FireFlex Systems Inc. TotalPac 3 Owner's Operation And Maintenance Manual

Advanced integrated fire protection system, wet pipe system

Advertisement

Quick Links

Advanced Integrated Fire Protection System
®
T
P
3
OTAL
AC
Owner's Operation
and
Maintenance Manual
W
P
S
ET
IPE
YSTEM
FM-076A-0-19C

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TotalPac 3 and is the answer not in the manual?

Questions and answers

Summary of Contents for FireFlex Systems Inc. TotalPac 3

  • Page 1 Advanced Integrated Fire Protection System ® OTAL Owner's Operation Maintenance Manual YSTEM FM-076A-0-19C...
  • Page 2 ® OTAL Page ii Integrated Fire Protection System & M WNER PERATION AINTENANCE ANUAL Copyright © 2020 F Systems Inc. All Rights Reserved Reproduction or use, without express written permission from F Systems Inc, of any portion of this manual is prohibited. While all reasonable efforts have been taken in the preparation of this manual to assure its accuracy, F Systems Inc assumes no liability resulting from any errors or omissions in this manual, or from the use of the information contained herein.
  • Page 3: Table Of Contents

    ® OTAL Page iii Integrated Fire Protection System & M WNER PERATION AINTENANCE ANUAL Table of Contents Wet Pipe System General Section ......................Section 1- General description 2- Listings and approvals 3- Applicable standards 4- Environment 5- Features 6- Configuration description Mechanical Section ........................
  • Page 4 ® OTAL Page iv Integrated Fire Protection System & M WNER PERATION AINTENANCE ANUAL This page is intentionally left blank. FM-076A-0-19C...
  • Page 5: General Section

    ® OTAL Page 1 of 2 Integrated Fire Protection System General Section - Wet Pipe System 1- General description ® 2- Listings and approvals This T 3 integrated fire protection system by OTAL Systems Inc. consists of a wet pipe system trim In addition to being fabricated under tight ISO-9001 totally pre-assembled, pre-wired and factory tested.
  • Page 6: 5- Features

    ® OTAL Page 2 of 2 Integrated Fire Protection System General Section - Wet Pipe System 5- Features 6- Configuration description ® ® The T 3 unit is superior to many other products 3 wet pipe system is built around the Viking OTAL OTAL which are actually available on the fire protection market.
  • Page 7: Mechanical Section

    ® OTAL Page 1 of 8 Integrated Fire Protection System Mechanical Section - Wet Pipe System 1- Installation, operation & maintenance instructions 1.2 Preliminary inspection before placing the system in Note: Numbers indicated between brackets refer service figures 1 and 2 DETAILED SYSTEM TRIM SCHEMATICS. 1.
  • Page 8: Placing The System In Service

    ® OTAL Page 2 of 8 Integrated Fire Protection System Mechanical Section - Wet Pipe System 1.3 Placing the system in service 1.4 System Operation 1. Verify that the main water supply valve (D1) is CLOSED 1.4.1 In the SET condition and that the system is free of leaks.
  • Page 9: Emergency Instructions

    ® OTAL Page 3 of 8 Integrated Fire Protection System Mechanical Section - Wet Pipe System 1.6 Placing the system back in service after operation 1.5 Emergency instructions 1. Verify that the system has been properly drained. Verify To take system out of service that all automatic sprinklers are set and system piping auxiliary drain valves are CLOSED.
  • Page 10: Maintenance

    ® OTAL Page 4 of 8 Integrated Fire Protection System Mechanical Section - Wet Pipe System 1.7 Inspections and tests 1.8 Maintenance NOTICE : The owner is responsible for maintaining the fire NOTICE: The owner is responsible for maintaining the fire protection system and devices in proper operating protection system and devices in proper operating condition.
  • Page 11: Normal Condition

    ® OTAL Page 5 of 8 Integrated Fire Protection System Mechanical Section - Wet Pipe System 1.8.2 Quarterly 2- Wet pipe system 1. Check alarm pressure switch (C1) and optional water Note: Numbers indicated between brackets refer to figure 1 motor gong (C2) by opening the alarm test valve (B5).
  • Page 12 ® OTAL Page 6 of 8 Integrated Fire Protection System Mechanical Section - Wet Pipe System Figure 1 - Detailed system trim schematic for wet pipe system with excess pressure pump Typical wet pipe system with excess pressure pump (4" (100 mm) system shown) FIELD CONNECTION TO SPRINKLER PIPING NETWORK FIELD CONNECTION...
  • Page 13 ® OTAL Page 7 of 8 Integrated Fire Protection System Mechanical Section - Wet Pipe System Figure 2 - Detailed system trim schematic for wet pipe system with retard chamber Typical wet pipe system with retard chamber (4" (100 mm) system shown) FIELD CONNECTION TO SPRINKLER PIPING NETWORK FIELD CONNECTION...
  • Page 14 ® OTAL Page 8 of 8 Integrated Fire Protection System Mechanical Section - Wet Pipe System This page is left intentionally blank. FM-076A-0-59D...
  • Page 15: Trim Options

    ® OTAL Page 1 of 2 Integrated Fire Protection System Trim Options Wet pipe trim options 1. Fire department connection 2. Semi and full-flanged option ® The fire department connection option consists of a When required by the user, T 3 unit can be OTAL grooved tee fitting installed at the outlet of the alarm check...
  • Page 16 ® OTAL Page 2 of 2 Integrated Fire Protection System Trim Options This page is left intentionally blank. FM-076A-0-85B...
  • Page 17: Control Section

    ® OTAL Page 1 of 2 Integrated Fire Protection System Control Section 1. Remotely controlled unit without release control panel 1.1 Product description Figure 1 – Cabinet layout ® The T 3 wet pipe unit is provided without release OTAL control panel.
  • Page 18 ® OTAL Page 2 of 2 Integrated Fire Protection System Control Section Figure 2 - Junctions box layout for wet pipe system with excess pressure pump AC POWER POWER LIMITED CIRCUITS 120VAC, 50/60Hz or TBB Terminals 220/240VAC, 50/60Hz All conduits are installed by the Contractor through 1/2"...
  • Page 19: Electrical Section

    ® OTAL Page 1 of 2 Integrated Fire Protection System Electrical Section - Wet Pipe System 1. Remotely controlled configuration for wet pipe system with excess pressure pump ® This T 3 unit has been provided without an OTAL integrated control panel since all internal supervisory and releasing devices are to be connected and supervised from a remote releasing control panel.
  • Page 20 ® OTAL Page 2 of 2 Integrated Fire Protection System Electrical Section - Wet Pipe System 2. Remotely controlled configuration for wet pipe system with retard chamber ® This T 3 unit has been provided without an OTAL integrated control panel since all internal supervisory and releasing devices are to be connected and supervised from a remote releasing control panel.
  • Page 21: Dimensional Data & Cabinet

    ® OTAL Page 1 of 8 Integrated Fire Protection System Dimensional Data & Cabinet - Wet Pipe System ® 1- Cabinet for TotalPac 3 unit A field wiring electrical junctions box is integrated within the ® The TotalPac 3 unit cabinet is made of sturdy 14 gauge cabinet for connection of all electrical components in the trim steel.
  • Page 22 ® OTAL Page 2 of 8 Integrated Fire Protection System Dimensional Data & Cabinet - Wet Pipe System Figure 1 - Cabinet and inlets/outlets dimensions TBA, TBB & TBC TBA & TBC EXTENSION WITH EXCESS PRESSURE PUMP ØB OPTIONAL FIRE DEP'T CONNECTION OUTLET (DRILLED ONLY WHEN ORDERED)
  • Page 23 ® OTAL Page 3 of 8 Integrated Fire Protection System Dimensional Data & Cabinet - Wet Pipe System Figure 2 - Floor anchoring dimensions Table 3 - Floor anchoring dimensions Unit size 5" (127mm) 3" 37¾" 15" (959mm) (380mm) (80mm) TOP VIEW 4"...
  • Page 24 ® OTAL Page 4 of 8 Integrated Fire Protection System Dimensional Data & Cabinet - Wet Pipe System Figure 5 - Open drain details for single unit Table 5 - Manifold dimensions Unit OTAL Unit size Shown Without Front Doors 3"...
  • Page 25 ® OTAL Page 5 of 8 Integrated Fire Protection System Dimensional Data & Cabinet - Wet Pipe System ® 2- Skid mounted TotalPac 3 unit ® The TotalPac 3 unit skid base is made of sturdy 11 gauge ® IMPORTANT ! TotalPac 3 unit is NOT designed to be and 7 gauge steel.
  • Page 26 ® OTAL Page 6 of 8 Integrated Fire Protection System Dimensional Data & Cabinet - Wet Pipe System Figure 8 - Floor anchoring dimensions Table 8 - Floor anchoring dimensions 5" (127mm) Unit size 3" 37¾" 15" (959mm) (380mm) (80mm) TOP VIEW 4"...
  • Page 27 ® OTAL Page 7 of 8 Integrated Fire Protection System Dimensional Data & Cabinet - Wet Pipe System Figure 10 - Open drain details for single unit Unit Drain Pipe (dia. = C) Table 10 - Manifold dimensions Air Gap Unit size Water Supply Pipe 3"...
  • Page 28 ® OTAL Page 8 of 8 Integrated Fire Protection System Dimensional Data & Cabinet - Wet Pipe System This page is left intentionally blank. FM-076A-0-94B...
  • Page 29: Limited Warranty

    ® OTAL Page 1 of 2 Integrated Fire Protection System Limited Warranty Limited Warranty FireFlex Systems inc. (known herein "the In consideration of the warranty provisions contained Manufacturer") warrants to its customer that its products herein, the Customer hereby waives the benefit of any shall be free of defects in material [or part(s)] and statutory warranty or protection or remedy to which he may workmanship for a period of twelve (12) months from the...
  • Page 30 ® OTAL Page 2 of 2 Integrated Fire Protection System Limited Warranty User Notes FM-076A-0-96C...