INSTAllATION

MOUNT CONTROl

See figures 2 & 3 .
1 . Remove front cover by pulling straight out .
2. P osition the back plate on the wall and mark the locations for the wire access hole and the
mounting screws . NOTE: The mounting holes can also be used to secure the back plate to a
standard horizontally mounted junction box .
3. F or mounting on drywall, drill two 3/16" dia. mounting holes and a 3/4" opening for the wires.
4 . Insert the drywall anchors provided into the mounting holes flush with the wall surface .
5 . Run 4-wire cable from the humidifier to the control location .
6. S ecure back plate using the two #8 x 1-1/2" screws provided.
7. A fter connecting the wires, tuck excess wire into the wall and fill the opening with insulating
material . Failure to seal the opening may result in inaccurate operation due to drafts .
fIGURE 2 – Disassemble Control
RH SETTING
LABEL
4
61000790B AA Model 65 Humidifier Control Install.indd 4
T
A R
A P
L L
P U
C
R
H
H
FRONT COVER
BACK
PLATE
90-1667
10/12/11 9:47 AM