FORTEZA -50 Description Manual & Service Instruction

Local microwave protective detector

Advertisement

Quick Links

JSC FORTEZA
Please visit our internet sites:
Local Microwave Protective Detector
"Forteza-50"
"Forteza-100"
"Forteza-200"
Description Manual & Service Instruction
4372-43071246-065 ТО
2012
www.forteza.com www.forteza.eu
FORTEZA-50, 100, 200
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Forteza-50 and is the answer not in the manual?

Questions and answers

Summary of Contents for FORTEZA Forteza-50

  • Page 1 JSC FORTEZA FORTEZA-50, 100, 200 Local Microwave Protective Detector “Forteza-50” “Forteza-100” “Forteza-200” Description Manual & Service Instruction 4372-43071246-065 ТО 2012 Please visit our internet sites: www.forteza.com www.forteza.eu Page 1...
  • Page 2: Table Of Contents

    JSC FORTEZA FORTEZA-50, 100, 200 CONTENTS 1. Introduction ........................3 2. Purpose ..........................3 3. Specifications ........................3 4. Detector Components ...................... 5 5. Detector Structure & Operation ..................5 5.1. Detector Principle of Operation ................... 5 5.2. Adjustment, Control and Indication Parts ..............5 5.3.
  • Page 3: Introduction

    The present description manual and service instruction contains information about the operation of the local microwave protective detectors “Forteza-200”, “Forteza-100”, “Forteza-50” (below the detector). In this document there is information required for the correct operation (use, transportation, storage and maintenance) of the detector.
  • Page 4 JSC FORTEZA FORTEZA-50, 100, 200 Dimensions, Length of a sector L, m maximum, 1, 5 2, 1 3.3. The distance recommended from the axis of the detection zone up to guarding, building walls and other nonmoving objects should be as follows: 80…200m...
  • Page 5: Detector Components

    JSC FORTEZA FORTEZA-50, 100, 200 influence of the radiated emission of ultra short waves of the range 150-175 MHz up to 40 Vat on the distance 6 m maximum. 3.11. The detector is immune to EMI: voltage impulses in supply circuits, breaks of main supply, electrostatic discharges, and electromagnetic fields.
  • Page 6: Detector Operation

    JSC FORTEZA FORTEZA-50, 100, 200 5.2.2. The input signal is controlled with the tester on the socket that is marked "TEST" (test jack).The more TEST the more Rx input signal and vise versa. The detector keeps its operation with the range of the voltage values too: TEST 0,1-4,8 V.
  • Page 7: Tx Construction

    JSC FORTEZA FORTEZA-50, 100, 200 6.2. Tx Construction 6.2.1. Tx construction and its bracket are the same as the Rx construction (see fig.6.1). The difference is in internal elements: cover 6, clamps, controls, adjustment and indication elements are absent; three wire cables are used instead of cable 8.
  • Page 8 JSC FORTEZA FORTEZA-50, 100, 200 1 - indicator "PROTECTION" 2 – threes holding “MIN-MAX” 3 - socket "TEST" 4 – “AGC” button 5 - tamper circuit 6 - marking of cable cords Fig.6.2. Note. Dear user! The manufacturer of the detector constantly upgrades their quality and reliability.
  • Page 9 JSC FORTEZA FORTEZA-50, 100, 200 Fig.6.3 Table 6.1. Max detection Max detection Max detection Sensor zone length (L), zone width (B), zone height (H), Notes FORTEZA-200 FORTEZA-100 FORTEZA-50 Notes. 1. If the upper part of the fence is protected with physical protection devices, it is necessary to use the bracket of 500 mm.
  • Page 10 JSC FORTEZA FORTEZA-50, 100, 200 1 - fence; 4 - washer 6 -1шт.; 5 - nut М6 2 - bracket -1шт.; -1шт.; 3 - figured washer -1шт.; 6 - ring -1шт. Fig. 6.4 Please visit our internet sites: www.forteza.com www.forteza.eu...
  • Page 11 JSC FORTEZA FORTEZA-50, 100, 200 Fig. 6.5 –1 item; 7- bolt М6х35 – 1item; 1- fence – 1item; – 1item; 2- bracket 8- ring – 2items; 9- nut М6 – 3- figured washer 2items; – 1item; – 4items; 4- bracket fastener 10- washer 6 –...
  • Page 12: Safety Measures

    JSC FORTEZA FORTEZA-50, 100, 200 7. SAFETY MEASURES 7.1. The current safety standards for the operation with electrical facilities with the voltage up to1000 V should be observed during mounting, preventive maintenance and repair of the sensor. 7.2. Cables should be laid, terminated and connected to the sockets only when the supply voltage is OFF.
  • Page 13 JSC FORTEZA FORTEZA-50, 100, 200 Fig.8.1 Fig.8.2 8.2.3. The supports can be mounted with concreting. The other variants of the sensor mounting (for example on a fence, on a building wall) can be chosen according to the results of the operation test. As a fence deforms the detection zone configuration, the sensor operation depends on the exact place of its mounting.
  • Page 14 JSC FORTEZA FORTEZA-50, 100, 200 Stretch the cable 8 through the corrugated tube 7. The installation of the corrugated tube is obligatory. 8.2.6. Install junction boxes and power supply units (if according to the project PSU are installed within the perimeter).
  • Page 15: Sensor Connection

    JSC FORTEZA FORTEZA-50, 100, 200 1 - support; 2 - plastic plug; 3 - hole for the cable input inside the support; 4 - hole for the main cable and sensor cable input; 5 - hole for the main cable input;...
  • Page 16 JSC FORTEZA FORTEZA-50, 100, 200 Table 8.1 Colour Purpose Colour Purpose «+» supply «+» supply voltage white white voltage «-» supply «-» supply voltage brown brown voltage remote control yellow actuating relay contacts green «RC»+5…30 V «NC» pink green blocking button contacts «TAMPER»...
  • Page 17 JSC FORTEZA FORTEZA-50, 100, 200 Terminator – terminator of the control-receiving device Fig. 8.4 Please visit our internet sites: www.forteza.com www.forteza.eu Page 17...
  • Page 18 JSC FORTEZA FORTEZA-50, 100, 200 Terminator – terminator of the control-receiving device Fig. 8.5 Please visit our internet sites: www.forteza.com www.forteza.eu Page 18...
  • Page 19 JSC FORTEZA FORTEZA-50, 100, 200 Fig. 8.6. Please visit our internet sites: www.forteza.com www.forteza.eu Page 19...
  • Page 20: Preparation Of The Detector For The Operation & Adjustment

    JSC FORTEZA FORTEZA-50, 100, 200 9. PREPARATION OF THE SENSOR FOR THE OPERATION AND ADJUSTMENT 9.1. Sensor preparation for its operation 9.1.1. Check the connection of supply circuits and output circuits of the sensor. Switch ON the sensor power supply. Interrupted or constant glowing of the indicator «PROTECTION»...
  • Page 21: Check Of Technical State

    JSC FORTEZA FORTEZA-50, 100, 200 Align the thresholds very attentively as «underrating» of the thresholds might provoke a lot of false alarms; «overrating» of the thresholds might provoke failures in the sensor operation. Close the Rx cover when the alignment is finished.
  • Page 22: Troubleshooting Guide

    JSC FORTEZA FORTEZA-50, 100, 200 11. TROUBLESHOOTING GUIDE List of possible troubles is given in Table 11.1. Table 11.1 Trouble Possible Cause Repair 1.The receiving - control Check the cable integrity device constantly 1. Communication line is and the accuracy of its generates an alarm.
  • Page 23: Storage

    JSC FORTEZA FORTEZA-50, 100, 200 12. STORAGE 12.1. The sensors should be warehoused in the package at an ambient temperature from +5С up to +30 С and relative humidity 85% maximum. During storage the influence of hostile environment should be prevented.
  • Page 24: Certificate

    JSC FORTEZA FORTEZA-50, 100, 200 Microwave Linear Intrusion Sensor «FORTEZA-200», «FORTEZA-100», «FORTEZA-50», Certificate Document Part Number 4372-43071246-041 The purpose of the sensor and its specifications are given in the respective items of the user manual 4372-43071246-041. CERTIFICATE №:1100501 of 16.7.2010 1.