Page 1
Cross-Connect Cabinets 4220VB ™ and 4220VC with 3M Quick Connect ™ System (QCS) Blocks 2810 300- and 600-Pair Multi-use Cabinets for Pad Mount, Stake Mount, Wall Mount and Pole Mount (Walk-up Application Only) Instructions September 2015 78-0013-7947-4-A...
H/W/D Sided Profile covered in these instructions. QCS 2810 QCS 2810 (in) 3M QCS Frames can be ordered loaded with 44 7/8 x 4220VB QCS3 12 3/8 x blocks, partially loaded with blocks or empty. 10 1/8 The block tails can be terminated with 3M ™...
Page 4
September 2015 78-0013-7947-4-A Cross-Connect Cabinets 4220VC Series Cross-Connect Cabinets 4220VB Series ™ ™ with 3M Quick Connect System (QCS) 2810 with 3M Quick Connect System (QCS) 2810 ™ ™ Blocks Blocks...
Single Pair Test Probe 2827 and Dish ™ cabinet (if removed) 5. I nstall front plate of 3M Flex Port Kit 4297 ™ 3M Single Pair Test Probe 2827 (if installing) 6. Secure the cabinet to the pad Flex Port Kit 4297-4220SVB/VB-BP Kit ™ a. R einstall the four mounting lugs that Pan I.D. 4" x 9" (for 4220VB 300 pair)
Page 6
Secure anchor stakes to the sides of the cabinet with bolts provided l. Fill cabinet base with washed gravel to within 4" of top of skirt Top Pole Mount Bracket 4295 B,C,D ™ Pole-mount Hanger Brackets installed on the back ™ of a 3M Cross-Connect Cabinet 4220VB or 4220VC ™...
2. Wrap sealing tape around the cable to a diameter ¼" larger than cable port 3. Install back half of split gland into cabinet plate 4. Install front half of split gland around cable and bolt to cabinet plate 5. Bolt two halves of split gland together 8.0 Installing the 3M Quick Connect ™ System (QCS) 2810 frames 1. Rest the frame on the bottom frame support bracket 2. Align the frame pivot tabs with the slots...
September 2015 78-0013-7947-4-A 10.0 I dentification of 3M Quick 5. Secure frame to top frame support bracket ™ with 216C tool Connect System (QCS) 2810 Blocks Using Number Labels 10.1 Remove protector tape from identification pads on the blocks in the cabinet. 10.2 Select labels: blue for distribution or green for feeder. Detach a strip of 20 labels with your count from sheet. Carefully remove protective backing from strip. 10.3 Align the proper number, such as 1-11-21, etc., with the block pads on left and press into place.
Page 9
78-0013-7947-4-A September 2015 11.2 While holding the jumper wires in place, close 11.6 To remove jumper wires, open the cap and pull the cap and press to snap the latch firmly into wires straight out from block. place. 11.3 Route the jumper wires to distribution pair through wire loops on block ends and through vertical and horizontal wireways.
Page 10
Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture for a period of one (1) year from the time of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.