Ratings; Input Rating; Output Rating; Other Specifications - Bergey POWERSYNC II Series Operator's Manual & Installation Instructions

Table of Contents

Advertisement

2. Ratings

2.1. Input Rating

Input Voltage Maximum (3 Phase Input)
Input Start Voltage Minimum
Input Operating Voltage Range
Input Frequency Maximum
Input Current Maximum
AC Backfeed Current to Input Source

2.2. Output Rating

Model
Continuous Output Power Maximum
Continuous Output Power Tolerance
Output Voltage Nominal (Single Phase) Line-Line
Operating Voltage Range Line-Line
Output Voltage Nominal (Single Phase) Line-Neutral
Operating Voltage Range Line-Neutral
Continuous Output Current Maximum
Continuous Output Current Tolerance
Voltage Measurement Tolerance
Operating Frequency Nominal
Operating Frequency Range
Operating Frequency Measurement Tolerance
Output Power Factor
Temperature Range Normal Operation
Output Over-Current Protection Maximum
Synchronization In-Rush Current Maximum
Utility Interconnection Trip Time
Time Measurement Tolerance

2.3. Other Specifications

Dimensions
Weight
Enclosure
NEMA 1 indicates that the enclosure is constructed for indoor use only. It provides protection to personnel
against incidental contact with the enclosed equipment.
Operator's Manual & Installation Instructions
Page 2
1.405.364.4212 /
www.bergey.com
PowerSync II
400 VAC
30 VAC
200 to 400 VAC
400 Hz
40 Amps
N/A
PSII12
PSII126208
12000 KW
10400 KW
±10%
240 VAC
208 VAC
212-264
184-228
120 VAC
106-132 VAC
50 Amps
± 10%
± 10 VAC
60 Hz
59.3 to 60.5 Hz
± 0.5 Hz
0.95 ± 0.05
-4°F to 113ºF / -20ºC to 45ºC
80 Amps
6.3 Amps
100 msec
85 msec
±
32.9"H x 24.3"W x 9" D
836 x 607 x 230 mm
153 lbs. / 64 Kg
NEMA Type 1
Rev: 1.1

Advertisement

Table of Contents
loading

Related Products for Bergey POWERSYNC II Series

This manual is also suitable for:

Powersync psii12Powersync psii126208

Table of Contents