Page 1
Fundor T English Translation of the original instructions...
Page 2
This symbol indicates very important information. Failure to comply with it may result in personal injury. This symbol warns against hot parts. BEGO Bremer Goldschlägerei Wilh. Herbst GmbH & Co • Wilhelm Herbst-Straße 1 • D-28359 Bremen Telefon +49 421 2028-0 • Telefax +49 421 2028-100 • www.bego.com...
Fundor T Contents Page Instruction manual Safety instructions --------------------------------------------------------------------------- 4 About the unit Unit description ------------------------------------------------------- 6 Scope of delivery, Wearing parts and Extras --------------------- 6 Technical data --------------------------------------------------------- 6 Operation Installation ------------------------------------------------------------- 7 Working ---------------------------------------------------------------- 8 Care ------------------------------------------------------------------- 10...
Fundor T Safety instructions The Fundor T centrifugal casting machine is l Handling the machine designed exclusively for casting dental alloys, Prior to connection to the power supply check with the exception of titanium. Any other use is whether the specifications on the rating plate considered to be improper.
Page 5
Only a trained worker is allowed to install the Fundor T. Fundor T has go to be placed horizontally on a level working bench. l When laying cables and hoses, ensure that they are protected from hot components (e.g., moulds).
Fundor T Unit description The Fundor T is a benchtop machine for casting dental Centrifuging is started by closing the lid. The double- work. It can be used for precious metal, cobalt-crome jointed arm optimises the centrifugal force. The and metal-to-ceramik alloys or no precious metal starting speed is infinitely variable.
Fundor T Working Danger of burns due to hot parts! l Wear protective clothing (protective apron), safety shoes, safety goggles and protective gloves. l Always use mould tongs to move moulds and hot crucibles. l Place hot parts only on a fireproof surface.
Page 9
Fundor T Fig. 4 Key of figure 4 Main switch Fastening screws for automatic gas lighter Lamp „Operation“ Double-jointed arm Lamp „Prepare“ Counterweight 10 Crucible holder Switch for starting speed 11 Mould holder Fuse 4 Amp. 12 Adjusting lever for mould height...
Fundor T Working Important! We recommend to use the following base socket moulds for metal mould rings only: Base socket mould for metal mould ring - size 3 ..............Order no. 52 627 Base socket mould for metal mould ring - size 6 ..............Order no. 52 628 Base socket mould for metal mould ring - size 9 ..............
Fundor T Troubleshooting Fault Reason Remedy The lid cannot be opened no current Connect the machine to the network, switch on and wait 15 sec. Without current: Open the lock with a thin bar or a screw driver (see fig. 3).
Need help?
Do you have a question about the Fundor T and is the answer not in the manual?
Questions and answers