For the Installer

5. INSTALLATION

Before installing this unit, please take the time to carefully read page 2 of this guide to ensure it is installed safely
and properly.
5.1 L
U
OCATING THE
NIT
Choose an appropriate location for the unit.
Within an area of the house where the ambient temperature is between 10°C (50°F) and
50°C (122°F) (basement, furnace room, closet, etc.)
Away from living areas (dining room, living room, bedroom), if possible
So as to provide easy access to the interior of the unit, for maintenance
Close to an exterior wall, so as to limit the length of the insulated flexible duct to and from
the unit
Away from hot chimneys and other fire hazards
Allow for a standard 3-prong grounding outlet within 3 feet of the unit
Close to a drain. If no drain is close by, use a pail to collect run-off
Slightly bend all 4 hooks located on both sides of the unit in order to hang it to ceiling joists
with the 4 chains and springs provided. See illustration aside.
Make sure the unit is level.
5.2 I
NSTALLING THE DUCTWORK AND REGISTERS
• Never install a stale air exhaust register in a closed room where a combustion device operates, such as a gas
furnace, a gas water heater or a fireplace.
• When performing duct connections, always use approved tools and materials. Respect all corresponding laws
and safety regulations. Please refer to your local building code.
Keep it simple. Plan for a minimum of bends and joints
Keep the length of insulated ducts to a minimum
If the house has two floors or more, be sure to plan for at least one exhaust register at the highest lived-in level
5.2.1 F
ULLY DUCTED SYSTEM
Stale air exhaust ductwork
Install the stale air exhaust registers where the contaminants are produced:
kitchen, living room, etc. Position the registers as far from the stairway as
possible and in such a way that the air circulates in all the lived-in spaces in
the house
If a register is installed in the kitchen, it must be located at least 4 feet (1.2 m)
away from the range
Install the registers on an interior wall, 6 to 12 inches (152 to 305 mm) away
from the ceiling OR in the ceiling
Fresh air distribution ductwork
Install the fresh air distribution registers in bedrooms, dining rooms, living
room and basement
Keep in mind that the fresh air registers must be located as far as possible
from the stale air registers
Install the registers either in the ceiling or high on the walls, with the air flow
directed towards the ceiling
If a register must be installed in the floor, direct the airflow up the wall