Vaillant ecoTEC exclusive 627 Installation And Maintenance Instructions Manual page 48

Hide thumbs Also See for ecoTEC exclusive 627:
Table of Contents

Advertisement

Code
Parameter
D.035
3-way valve position
D.036
DHW flow rate
D.039
Solar inlet temp. actual
value
D.040
Flow temperature actual
value
D.041
Return temperature actual
value
D.044
Ionisation value actual
value
D.046
Pump mode
D.047
Current outside temperat-
ure
D.050
Offset min. speed
D.051
Offset max. speed
D.052
Min. gas valve steps offset
D.058
Solar post-heating
D.060
Number of safety therm.
shut-downs
D.061
No. of shut-downs in ign.
flame controller
D.064
Avg. ignition time
D.065
Max. ignition time
D.067
Remaining anti-cycl. time
for heating
D.068
Number of first start at-
tempts
D.069
Number of second start
attempts
D.070
3-way valve operation
D.071
Max. heating target flow
temp.
D.072
Pump overrun after cylin-
der charging
D.073
Offset setting for comfort
mode
D.074
Anti-legionella funct. with
integrated cyl.
D.075
Max. cylinder charging
time
48
Values
Unit
Min.
Max.
Current value
Current value
l/min
Current value
°C
Current value
°C
Current value
°C
Current value
0
1
Current value
°C
0
3000
rpm
-990
0
rpm
0
99
0
3
Current value
Current value
Current value
s
Current value
s
Current value
min
Current value
Current value
0
2
40
80
°C
0
10
min
−15
5
K
0
1
20
90
min
Installation and maintenance instructions ecoTEC exclusive 0020193966_04
Increment, select, explanation
Position of the prioritising diverter
valve
0. Heating mode
1: Parallel operation (mid-position)
2: DHW mode
> 800 = No flame
< 400 = Good flame
0 = Relay with disable facility
1 = PWM with disable facility
(with Vaillant weather-compensated
control)
Nominal value set in factory
Nominal value set in factory
The offset is specified at the gas
valve assembly.
1
Only products with integrated do-
mestic hot water generation
0 = Solar post-heating deactivated
3 = Domestic hot water activated
(min. target value 60 °C)
Number of safety cut-out switch-off
sequences
Unsuccessful ignitions at 1st at-
tempt
Unsuccessful ignitions at 2nd at-
tempt
0 = Normal operating mode
1 = Mid-position (parallel operation)
2 = Permanent heating position
Target value maximum heating flow
temperature
1
Internal pump
1
Only products with integrated do-
mestic hot water generation
1
0: Off
1: On
Max. charging time for domestic
hot water cylinder without inde-
pendent control system
1
Factory
Own
setting
setting
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
0
Not ad-
justable
0
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
0
75
2
0
1
45