Labom LIMES LV1110-MO1 Series Operating Instructions

Labom LIMES LV1110-MO1 Series Operating Instructions

Limit switch

Advertisement

Quick Links

Limit switch LIMES
Type series LV1110-MO1
Operating Instructions
1 General Information....................................................................................................... 2
1.1 General Safety Notes .............................................................................................. 2
1.2 Intended Use ........................................................................................................... 2
1.3 Conformity with EU Regulations .............................................................................. 2
2 Transportation and Storage .......................................................................................... 2
3 Installation and Commissioning .................................................................................. 2
3.1 Mechanical Installation ............................................................................................ 2
3.2 Electrical Connection .............................................................................................. 3
3.3 Sensitivity adjustment and delay ............................................................................. 3
4 Operation ........................................................................................................................ 4
4.1 Maintenance / Service ............................................................................................. 4
5 Disassembly ................................................................................................................... 5
LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 27798 Hude Germany
Hotline: +49 4408 804-444 Fax: +49 4408 804-100 e-mail: sales@labom.com www.labom.com
BA_079_2019-05_10.00
Page 1/5

Advertisement

loading

Summary of Contents for Labom LIMES LV1110-MO1 Series

  • Page 1 3.3 Sensitivity adjustment and delay ................3 4 Operation ........................4 4.1 Maintenance / Service ..................... 4 5 Disassembly ........................5 LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 27798 Hude Germany BA_079_2019-05_10.00 Hotline: +49 4408 804-444 Fax: +49 4408 804-100 e-mail: sales@labom.com www.labom.com Page 1/5...
  • Page 2 In addition to this instruction, be sure to observe all statutory requirements, appli- cable standards, the additional technical specifications on the accompanying data sheet (see www.labom.com) as well as the specifications indicated on the type plate. General Safety Notes The installation, set up, service or disassembly of this device must only be done by trained, qualified personnel using suitable equipment and authorized to do so.
  • Page 3 Electrical Connection Complete the mechanical installation before you connect the device electrically. Set up all electrical connections while the voltage supply is switched off. Figure 1: electrical connection Connect power supply to terminals 1 (+) and 2 (-). The casing is electrically connected to terminal 2.
  • Page 4 3.3.1 Sensitivity adjustment switch on/off values in % configuration via PC and programming set MC1310 (option) Table 1: sensitivity adjustment for various media 3.3.2 Delay switch delay in sec Table 2: delay Operation During operation, take care that the device remains within its intended pressure and tem- perature ranges.
  • Page 5 Disassembly When measuring hot media, make sure that the device has cooled down prior to any dis- mounting or wear appropriate protective clothing to avoid burns. Switch off the power supply to the device before disconnecting the electrical connections. Once this is done, the device may be mechanically removed. Warning Opening pressurized lines might cause severe injuries.