12
13
14
15
16
4.6.3 Use
2
Read E
PROM's specific area as unit of 128(80h)-byte. ( 84h )
4.6.4 EDID Write
EEPROM access by using DDC2B protocol
1-Byte write
START
A0
L : 0x00~0x7F
D : data
8-byte write
START
A0
L : 0x00,0x10,....0x70
4.6.5 EDID Read
DDC2B Command.(A0/A1)
START
A0
- 128 Byte transfer of EDID Buffer of MICOM
5.
Standard of Auto/Manual equipment adjustment
No
Item
.
1
Voltage(V)
Black
2
Color
Level
coordinates
(9300/6500K)
3
Color
DRIVE1
coordinates
(6500K)
Color
DRIVE2
coordinates
(9300K)
Copyright ©
LG Electronics. Inc. All rights reserved.
Only for training and service purposes
A
L
D
A
A
A
L
A
Data
A
START
A
00
A1
Adjustment & measurement
5V± 0.3V / 3.3V±0.25V,
1.2V± 0.07
Auto Adjustment
X
0.313±0.005
Y
0.329±0.005
X
0.283±0.005
Y
0.298±0.005
80
AC
0
80
AE
0
80
STOP
....
A
A
Data8
STOP
A
Data1
. . .
Operation
standard
mode
MSPG : 126
MSPG : 126
MSPG : 126
- 17 -
5-Page 80~FF Read
6-Page
0~7F Read
6-Page 80~FF Read
7-Page
0~7F Read
7-Page 80~FF Read
Data128
A
CS
A
Operation
Pattern
MODE 12
Pattern4
MODE 12
Pattern 0
MODE 12
Pattern1
LGE Internal Use Only
STOP
Measurement
Position
TP of
Each power
Center
of Screen
Center
of Screen

Hide quick links: