2178-S Splice Case will accommodate up to four 1.0" (25 mm) diameter cables inline when ™ ™ ™ using 3M 2522 trays. When using 3M 2523 or 3M 2524 trays it is limited to four .5" (12.5 mm) diameter cables inline. Butt applications will accommodate up to 1.0" (25 mm) diameter cables.
....... 6 ea c) plugs ..........2 ea d) cable ties, blue and green ....4 ea e) sheath scuff ........1 f) 3M ™ 2172 strength member clamps w/ rubber boot and hose clamp ..3 ea ™...
Page 6
....... 8 ea c) plugs ..........4 ea d) cable ties, blue and green ....4 ea e) sheath scuff ........1 f) 3M ™ 2172 strength member clamps w/ rubber boot and hose clamp ..4 ea ™...
Note: If wall mount bracket is required for the ™ 2178-LL Splice Case, use the 3M ™ 2199 Mounting Bracket Kit. Attach brackets to base (as shown) prior to cable preparation. ± Torque bolts to 25 in-lbs ± in-lbs (2.8 N 0.6 N...
1.75" (44.5 mm) b. Install strength members into 3M™ 2172 Strength Member Clamp by loosening screw and placing strength member under screw assembly. Insure strength member is flush with end of clamp prior to tightening the screw. Install rubber boot onto clamp.
Gasket cannot be used as a replacement for the original mastic sealant in a reentry. Inspect closure base and ensure the surface is clean and free from any debris. The gasket is factory installed in the 3M ™ 2178-L/S Series Fiber Optic Splice Case. For replacement of the gasket, place the gasket into the sealing channel with the gasket ports opening from the top.
Page 10
Use the 1.5" (38 mm) rubber tape included with the gasket to build the cable seals. Check the placement of the tape by positioning the strength member clamp where it will be anchored to the cable tie down bracket. Wrap the supplied rubber tape between sealing washers 2"...
Apply the grease to the gasket in the split or cut edge that allows for cable placement. grease Apply the supplied grease onto the cable area between the washers and to the outside of the wrapped sealing plugs, if any. Plugs should be placed inside gasket at the unused entry ports.
Page 12
Attach cables to closure base, using one of the two methods below: ™ 2172 Strength Member Clamp: Attach each cable to the closure base by installing a hose clamp through the slot on the strength member clamp, then around the cable tie down bracket, and tighten the clamp.
9.0 Splice Case Assembly ™ Note: If 3M 2183 Universal Aerial Hanger Bracket is to be used, follow its practice prior to splice case assembly. Before placing the closure cover on the closure base or the ™...
™ 11.3 If needed, two tray supports can be used. Tray supports may be ordered separately as the 3M 2178-STS ™...
Page 15
d. If placing one adapter on another adapter, make certain the note "AIR VALVE END" lines up for all adapters, gaskets, and the closure base. e. Set adapter, with the word "BOTTOM" facing down, on top of the closure. Note: It is important to orient the gaskets correctly on each level of the assembly (see Section 6.2 and 6.3).