Summary of Contents for FARMSCAN Jackal

  • Page 1 For Serial Numbers 7000-9999 JULY 2020...
  • Page 2: Table Of Contents

    FLOW METER SETUP (WIZARD) ................27 SLIPPAGE METER (WIZARD)..................30 RATE MONITOR – LIQUID ..................31 RATE MONITOR – SOLID ..................32 BATCH METER (JACKAL CONTROL ONLY) ............... 34 BIN LEVEL SENSOR ....................36 AIR/VOLT/DEPTH/%/TEMP PRESSURE SENSOR ............. 37 TRIPS ........................40 ALARMS ........................
  • Page 3: General Description

    This version of the Jackal is completely unlocked, un-restricted and has the full feature set of the Jackal- Monitor. NB: Inputs consist of 7x Pulse & 2x Varying Inputs. Simply add additional sensors to utilise the Jackal to its full potential.
  • Page 4: Installation

    MOUNTING & INSTALLATION The Jackal Monitor & Spray Controller is provided with a suction window mount. An optional RAM style is also available for purchase at an additional cost. Farmscan Part No: AH-407-RAM Slide mount onto unit and push sideways to lock into place. Make sure you hear a click of the mount locking into place.
  • Page 5: Connections

    The supplied harness comes pre-terminated; however, this information is important if required in the future. 1. Connect power cable supplied DIRECTLY TO BATTERY 2. Ring terminals are used for battery connection and the bare end used to connect to the rear Jackal. (Refer above image for power connection) 3.
  • Page 6 REAR CONNECTIONS (MONITOR & CONTROL VERSION) The connector on the rear of the Jackal Monitor & Controller has the following points available for use when the supplied Tractor & Section/Implement harness is not used. BOTTOM ROW (GREEN PLUG) TOP ROW (GREY PLUG)
  • Page 7 B11 RS232 RX Notes as below: • The Jackal sprayer harness is wired to suit the Farmscan control valve bank (see below) • The Jackal Harness comes pre-terminated with Packard plugs & Pins o Adapter cables maybe purchased or included with some kits (Page7) •...
  • Page 8 TRACTOR HARNESS (CONTROL VERSION & SPRAY) Overview of Tractor Harness as below Connect to rear of Jackal P2 - GREY P1 - GREEN Jackal Tractor Harness Part # AC-4501/T Optional GPS Connection for Ground Speed 12v – To Battery Power...
  • Page 9 Connect to implement as required. Unused connectors and wires should be taped back to avoid weather corrosion or accidental shorting and damage. NB: All Red Wires are +12v (live when Jackal is on) – DO NOT SHORT AM-JACKAL-35 / JULY 2020...
  • Page 10 SPRAY HARNESS OVERVIEW (CONTROL VERSION & SPRAY) AM-JACKAL-35/ JULY 2020...
  • Page 11: Installing Sensors

    INSTALLING SENSORS The following examples will help to determine appropriate sensor input connections into the Jackal IF you choose to alter the pre-terminated cable to your specifications or have purchased the fully unlocked Jackal Control. TWO WIRE “REED” – BLACK END SENSOR (OLD SENSORS) KIT # 1007P, 2009, 2076 These kits will all include a “reed”...
  • Page 12 Use the generic wizard to setup the port and calibrate a sensor once installed. KIT #T-135 GPS units supplied from Farmscan are pre-programmed and ready to use with the Jackal Monitor. The diagram to the right shows which terminals to connect your GPS to.
  • Page 13 When using the Jackal as a batch meter with liquid, please ensure the appropriate flow meter is setup as per the previous instructions.
  • Page 14 There are 6 outputs available on the Jackal. (A8-A9 & B6-B9) This allows you to press the Run/Hold on the Jackal to enable an external operation. NB: This function is used in conjunction through an automotive relay.
  • Page 15: Overview

    The PAGE button is used to scroll through BATCH mode screens or Spray Control functions. 4. Select button (3 of) a. The Jackal has 3 buttons placed directly under the LCD. These buttons will change function in different menus.
  • Page 16 SCREEN LAYOUT The Jackal can display one, two or three lines of live information at any one time. Using the middle NAV/Enter button allows you to toggle between the different display modes when multiple inputs are being used. Example: 1 Line...
  • Page 17 (beep & on hold), language options, speed simulation for diagnostics. Outputs This menu is used to control the Jackal outputs. Refer to this manual and edit the outputs described ONLY to prevent damage to external sensors connected to the Jackal. GPS/Serial When an external GPS is connected view and ensure the GPS is setup correctly.
  • Page 18: Sprayer (Wizard) - Control Version & Spray

    SPRAYER (WIZARD) – CONTROL VERSION & SPRAY The Jackal can be setup to control an application rate when using both a speed & flow input. It offers Fully Manual, or Manual with auto dump valve open when stopped & Full Rate Control when varying speed.
  • Page 19 (speed-based). • STOP: Will simply put the Jackal on hold at a set speed. Press NEXT Change the input name if If you wish to setup a Tank...
  • Page 20 SETUP – MANUAL MODE (WIZARD) – NOT SO COMMON The Jackal can be setup to work in MANUAL mode in the event of no wheel speed or flow meter input, or combination of both. Manual mode simply allows adjustment of the flow control valve. In the event of a dump valve being installed, manual mode will close the dump valve &...
  • Page 21 Once the Sprayer Wizard has been run you are now ready to start spraying. Familiarise yourself with the Spray Controller layout as described below. The Jackal Spray Controller Menu is laid out in 4 easy to use menus. These can be easily accessed by pressing the PAGE button Default Section On/Off Control &...
  • Page 22 Quick Pre-set rates allows you to change Pre-Set Rates can be changed via When changing rates, the Jackal will rates on the go with ease. The Jackal will adjust the master control valve to allow SETUP > FRONT SCREEN > RATE control up or down to the desired rate more or less flow.
  • Page 23: Area & Speed Meter Setup (Wizard)

    AREA & SPEED METER SETUP (WIZARD) The Jackal can display Speed & Area in any combination of km/Ha or mph/acre. A pickup can be mounted either on a wheel hub or shaft. (Example image right) NB: THERE SHOULD BE A 5-10MM CLEARANCE BETWEEN SENSOR AND MAGNET WHEN 2 WIRE SENSORS ARE USED.
  • Page 24 Press NEXT buttons select and EDIT as required. Press NEXT Press NEXT to finalise the Wizard and return to the front screen THIS ENDS THE AUTO SET WIZARD SETUP FOR SPEED/AREA METER AM-JACKAL-35/ JULY 2020...
  • Page 25 Press NEXT Change the input name if you Press NEXT to finalise the desire, Press EDIT , Wizard and return to the Press NEXT front screen THIS ENDS THE MANUAL RATIO SET WIZARD SETUP FOR SPEED/AREA METER AM-JACKAL-35 / JULY 2020...
  • Page 26: Area & Speed Meter Using Gps Setup (Wizard)

    AREA & SPEED METER USING GPS SETUP (WIZARD) The Jackal can display Speed & Area in any combination of km/Ha or mph/acre. A wheel sensor is not required when using a GPS. GPS purchased from Farmscan are pre-programmed. If you BYO please ensure the following: •...
  • Page 27: Tachometer - Rpm Meter Setup (Wizard)

    TACHOMETER - RPM METER SETUP (WIZARD) The Jackal can display an rpm (Revolutions per minute) which is useful for monitoring fans or shafts. Available in slow & fast options. NB: THERE SHOULD BE A 5-10MM CLEARANCE BETWEEN SENSOR AND MAGNET OR 4MM BETWEEN PROX...
  • Page 28 Alarm Min/Max points if desire, Press EDIT , Wizard and return to the required. Using the NAV Press NEXT front screen buttons select and EDIT as required. Press NEXT THIS ENDS THE WIZARD SETUP FOR A TACHOMETER AM-JACKAL-35/ JULY 2020...
  • Page 29: Flow Meter Setup (Wizard)

    FLOW METER SETUP (WIZARD) The Jackal can be configured to monitor liquid products. If only one input is used the Jackal main screen will display the flow information of your choice. If the Jackal is also setup and installed with a Wheel Sensor input, the Jackal can be setup to display L/Ha for example.
  • Page 30 The Wizard is now complete. You will be returned to the Press EDIT Press NEXT Front Screen. or Press NEXT THIS ENDS THE AUTO SETUP WIZARD FOR FLOW METER REFER TO PAGE 30 TO SETUP AS RATE MONITOR L/Ha AM-JACKAL-35/ JULY 2020...
  • Page 31 THIS ENDS THE MANUAL CALIBRATION WIZARD SETUP FOR FLOW METER ** IT IS ADVISED TO CHECK YOUR MANUAL CALIBRATION BY MEASURING OUT A KNOWN QTY TO CONFIRM PPL** THIS CAN BE DONE BY COMPLETING THE CALIBRATION AUTO SET ON THE PREVIOUS PAGE (28) AM-JACKAL-35 / JULY 2020...
  • Page 32: Slippage Meter (Wizard)

    SLIPPAGE METER (WIZARD) The Jackal Monitor can allow the operator to compare two inputs and provide the result as a percentage. This is applicable when speed over ground is not necessarily equivalent to rotational speed of the wheel/s. This will enable you to set up a comparison between wheel speed and...
  • Page 33: Rate Monitor - Liquid

    RATE MONITOR – LIQUID The Jackal can be setup to display an application rate when using both a speed & flow input. Rates can be displayed in common formats such as L/Ha Sensors Required: • Wheel Sensor/GPS for Speed & Area calculation •...
  • Page 34: Rate Monitor - Solid

    Ensure there is product in the bin/tank to calibrate b) Have a bucket ready to catch the product c) Have a set of scales (e.g. Farmscan Part # 2199) ready to weigh the product From the front screen press Highlight WIZARD &...
  • Page 35 Press EDIT THIS ENDS THE SETUP FOR RATE METER SETUP AS kg/Ha Press EXIT 3 times to return to the front screen. Jackal will now display the flow rate as L/Ha with Area & Speed AM-JACKAL-35 / JULY 2020...
  • Page 36: Batch Meter (Jackal Control Only)

    1501 (Optional, from Farmscan) or any 12V Solenoid Valve Available Connections: Refer to Installing Sensors from PAGES 9-11 NB: The Jackal must be unlocked for controller for batch function to work. SETUP 1. Follow the setup guide on PAGE 27 for “Flow Meter Setup”...
  • Page 37 L/Min) – Change the FRONT SCREEN value from L/Min to L Refer to the Flow Meter Setup All Values can be reset or saved when using the TRIP functions THIS ENDS THE SETUP FOR A LIQUID BATCH METER AM-JACKAL-35 / JULY 2020...
  • Page 38: Bin Level Sensor

    BIN LEVEL SENSOR The Jackal can be configured with a bin level sensor for detecting empty/full. All Farmscan sensor will register as High/Low (H/L) for liquid or solid. Sensors Required: • Bin Level Sensor (A-2220P Sensor V1) • Bin Level Sensor (A-2221) o Capacitive Sensor V2 –...
  • Page 39: Air/Volt/Depth/%/Temp Pressure Sensor

    AIR/VOLT/DEPTH/%/TEMP PRESSURE SENSOR The Jackal can be configured to read & display a pressure sensor, voltage, percentage, temperature and display as: kPa, psi, bar, Volt, %, ˚C. Farmscan recommends sensors that can be powered by 12v but output from 0-5v in a linear style.
  • Page 40 Using the NAV or Press NEXT Press NEXT when done buttons select & EDIT as required. Press NEXT You will be returned to the front screen THIS ENDS THE MANUAL SETUP FOR A VARAIBLE VOLTAGE INPUT SENSOR (LIQUID) AM-JACKAL-35/ JULY 2020...
  • Page 41 CALIBRATION (LIVE READOUT) The Jackal also allows for a semi-automatic setup when the voltage values are unknown for a particular voltage input. A live voltage readout is displayed in the top left-hand side when the sensor is active. Follow the previous 5 steps, followed by:...
  • Page 42: Trips

    EDIT and name the Trip or DEL ALL (Delete All Trips) When you return to the TRIPS page the Trip will continue to accumulate. (Like above) You will need to SAVE/RESET the trip if you want to start from Zero (0) again AM-JACKAL-35/ JULY 2020...
  • Page 43: Alarms

    REFER TO OUTPUTS ON PAGE 44 IF YOU WANT TO CONNECT AN =ON: When the alarm is activated it will remain ON until EXTERNAL ALARM you enter the ALARM menu and manually reset =OFF: You can disable the alarm altogether AM-JACKAL-35 / JULY 2020...
  • Page 44: Inputs

    Full/Empty – On/Off – H/L • Input 6 & 7 (A6 & B2) – Varying Voltage o Volt: kPa/psi/bar/volt/%/˚C/ Once your inputs are setup and calibrated you now need to display them on the front screen AM-JACKAL-35/ JULY 2020...
  • Page 45: Generic Wizard

    GENERIC WIZARD The generic wizard allows to manually setup your Jackal in a customised method. You can also setup the Jackal to your requirements without using the wizard and navigating each menu by enabling and calibrating each port as required. Refer to the previous wizard guides to assist with manual setup.
  • Page 46: Other Settings

    Press the PAGE you to have alarms active EDIT stationary. button reveal the new while the Jackal is ON HOLD option. Adjust your speed to When the feature is enabled the test rate required. YES - return to the front...
  • Page 47: Outputs

    • Volt (Varying Voltage) 0-12v – Control Only For further explanation of setups of your OUTPUTS please contact our Farmscan Service Department. FLOW CONTROL VALVE WORKING BACK TO FRONT? When using the Jackal Spray Wizard outputs are automatically setup for your convenience.
  • Page 48: Gps/Serial

    The NMEA messages will change from N to Y ABOUT JACKAL Displays the Firmware version that’s installed on the Jackal. This screen also allows you to UNLOCK your Jackal to further functionality. Please contact Farmscan should you wish to purchase an unlock code. DIAGNOSTICS This screen provides the following information: •...
  • Page 49: Write Your Settings Down

    OUT 6 GROUND OUT 5 A8 OUT 2 OUT 4 A9 OUT 1 OUT 3 A10 +12v In B10 RS232 TX +12v Battery From GPS A11 -Ve In B11 RS232 RX Ground / GND Battery From GPS AM-JACKAL-35 / JULY 2020...
  • Page 50 NOTES __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ AM-JACKAL-35/ JULY 2020...
  • Page 52 Canning Vale WA 6155 AUSTRALIA SALES PH +61 (8) 6102 3200 SALES FAX +61 (8) 6102 3201 SUPPORT – Powered by AgriSync (Download the APP) TXT or Call: 0480 018 282 (WST) sales@farmscan.com.au www.farmscan.com.au ©2020 Farmscan Pty Ltd AM-JACKAL-35 JULY 10072020...