INSTRUCTIONS
1. Button description
1.1 Power button: To turn on and turn off the appliance.
1.2 Setting button: To set the corresponding setting.
2. Function description
2.1 Plug in: After the appliance is plugged in, one beep can be heard and the appliance enters the
standby condition, at that time, the "Power button" works while the "Setting button" is invalid.
2.2 Power on/Power off: Press the "Power button" once, the appliance will start working under the
default high setting, at the time, the corresponding indicator will light up.
2.3 A short beep can be heard after every valid press of the button.
2.4 Refill indicator: The refill indicator will illuminate in red when the water tank is lack of water. At
that time, you should refill the water tank with water. The appliance can only work normally after
refill the water tank and restart the appliance.
3. Preparation before power on
3.1 The working principle is that the ultrasonic wave atomizes water to produce visible cold mist
which is sprayed from the mist outlet.
3.2 The humidifier should be put at a flat and moisture-proof place which is above one meter from
the wall.
3.3 Open the top lid and fill the water tank with water to the "MAX" mark, align the gap with the
outlet (Fig. A),then close the top lid.
NOTE: Overflow will occur or no mist come out if the water level exceed the "MAX" mark.
3.4 Connect the appliance with power source.
3.5 Start the humidifier according to the instruction of control panel.

CLEANING AND MAINTENANCE

1. Daily maintenance
1.1 Make sure the humidifier is powered off and unplugged.
1.2 Take the water tank to the side of the faucet, empty the residual water and rinse the water tank,
then wipe and clean the base with cleaning cloth or towel.
1.3 Refill the water tank with clean water and replace it well in position.
2. Weekly maintenance
2.1 Repeat the operation of "Daily maintenance".
2.2 Add a small cup (about 200ml) of undiluted white vinegar or cleaning solution recommended
by manufacturer into the water tank. After 20 minutes, clean the water tank and the dirt near the
atomizer with a cleaning cloth.
2.3 Before sterilizing, remove the cleaning solution with warm water with a temperature less than
70°C and re-sterilize it with water.
3. Sterilization of the base and water tank
3.1 Fill the water tank with 1/2 of fresh water and add 1/2 tablespoon of chlorine bleach.
3.2 Make the solution stay in the water tank for 20 minutes and rinse it for a few minutes to ensure
that each inner surface can be washed.
3.3 After 20 minutes, empty the water tank and wash it with lukewarm water until no disinfectant
smells. Wipe the tank with a cloth or paper.
3.4 Refill the water tank and replace it well in position.
3.5 Clean the base and empty the excess water, remove deposits and dirt completely , and wipe it