Installation & Maintenance Instructions
HYDRAMOTORr PUSH-TYPE LINEAR ACTUATORS
WARNING
To prevent the possibility of death, serious injury or
property damage, the Hydramotorr Actuator must be
installed and serviced only by a qualified service
technician avoiding the following hazards:
S Electrical hazard. Turn off all electrical power to
Hydramotorr Actuator. More than one circuit may
exist.
S Pressure hazard.
Depressurize valve and vent
hazardous or combustible fluid to a safe area before
inspection or removing the actuator or valve from
service.
S Explosion, fire or toxic gas hazards. Extinguish all
open flames and avoid any type of sparking or
ignition during leakage testing.
NOTICE: See separate valve installation and maintenance
instructions for information on: Operation, Positioning,
Mounting, Piping, Strainer or Filter Requirements, Flow
Controls, Preventive Maintenance, and Cause of Improper
Operation.
DESCRIPTION
AH2D Hydramotorsr are self-contained linear, push-type
actuators which extend when powered and retract by spring
force upon power interruption.
The AH actuator is typically used for control of gas-fired
heating equipment, commonly to open and close a valve or
both a valve and damper. AH2D actuators position V710
Series gas valve assemblies.
OPERATION
Application of electrical power simultaneously drives an
electric pump and closes a normally-open dump valve,
resulting in up to 250 pounds of force on the actuator stem. This
extends the actuator stem and attached valve poppet, to open
the valve and/or damper.
Upon reaching the fully extended position, a travel limit switch
interrupts power to the electric motor while maintaining power
to the dump valve, thus stabilizing hydraulic pressure to hold
shaft position. Position indicators on both sides of the actuator
show the actual position of the valve stem.
Upon power interruption, the dump valve opens releasing
hydraulic pressure, allowing the return spring to retract the
stem and close the valve fully. Closing time is one second or
less.
e
50-60 Hanover Road, Florham Park, New Jersey 07932
MCMXCIX
All Rights Reserved.
www.ascovalve.com
OPTIONAL FEATURES
S
Damper Shaft & Arm Shaft with all components to mount
damper arm on either side of actuator. Available with or
without return spring.
S
Auxiliary Switch One or two integral SPDT switches,
field adjustable to actuate at any position of stroke.
S
Overtravel Proof-of-Closure Switch A single factory set
non-field adjustable SPDT switch to be used in conjunction
with V710 Series Gas Valves with overtravel seal (V22 or
V25 suffix in catalog number).
AH2D
ACTUATOR
ASSEMBLY
NAMEPLATE/
ELECTRICAL
COVER
CONDUIT
KNOCKOUT
(2)
COVER
SCREW
VALVE
ASSEMBLY
Figure 1. AH2D Actuator (shown mounted
on V710 series gas valve)
ACTUATOR STEM
INTERNAL
SPRING
TRAVEL LIMIT
SWITCH
HOLE IS SHOWN 90_ OUT OF
TRUE POSITION
Figure 2. Cutaway schematic
(de-energized position)
Page 1 of 4
Printed in U.S.A.
AH2D
SERIES
HYDRAMOTORr
ACTUATOR
Form No.V8700R1
STEM POSITION
INDICATOR
DAMPER
ARM
(OPTIONAL)
DOWNSTREAM
PRESSURE TAP
UPSTREAM
PRESSURE TAP
PISTON
OIL FILL PLUG
HYDRAULIC
FLUID LEVEL
RESERVOIR
MOUNTING
SET SCREW (2)