LG 24MP60 Series Service Manual page 11

Chassis lm68a
Hide thumbs Also See for 24MP60 Series:

Advertisement

Other model if need input EDID on the line, please refer below steps:
Confirm whether module selection is correct or not on the self-diagnostics OSD
with signal cable disconnected.
Connect HDMI Signal Cable to DVI-D wafer.
Write EDID DATA to
Check whether written EDID data is correct or not.
-
.- Analog part EDID data
Connect analog Signal Cable to D-sub wafer.
Write EDID DATA to
*
check the line EEPROM flag :EEPROM address:A6,FA data:0x1F
Check whether written EDID data is correct or not.
(refer to Product spec).
 After writing EDID, send Elapsed Time Clear command.
(Elapsed time should not be displayed, after EDID writing)
: Confirm periodically (in the first set of new lot, process change) whether module name and
 If Elapsed Time Clear command isn't executed, module name, aging time and TCO word appear
on the self-diagnostics OSD.(Module name and aging time should not appear after writing EDID)
 Make sure to do FACTORY RESET at the final process.
3.2.5.9. Shipping condition
3.2.5.10 V-Com Adjustment
Copyright ©
LG Electronics. Inc. All rights reserved.
Only for training and service purposes
EEPROM(24C02)
EEPROM(24C16)
If NG ,pls press every key ,then check again.
aging time disappeared on the self-diagnostics OSD with signal cable disconnected.
Contrast
: 70
Power Switch
: Off
Brightness
: "100(Max)"
Color Select
: custom
Language Select
: Refer to product spec.
OSD Position: Match Position with Key position
Power indicator
: ON
Sound
: ON
Check HDMI Audio headphone function, after check, please set signal source to
RGB Mode by Hand.
DDC2B
by using
DDC2AB
by using
Key_full_check_IT
_SW_121122.ppt
- 11 -
protocol.
protocol.
LGE Internal Use Only