C6.1
C6.2
Electrical installation and Operation Manual
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C6.1 and is the answer not in the manual?

Questions and answers

Geir Sørlie
July 7, 2025

Hei. Opplever at det blir altfor varmt i leiligheten. Termostatene er innstilt på 22,5 grader men på varme dager er innetemperaturen 26-27 grader. Hvilken innstilling kan jeg endre?

Summary of Contents for Komfovent C6.1

  • Page 1 C6.1 C6.2 Electrical installation and Operation Manual...
  • Page 2: Table Of Contents

    2.5.8. Control panel alarm message sound signal enable / disable..................21 2.6. Troubleshooting......................................21 APENDIX NO.1. KOMFOVENT CONTROL Terms of Use and Privacy Notice ................24 This symbol indicates that this product is not to be disposed of with your household waste, according to the WEEE Directive (2002/96/EC) and your national law.
  • Page 3: Electrical Installation Instructions

    ( ) White Green (B) (+) Red Control panel connection Yellow (A) ( ) White Yellow (A) ( ) White Green (B) (+) Red Green (B) (+) Red UAB KOMFOVENT we reserve the right to make changes without prior notice C6_20-08...
  • Page 4: Connection Of External Elements

    1. Ethernet connection of computer network or Internet 2. Controller panel connection 3. Connection of external elements Fig. 1.3 a. Controller with the connection terminals Fig. 1.3 b Connection diagram for external elements UAB KOMFOVENT we reserve the right to make changes without prior notice C6_20-08...
  • Page 5: Temperature Sensor Installation

    The sensor must be thermally insulated! Supply air temperature sensor B1 Water temperature sensor B5 Fig. 1.4 a Fig. 1.4 b >5D >5D Fig. 1.4 c * exeption R300V unit. UAB KOMFOVENT we reserve the right to make changes without prior notice C6_20-08...
  • Page 6: Operating Manual

    The air handling unit can be operated by one of the following panels (Fig. 2.1). C6.1 – panel with a touch screen for parameters of air handling unit setting and indication. The panel has integrated thermometer and hygrometer for indoor climate monitoring.
  • Page 7 IP and port number of the unit 80, according to the instructions of the network router. INTERNET Fig. 2.2 c Example of unit connection to a the Internet UAB KOMFOVENT we reserve the right to make changes without prior notice C6_20-08...
  • Page 8: Unit Control With A Smartphone

    After connecting the air handling unit to a computer network or the Internet, it can be controlled with your smart phone with an iOS or Android operating system. Download and instal “Komfovent Control” app. Connect by scaning QR code on the AHU door.
  • Page 9: Control Panel C6.1

    DCW duct coil (for water cooling) or DCF duct coil with outdoor DX unit (for DX cooling). ** For more about the ECO mode, read Section 2.4.4. UAB KOMFOVENT we reserve the right to make changes without prior notice C6_20-08...
  • Page 10: Review Of The Parameters

    Intensive. The recommended choice when there are more people inside the premises than usual. The ventilation intensity will be 70%. Boost. The recommended choice when it is necessary to quickly ventilate the premises. The ventilation will run at its maximum intensity. UAB KOMFOVENT we reserve the right to make changes without prior notice C6_20-08...
  • Page 11: Eco Mode

    If the temperature does not reach the required min./max. limits over a long period of time, the air volume can be reduced to the lowest possible value (20%). UAB KOMFOVENT we reserve the right to make changes without prior notice C6_20-08...
  • Page 12: Auto Mode

    Supply air temperature 21,9 °C Extract air temperature 22,1 °C Air temperature 16,6 °C Water temperature 25,3 °C Supply flow 350 m 1 / 3 UAB KOMFOVENT we reserve the right to make changes without prior notice C6_20-08...
  • Page 13: Scheduling

    Št • CUSTOM Schedule available for an individual user’s programming. The program is not set STAY AT HOME by default. UAB KOMFOVENT we reserve the right to make changes without prior notice C6_20-08...
  • Page 14 Program No. Days of the week Event start time Event end time Mode 07:00 08:00 AWAY 08:00 12:00 NORMAL Mo - Fr 12:00 17:00 INTENSIVE 17:00 18:00 AWAY UAB KOMFOVENT we reserve the right to make changes without prior notice C6_20-08...
  • Page 15: Air Quality

    Reset settings removed from the premises, the same temperature air will be supplied back. UAB KOMFOVENT we reserve the right to make changes without prior notice C6_20-08...
  • Page 16 B7 input. With special modes (KITCHEN, FIREPLACE, OVERRIDE and HOLIDAYS) the unit will always operate only in the CAV mode, regardless of the selected flow control. UAB KOMFOVENT we reserve the right to make changes without prior notice C6_20-08...
  • Page 17 Last test 2020-08-18 12:00 * Available only if optional fire damper controller is configured and connected. Refer to Fire damper controller manual for more information. UAB KOMFOVENT we reserve the right to make changes without prior notice C6_20-08...
  • Page 18 In case of entering the incorrect room humidity setting, there is the risk of incorrect operation of the protection against icing and of freezing of the counterflow heat exchanger. UAB KOMFOVENT we reserve the right to make changes without prior notice C6_20-08...
  • Page 19 Modbus Clean filters calibration. Resets dirty filter timer, after replacing air filters. Advanced settings Komfovent Control. Here it is possible to reset user password, used for log-in to Komfovent Control app, that controls AHU via smartphone. Connectivity Reset settings. Resets all the user settings and restores factory configuration.
  • Page 20: Control Panel C6.2

    2.5.6. Turning the unit on/off Pressing the OFF button turns off the air handling unit. To activate the unit, press the same on/off button, or choose one of the modes directly. UAB KOMFOVENT we reserve the right to make changes without prior notice C6_20-08...
  • Page 21: Keypad Lock

    To remove the fault, follow the instructions in the troubleshooting tables. • If nothing is shown on the control panel, check for damage to the cable that connects the remote panel to the unit. UAB KOMFOVENT we reserve the right to make changes without prior notice C6_20-08...
  • Page 22 Table 2.6.1. Alarms displayed in the C6.1 control panel, their possible causes and elimination methods Code Notification Possible cause Elimination Low supply air flow Too high resistance of the ventilation Check the air valves, air filters or ventilation system. system for clogging.
  • Page 23 However, if a fault is not eliminated, the device will either start again and then stop, or will not start and the error message will continue to be displayed. UAB KOMFOVENT we reserve the right to make changes without prior notice C6_20-08...
  • Page 24: Apendix No.1. Komfovent Control Terms Of Use And Privacy Notice

    Terms carefully and start using the KOMFOVENT CONTROL application only if the terms are clear and acceptable. KOMFOVENT reserves the right, at its sole discretion, to change these Terms of Use. If you continue to use KOMFOVENT CONTROL after we post changes to the Terms of Use, you are signifying your acceptance of the new terms.
  • Page 25 To improve the product and the KOMFOVENT CONTROL operation; • To handle complaints and warranty requests. The legal basis for the processing of such data is the execution of the agreement on the use of the KOMFOVENT CONTROL mobile application. 5.4. Storage and Deletion Data specified in point 5.1 Installation is periodically sent to the KOMFOVENT server.
  • Page 26 If you receive an error message or notice the error yourself, please report it to KOMFOVENT. KOMFOVENT shall not be held liable for any direct or indirect loss incurred by you or others if the KOMFOVENT CONTROL app cannot continue to operate as expected.
  • Page 27 UAB KOMFOVENT we reserve the right to make changes without prior notice C6_20-08...
  • Page 28 UAB KOMFOVENT PARTNERS TECHNINĖS PRIEŽIŪROS SKYRIUS / SERVICE AND SUPPORT J. PICHLER Gesellschaft m. b. H. www.pichlerluft.at Tel. +370 5 200 8000 service@komfovent.com Ventilair group www.ventilairgroup.com ООО «КОМФОВЕНТ» ACB Airconditioning www.acbairco.be Россия, Москва ул. Выборгская д. 16, REKUVENT s.r.o. www.rekuvent.cz стр.