Technician Setup Menu
Tech Setup Steps
This tech setting will select
Summer
the desired humidity level for
Away Mode
Summer Away Mode.
Humidity
Note: The thermostat will default
to the Dehumidify set point when
(Only displayed
this feature is enabled.
if summer away
mode is turned
"ON")
This feature uses both air
temperature and the relative
humidity to control the indoor
temperature based on how
Comfort
it actually feels for people to
Temperature
maximize comfort.
(Only displayed
if humidity is
turned "ON")
Enables a reminder for the user to
change the humidity pad.
Humidity
Pad
Reminder
Enables a reminder for the user to
change the UV light bulb.
UV Lamp
Reminder
Enables a reminder for the user
to change the IAQ Cell after
25,000 hrs.
IAQ Cell
Reminder
33
Setting the Humidity
Setting the Humidity
Comfort Temperature Index
Ambient
20%-25% 26%-35% 36%-45% 46%-55% 56%-65% 66%-75% 76%-85% 86%-90%
Temperature
50
50
50
51
50.6
50.7
52
51.2
51.5
53
52.3
52.5
54
52.9
53.3
55
53.5
54
56
54.1
54.6
57
54.7
55.2
58
55.8
56.3
59
56.4
56.9
60
57
57.5
61
58
58.5
62
58.9
59.4
63
60.1
60.6
64
61
61.6
65
62
62.5
66
62.7
63.3
67
63.4
64.1
68
64.6
65.4
69
65.3
66.2
70
66
67
71
67.2
68.2
72
68.3
69.3
73
69.7
70.7
74
70.8
71.9
75
72
73
76
72.9
73.9
77
73.8
74.7
78
75.2
76.3
79
76.1
77.1
80
77
78
81
77.9
79.1
82
78.7
80.2
83
80.3
81.8
84
81.1
82.9
85
82
84
86
82.8
85.1
87
83.7
86.1
88
85.3
87.9
89
86.2
88.9
90
87
90
35
LCD Will Show
Adjustment Options
Use the
and
to select the humidity level
for Summer Away Mode.
75
Humidity %
SUMMER AWAY
If ON is selected the ambient
temperature will operate
off of a combination of the
air temperature and the
relative humidity. When OFF
OF
the ambient temperatures
will operate off of the air
temperature only. The
thermostat will show the
comfort index in the ambient
temp area and drive the
heating and cooling based
on this.
COMFORT TEMP
Use the
or
OFF
select OFF, 600, 1000, 1500,
or 2000. These represent
hours of heat operation.
HUMIDITY PAD
Use the
or
key to
OFF
select OFF, 1 YR, 2 YR
UV LAMP
Use the
or
buttons to
OFF
select OFF, or 25 (stands for
25,000 hours).
IAQ CELL
50
50
50
50
50.7
50.9
51
51
51.5
51.7
52
52
52.5
52.8
53
53
53.3
53.6
54
54
54
54.5
55
55
54.7
55.3
56
56
55.4
56.2
56.9
56.9
56.6
57.3
58.1
58.1
57.3
58.2
59
59
58
59
60
60
59.1
60.1
60.9
60.9
60.1
61.1
61.9
61.9
61.4
62.4
63.1
63.1
62.4
63.4
64.1
64.1
63.5
64.5
65
65
64.3
65.3
65.9
65.9
65.1
66.1
66.8
66.8
66.4
67.4
68.2
68.2
67.2
68.2
69.1
69.1
68
69
70
70
69.1
70.1
71.1
71.4
70.3
71.3
72.3
72.8
71.7
72.7
73.7
74.2
72.9
73.9
74.9
75.6
74
75
76
77
74.9
76.1
77.1
78.6
75.7
77.2
78.2
80.2
77.3
78.8
79.8
81.8
78.1
79.9
80.9
83.4
79
81
82
85
80.3
82.3
83.6
86.6
81.7
83.7
85.1
88.1
83.3
85.3
86.9
89.9
84.7
86.7
88.4
91.4
86
88
90
93
87.3
89.5
92
95.8
88.6
91.1
94.1
98.5
90.4
92.9
96
100.5
91.7
94.5
98
103.2
93
96
100
106
WIFI Technician Setup Menu
Default
These steps/options are only used for trouble shooting, re-setting or
restoring to default the WIFI settings of the thermostat. They are not
buttons
needed for installation or initial setup.
1. Press the MENU button.
OFF
2. Press the WIFI button.
3. Configure the WIFI options as desired using the table below.
Use the + or - keys to change settings and the NEXT
or PREV key to move from one step to another.
Note: Only press the DONE key when you want to exit the WIFI Menu
WIFI Menu
OFF
SSID
Number
Firmware
key to
Version
OFF
WIFI
Provisioning
Reset
OFF
OFF
Setting the Humidty
Setting Target Humidity Setpoint
Follow the steps below to change your target humidity setpoint.
Press the HUMIDITY key
50
50
Use the
51
51.2
Press DONE when completed.
52
52.5
53
53.5
54
54.8
55
56
Note:
56
57
The target humidity setpoint is not programmable. Unlike
56.9
57.9
temperature, humidity does not change quickly and should not
58.1
59.1
be programmed.
59
60
60
61
Humidity is only energized during heat. Dehumidify is only
61.1
61.9
energized during cool. Heat and Cool each have their own target
62.1
62.9
setpoints.
63.4
64.1
64.4
65.1
65.5
66
66.5
66.9
67.6
67.8
68.9
69.2
70
70.1
71
71
72.4
72.6
Humidity Reading
73.8
74.3
75.2
75.8
76.6
77.4
78
79
79.6
80.6
81.2
82.7
82.8
84.3
84.4
86.2
Press key for
86
88
Humidity Reading
88.3
91
90.6
94.1
92.4
96
94.7
99
97
102
100.5
106.4
104
110.9
106.1
113.1
109.5
117.6
113
122
LCD Will Show
This step shows the SSID number
SSId
of the thermostat. (The network it
is connected to)
SSId HERE
This step shows the version of
firmware that is installed on the
thermostat.
This step allows you to reset the
thermostats WIFI connection
to change to a different WIFI
DELETE
network.
NETWORK
or
key to select the target humidity setpoint.
Adjustment Options
Default
Press NEXT to move to the
next step. Press DONE to exit.
N/A
Press NEXT to move to the
next step. Press DONE to exit.
N/A
Press and hold YES for three
seconds to reset.
N/A
34
36

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents