p) Function "16:NEUTRAL", Calibrate Neutral Setting

This function allows the neutral setting for the steering wheel (see fig 1, pos 4)
and the control lever (see figure 1, pos 5) to be recalibrated.
Release the steering wheel and the control lever during the
calibration, do not move it!
Proceed as follows:
• From within the main menu (see fig. 5) press the "ENTER" button, then you
can use the "+" or "-" buttons to select the "16:NEUTRAL" function (fig 84).
• Then press the "ENTER" button again to reach the settings menu (fig 85).
• Switch between "YES" and "NO" with the "+" and "-" buttons.
If "YES" is selected (see fig 86), press the "ENTER" button to carry out the
calibration. The display shows "OK" see fig 87.
• You can exit the settings menu by pressing "EXIT".
Function11.2V
13:MIX
14:TH HOLD
15:F/S
16:NEUTRAL
NEUTRAL 11.2V
Set Neutral?
[NO] [YES]
READY
NEUTRAL 11.2V
Set Neutral?
[NO] [YES]
READY
NEUTRAL 11.2V
Set Neutral?
[NO] [YES]
OK
Figure 84
Figure 85
Figure 86
Figure 87