8. Attach the cover/light fitter(5)(6) to the switch
assembly housing(1) using the two
screws(2) that were removed in Step 2)
(Figure 4.)
!
WARNING
To avoid fire or electrical shock, be
careful not to pinch wires between the
switch housing assembly and the cover.
9. Proceed to "Installation of Glass Bowl"
section.
Installation of Glass Bowl
1. Install two 50-watt (maximum) mini-
candelabra base halogen bulbs (included)
into the fitter sockets.
!
WARNING
To avoid fire hazard, do not exceed
wattage indicated on the fixture.
!
WARNING
Over lamping the light kit will result in
the lamps being automatically shut off.
Use only 50-watt maximum mini-
candelabra base halogen lamps. Turn off
electricity before replacing the lamps.
2. Place the glass bowl(1) onto the light fitter
by inserting the threaded nipple through the
bottom hole of the bowl.
3. Where applicable, insert the fan speed
control switch chain through the offset hole
in the bowl cap, glass bowl and then the
offset hole in the outer bowl cap.
For repair parts, phone:
Trouble Shooting
TROUBLE
PROBABLE CAUSE
1. Both Lamps Will
1. Wiring not complete.
Not Illuminate.
2. Light bulbs do not light.
2. The 1.25A fuse may have blown.
Air Comfort Products
DIVISION OF EMERSON ELECTRIC CO.
8100 W. Florissant • St. Louis, MO 63136
4. Install the light switch chain through the
center of the finial nut(3). Screw the finial nut
finger tight onto the fitters threaded nipple.
CAUTION
Be sure that the fan switch chain does not
make contact with the light bulbs. If
necessary reposition the light fitter to avoid
the fan switch chain from touching the light
bulbs.
5. Install pendants(2) onto light fixture chain
and fan switch chain.
NOTE: It is advisable to periodically check
the tightness of the finial.
6. Installation is complete. Turn on electricity at
main fuse or circuit breaker box.
FAN SWITCH
CHAIN
FITTER
50-WATT
SOCKET (2)
MINI-CANDELABRA
BASE HALOGEN
BULBS (2)
BOWL CAP
LIGHT FITTER
THREADED
NIPPLE
(1) GLASS
BOWL
OUTER BOWL CAP
(3) FINIAL
FAN SPEED CONTROL
LIGHT SWITCH
SWTICH CHAIN
CHAIN
(WHERE APPLICABLE)
PENDANTS (2)
Figure 6
1-800-654-3545
SUGGESTED REMEDY
1. Check all wiring connections to light kit.
2. Check and replace light bulbs.
3. Replace fuse.
Form No. BP7414
Part No. F40BP74140000
Printed in China 03/10
READ AND SAVE THESE INSTRUCTIONS
Model Number:
LK130
Suitable for Damp
Locations
Includes 3 finials and 3 outer bowl caps in the following finishes:
Oil Rubbed Bronze, Brushed Steel & Appliance White
Includes: Two 50-Watt Mini-Candelabra Base Halogen Bulbs
Net Weight:
Ceiling Fan Light Fixture Owner's Manual
LIMITED WARRANTY
What The Warranty Covers:
All products covered by this Owner's Manual are warranted against all defects in workmanship and materials. You must be the original purchaser or
user of the product to be covered.
What The Period Of Coverage Is:
All components are covered by this warranty for one year from the date you purchased your light fixture. ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED
TO ONE YEAR.
What Will Emerson Electric Co. Do To Correct Problems:
Emerson Electric Co. will replace a defective Emerson Light Fixture at no charge to you. WE WILL SHIP THE REPAIRED PRODUCT OR
REPLACEMENT TO YOU AT NO CHARGE, BUT YOU ARE RESPONSIBLE FOR ALL COSTS OF REMOVAL, REINSTALLATION AND SHIPPING OF THE
PRODUCT TO EMERSON ELECTRIC CO.
How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE LIGHT FIXTURE TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR
OTHER PROOF OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division of
Emerson Electric Co., 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product with your request.
• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center.
You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Light
Fixture should be properly packed to avoid damage in transit since we will not be responsible for any such damage.
What Is Not Covered:
This warranty also does not cover any defects, malfunctions or failures caused by:
• Repairs by persons not authorized by Emerson Electric Co.,
• Use of parts or accessories not authorized by Emerson Electric Co.,
• Mishandling, improper installation, modifications or damage to your light fixture while in your possession, or
• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.
Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:
• The original purchaser or user ceases to own the product, or
• The ceiling fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no
employee, agent, dealer or other person is authorized to give any warranties on behalf of Emerson Electric Co.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT
RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not
limited to such damages as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing
other property which was damaged if this product does not work properly.
How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to
you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Form No. F40BP74140000
1.8
U L
Lbs.
®
Part No. BP7414
U.L. Model No.: LK130

Advertisement

loading

Summary of Contents for Emerson LK130

  • Page 1 PENDANTS (2) What Will Emerson Electric Co. Do To Correct Problems: Emerson Electric Co. will replace a defective Emerson Light Fixture at no charge to you. WE WILL SHIP THE REPAIRED PRODUCT OR 3. Where applicable, insert the fan speed...
  • Page 2 (7) BOWL CAP Figure 4 be performed by a licensed electrician. BOWL CAP WARNING: To reduce the risk of possible fire and electrical shock, install only on Emerson Model 3. Remove the center screw(4) from the OUTER BOWL CF130. FAN SWITCH CHAIN cover(5).