPLICATION KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 08/07/16e...
Page 41
The reset time is retriggered automatically, when the value of the activated maximum value memory rises, resp. minimum value memory falls. This fea- ture can be selected for only one of the memory types. OPERATION AND APPLICATION KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 08/07/16e...
Press ESC several times to go back to main menu or to switch off the menu. The menu automatically switches off after two minutes. The Code is valid until you leave the menu (display off). KT15 II 95582944 OPERATION AND APPLICATION 05/03/12e HEITRONICS Infrarot Messtechnik GmbH...
KT15 pyrometer series .82A spectral range, detector type -50 temperature range beginning 1000 temperature range end Submenu Emi Enter .953 1.00 Enter Enter Change .953 1.00 Change Emi emissivity 5-10 KT15 II 95582944 OPERATION AND APPLICATION 05/03/12e HEITRONICS Infrarot Messtechnik GmbH...
Page 45
5-11 KT15 II 95582944 OPERATION AND APPLICATION 05/03/12e HEITRONICS Infrarot Messtechnik GmbH...
Page 46
5-12 KT15 II 95582944 OPERATION AND APPLICATION 05/03/12e HEITRONICS Infrarot Messtechnik GmbH...
Page 47
5-13 KT15 II 95582944 OPERATION AND APPLICATION 05/03/12e HEITRONICS Infrarot Messtechnik GmbH...
Page 48
5-14 KT15 II 95582944 OPERATION AND APPLICATION 05/03/12e HEITRONICS Infrarot Messtechnik GmbH...
Page 49
The following values will result: Minimum temperature Final temperature difference ≤ 150 °C 50 °C ≤ 200 °C 100 °C ≤ 1000 °C 200 °C > 1000 °C 400 °C 5-15 KT15 II 95582944 OPERATION AND APPLICATION 05/03/12e HEITRONICS Infrarot Messtechnik GmbH...
Pari even Enter even Change Uart digital output even BauR baudrate Data data bits even even Hand handshake Pari parity Hand Stop stopbits flasch Hand with hardware handshake 5-16 KT15 II 95582944 OPERATION AND APPLICATION 05/03/12e HEITRONICS Infrarot Messtechnik GmbH...
Page 51
5-17 KT15 II 95582944 OPERATION AND APPLICATION 05/03/12e HEITRONICS Infrarot Messtechnik GmbH...
Page 52
5-18 KT15 II 95582944 OPERATION AND APPLICATION 05/03/12e HEITRONICS Infrarot Messtechnik GmbH...
Page 53
5-19 KT15 II 95582944 OPERATION AND APPLICATION 05/03/12e HEITRONICS Infrarot Messtechnik GmbH...
Data transfer from evaluation to Infrared Radiation Thermometer KT15II The ready-to-receive state of the Infrared Radiation Thermometer KT15II is signalized via line RTS. The coding shown in the following table shall apply. 5-20 OPERATION AND APPLICATION KT15II 95582944 HEITRONICS Infrarot Messtechnik GmbH 15/03/14e...
When a longer command has been received, KT15II issues an error message. 5.2.3 Description of the commands The commands for programming the parameters are described in separate instructions: Universal Protocol Communication via Serial Interface for all digital HEITRONICS Infrared Radiation Thermometers 5-21 OPERATION AND APPLICATION KT15II 95582944 HEITRONICS Infrarot Messtechnik GmbH...
MAINTENANCE AND CALIBRATION General information The design of HEITRONICS Infrared Radiation Thermometers provides for a long period of service without the necessity of special maintenance. It is advisable to check the display accuracy approximately every three months. Measuring errors may arise, for instance, owing to pollution of the lens. For this reason, this component should first of all be cleaned.
Page 57
Spectral emissivity of Infrared Radiation Thermometers and transmission curves of various synthetic materials........8-4 Spectral emissivity ε, transmissivity ε and reflection ρ of glass ......8-5 Dimensions KT15 II ..................8-6 Target Diameter ....................8-8 Transmission curves (illustrated in a diagram): Spectral Response 2.0 …...
Page 58
Fig. 10a Spectral emissivity of various materials Fig. 10b Total emissivity of some materials at a temperature of 20 °C (spectral range 8 ... 14 µm) FIGURES KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 02/06/08e...
Page 59
Fig. 12 Emissivity of various foils FIGURES KT15 II 95582944 HEITRONICS Infrarot Messtechnik GmbH 02/06/08e...
Page 73
HEITRONICS is not responsible. Warranty does not include batteries. The device must be returned to HEITRONICS in the original packaging, carriage paid. Costs for taxes, fees and customs duties are to be paid by sender. Shipping damage is borne by the sender.
Page 74
For details about our regional representatives, please, refer to our website www.heitronics.com. Réseau des ventes Vous pouvez trouver les coordonnées de nos représentants régionaux sur notre site Web www.heitronics.eu. Organizacion de la venta Informaciónes referente a nuestros regionales colaboradores de venta se encuentran en nuestra pagina web www.heitronics.eu.
Need help?
Do you have a question about the KT15 II and is the answer not in the manual?