B Installer Level - Overview - Vaillant ecoTEC exclusive 627 Installation And Maintenance Instructions Manual

Hide thumbs Also See for ecoTEC exclusive 627:
Table of Contents

Advertisement

#
Maintenance work
33
Checking the CO/CO₂ content following maintenance work
34
Checking leak-tightness
Installer level – Overview
B
Setting level
Installer level →
Enter code
Installer level → Fault list →
F.XX – F.XX¹
Installer level → Test programs → Check programs →
P.00 Purging
P.01 Maximum load
P.02 Minimum load
P.04 Reset eGas CH
P.06 Filling mode
Installer level → Test programs → Function menu →
T.01 Internal pump
T.02 3-way valve
T.03 Fan
T.04 Cylinder charging pump
T.05 Circulation pump
T.06 External pump
T.08 Burner
Installer level → Test programs → Electronics self-test →
Self-test
Installer level → Appliance config. →
Language
Target flow temp.
DHW temperature
Green iQ
Auxiliary relay
¹Fault lists are only displayed, and can only be deleted, if faults have occurred.
0020193966_04 ecoTEC exclusive Installation and maintenance instructions
Values
Unit
Min.
Max.
00
99
Current value
30
75
30
60
1
10
Interval
Annually
Annually
Increment, select, explanation
1 (competent person code 17)
Yes, No
Yes, No
Yes, No
Yes, No
Yes, No
On, Off
On, Off
On, Off
On, Off
On, Off
On, Off
On, Off
Yes, No
Languages available for selection
1
1
Product with hot water generation or connected
domestic hot water cylinder
On, Off
1 = Circulation pump
2 = External pump
3 = Cylinder charging pump
4 = Extractor hood
5 = External solenoid valve
6 = External fault message
7 = Solar pump (not active)
8 = eBUS remote control (not active)
9 = Legionella protection pump (not active)
10 = Solar valve (not active)
Default
setting
Country-
specific
On
2
43