6.0 - Maintenance & Inspection (continued)
from service until the problem can be identified and corrected.
3. Overhead Anchor Points:
Ensure that the Tri-Ring Anchor is securely fastened and can rotate freely. The aluminum head piece and retaining
ring should be securely fastened and exhibit "near zero" free play. A non-rotating Tri-Ring Anchor may be indicative
of other damage, remove the product from service immediately if the Anchor Ring binds or does not rotate.
4. Structure:
The entire product structure should be checked for cracks, dents, bends or breaks. If dents, cracks, or any other
structural damage is witnessed, the unit must be removed from service and returned to the factory for repair.
• Pay special attention to areas of material transition (i.e. aluminum to composite): look for cracks or separa-
tion at such transitions. Be aware that powder coating can age and crack, this normal paint cracking can be
confused with structural cracking. If there is any uncertainty with regards to cracks, contact the Pelsue service
department for assistance and/or recommendations
5. Leveling Mounts (screws):
Ensure that the Leveling Screws are in working condition. Oil or grease the threaded rod if required. Also, visually
inspect to verify that the threading on the leveling screws has not been damaged in any way.