Download Print this page

HEIL 1 For All TSTAT0713 Installation Manual page 14

Programmable temperature & humidity

Advertisement

Sample Wiring Diagrams
Accessory Wiring - All Units
Installation of outdoor temperature
sensor, and humidification system.
W2
Y2
DEHUM
RS+5
RS1
RSGND
3 conductor, 18 gauge unshielded
cable from the thermostat to the
remote sensor.
RS-GND
RS
RS+V
Optional outdoor sensor
Pages 5, 8, 22, and 24 of Owner's Manual
W1/O/B
Y1
G
HUM
L
R
C
Optional wiring for
humidity system
HUMIDIFIER
Page 13