Samsung SyncMaster 400DX-3 User Manual page 32

40" and 46" lcd professional display
Hide thumbs Also See for SyncMaster 400DX-3:
Table of Contents

Advertisement

1
Power control
2
Volume control
3
Input source control
4
Screen Mode control
5
Screen Size control
6
PIP on/off control
7
Auto adjustment control
8
Video wall Mode control
9
Safety Lock
- ID should show hexadecimal value of assigned ID, but ID 0 should be 0xFF.
- Every communication will be made in hexadecimals and Checksum is the sum of all
remainings. If it exceeds two digits,for example, it is 11+FF+01+01=112, discard the
number in the first digit like below.
example)PowerOn&ID=0
Header
command
0xAA
0x11
Header
command
0xAA
0x11
If you want to control every mechanism connected with Serial Cable regardless of its ID,
set ID part to "0xFE" and send commands. At the time, each product will follow commands
but it will not respond with ACK.
Power Control
Function
Personal Computer turns TV / Monitor power ON/OFF.
Get Power ON/OFF Status
Header
0xAA
Set Power ON/OFF
Header
command
0xAA
Power : Power code to be set on TV / Monitor
1 : Power ON
0 : Power OFF
Introduction
ID
ID
command
ID
0x11
ID
0x11
0x11
0~1
0x12
0~100
0x14
-
0x18
-
0x19
0~255
0x3C
0~1
0x3D
0
0x5C
0~1
0x5D
0~1
DATA
DATA 1
Length
1
Power
DATA
DATA 1
Length
1
1
DATA Length
0
DATA
DATA
Length
1
Power
CheckSum
12
CheckSum
CheckSum

Advertisement

Table of Contents
loading

Table of Contents