Mount Cover Plate to a Vertical 2 in. X 4 in. Electrical Box (See Fig. 3)
1. Position the bracket on the electrical box. Insert two #6-32 X 5/8 flat head screws. Check leveling, if
desired, and tighten the flat head screws.
2. Pull the wires through the wire hole on the cover plate and wall plate. Position the cover plate and wall
plate on the bracket with the arrows pointing up.
3. Insert two #6-32 X 1/4 pan head screws and tighten.
ELECTRICAL BOX
Fig. 3. Mount bracket, cover plate, wall plate and thermostat to a vertical 2 in. X 4 in. electrical box.
WIRE
BRACKET
#6-32 X 5/8 FLAT
HEAD SCREWS (2)
THP2400A1019 COVER PLATE ASSEMBLY
COVER PLATE
WIRE HOLE
MOUNTING HOLES (2)
3
WALL PLATE
WIRE HOLE
MOUNTING HOLES (2)
#6-32 X 1/4 PAN
HEAD SCREWS (2)
THERMOSTAT
M34260
69-2762EFS—02