ARP Control v5.x
ARP or SP0 Mode SetUp Button Function
Once in the ARP Control mode the SetUp button tests the control function and installation.
ARP BUTTON
START by holding the SetUp Button
until the first test is displayed.
Hold down the SetUp Button until
the next test is displayed.
Hold down the SetUp Button until
the next test is displayed.
WARNING: Hold down the SetUp Button to exit the
tests. There is no overheat protection when the tests
are being preformed.
Must see flashing dot on display for protection.
* USER NOTE: The v5.0 control is made for economy and therefore does not have an audible
alarm. For the v5.1, there is an audible alarm that informs the operator of conditions that
require operator intervention. During this test, the v5.1 tests the audible alarm, because this
test requires a person to hear the alarm, this is the only test of the audible alarm system. See
Troubleshooting Guide for further information.
Graphical User Instructions 04/20/2020 © ARPC L.L.C. All rights reserved.
ARP DISPLAY
FURTHER INFORMATION
IMPORTANT TEST
The first test checks the ARP
installation and thereafter tests
the controls ability to turn off the
fridge. When
OFF
is displayed,
go into the RV and check to
make sure the fridge turns off.
If
E10
displays
, the ARP or the
fridge is not wired correctly.
This test checks the fans and
wiring. When
FAn
is displayed
the fans should turn on. The
fans will turn off once test is
ended.
This test checks the controller
function and is automatic.
When
tSt
followed by
displayed the test is being
preformed (* See User Note).
When the test passes
displayed. If
F4
or
F5
displayed the test failed, contact
ARP and provide the error that
is displayed.
7
* *
*
is
PAS
is
are
Need help?
Do you have a question about the Fridge Defend and is the answer not in the manual?