Panasonic PE Series Instruction Manual page 2

Led bar display sensors

Advertisement

5
I/O CIRCUIT DIAGRAMS
Color code
<NPN output type>
D
(Brown) +V
(Black) Output
T
r
Z
D
(Blue) 0V
(Pink) Control input
Internal circuit
Users' circuit
Symbols ... D
: Reverse supply polarity protection diode
Z
: Surge absorption zener diode
D
T
: NPN output transistor
r
Color code
<PNP output type>
D
(Brown) +V
T
r
Z
D
(Black) Output
(Blue) 0V
(Pink) Control input
Internal circuit
Users' circuit
Symbols ... D
: Reverse supply polarity protection diode
Z
: Surge absorption zener diode
D
T
: PNP output transistor
r
*1: Output operation selection by control input
Connect to +V or open
Hysteresis (5% F.S. approx.)
ON
OFF
0
Set pressure
Low vacuum
High vacuum
(Vacuum pressure)
(Vacuum pressure)
Low pressure
High pressure
(Positive pressure)
(Positive pressure)
6
ERROR DISPLAY
If the display is as shown in the right figure, excess current
is flowing due to a load short-circuit. In this case, switch off
the power supply and check the load and output.
Note: The right figure shows the vacuum pressure type sensor. In case of the
positive pressure type sensor, the position of the indicators (red) is symmet-
rically opposite.
7
FUNCTIONAL DESCRIPTION
Set pressure pointer
Main scale
Power indicator (Red)
Operation indicator (Red)
Note: In case of the vacuum pressure type, the position of the indicators (red) is symmetrically opposite.
Designation
Set pressure pointer
Rotating the set pressure adjuster turns the pointer simultaneously.
(Note)
The value indicated by the pointer represents the set pressure level.
Sets the threshold level.
Vacuum pressure type
Rotating it counterclockwise, sets a higher vacuum level.
Set pressure adjuster
Positive pressure type
Rotating it clockwise, sets a higher positive pressure level.
'Pa' unit scale. It completely coincide with the LED bar display.
Main scale
PE-20 , PE-21 : kPa
PE-22 : MPa
It is an additional scale. It does not completely coincide with the
LED bar display. Use it as a reference.
Pressure unit is,
Sub scale
PE-20: cmHg, PE-21, PE-22: kgf/cm
PE- N: psi, PE- E: bar
Power indicator (Red)
Lights up when the power is ON.
Operation indicator (Red) Lights up when the output is ON.
Pressure indicator (Red) Shows the measured pressure level.
By using the
dicator, the resolution can be increased to twice than that in case
of using the pressure indicator only.
(EX.)
1 2
step indicator (Green)
Note: It is possible that the position of the set pressure pointer and the position of the pressure indi-
cator lighting up may not match. Use the set pressure pointer as a reference.
Load
+
12 to 24V DC 10%
-
100mA max.
*1
100mA max.
+
12 to 24V DC 10%
-
Load
*1
Connect to 0V
Hysteresis (5% F.S. approx.)
ON
OFF
0
Set pressure
Low vacuum
High vacuum
(Vacuum pressure)
(Vacuum pressure)
Low pressure
High pressure
(Positive pressure)
(Positive pressure)
Set pressure adjuster
Sub scale
.4
.6
40
60
.2
.8
20
80
100
kPa
1.0
PE-21
kgf/cm
2
Pressure indicator (Red)
OUT
1/2 STEP
1 2
step indicator (Green)
Description
2
1
step indicator in combination with the pressure in-
2
.6
.6
60
60
.8
.8
80
80
= 80kPa
= 82.5kPa
100
100
1.0
1.0
kgf/cm
kgf/cm
2
2
Turns off
Lights up
1/2 STEP
1/2 STEP
8
CONVERSION TABLE FOR PRESSURE UNITS
Pa
cmHg
1Pa
1
7.500617 10
1cmHg
1333.224
1
2
1kgf/cm
98066.5
73.55592
5
1bar
10
75.00617
1psi
6895
5.1715
2
(pound/inch
)
9
DIMENSIONS (Unit: mm)
PE-
(Asian)
Pressure indicator (Red) (Note)
Set pressure adjuster
Set pressure pointer
Power indicator (Red)
(Note)
5.5
Operation indicator
(Red)
Note: The figure illustrates the indicator position for the positive pressure type sensor.
For the vacuum pressure type sensor, the indicator position is symmetrically opposite.
PE- N (North American)
Pressure indicator (Red) (Note)
Set pressure adjuster
Set pressure pointer
Power indicator (Red)
(Note)
5.5
Operation indicator
(Red)
Note: The figure illustrates the indicator position for the positive pressure type sensor.
For the vacuum pressure type sensor, the indicator position is symmetrically opposite.
PE- E (European)
Pressure indicator (Red) (Note)
Set pressure adjuster
Set pressure pointer
Power indicator (Red)
(Note)
5.5
Operation indicator
(Red)
Note: The figure illustrates the indicator position for the positive pressure type sensor.
For the vacuum pressure type sensor, the indicator position is symmetrically opposite.
10
INTENDED PRODUCTS FOR CE MARKING
The models listed under '
CE Marking.
As for all other models, please contact our office.
Contact for CE
<Until June 30 ,2013>
Panasonic Electric Works Europe AG
Rudolf-Diesel-Ring 2, D-83607 Holzkirchen, Germany
<From July 1 ,2013>
Panasonic Marketing Europe GmbH Panasonic Testing Center
Winsbergring 15, 22525 Hamburg,Germany
http://panasonic.net/id/pidsx/global
Overseas Sales Division (Head Office)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
About our sale network, please visit our website.
PRINTED IN JAPAN
2
kgf/cm
bar
-4
-5
-5
1.019716 10
10
-2
-2
1.3595099 10
1.333224 10
1
0.980665
1.019716
1
0.07039
0.06895
2-M3 female threads,
6 deep
13
M5 female thread, 6 deep
Pressure port R
3.7 cable, 0.5m long
2-M3 female threads,
6 deep
54
30
12
13
10-32UNF female thread,
6.4 deep
Pressure port NPT
3.7 cable, 0.5m long
2-M3 female threads,
6 deep
54
30
14
13
M5 female thread, 6 deep
Pressure port
3.7 cable, 0.5m long
SPECIFICATIONS' come with
1
© Panasonic Industrial Devices SUNX Co., Ltd. 2013
psi
2
(pound/inch
)
-4
1.45 10
0.1933
14.217
14.503
1
1 4
male thread
25
14
25
1 4
male thread
25
14
25
1
male thread
8

Advertisement

loading

This manual is also suitable for:

Pe-20Pe-20nPe-20ePe-21Pe-21nPe-21e ... Show all