Ravel RE 150D Installation, Commissioning & Operating  Manual

Ravel RE 150D Installation, Commissioning & Operating Manual

Fire alarm control panel

Advertisement

RE – 150D
Fire Alarm Control Panel
Installation, Commissioning & Operating
Manual
RAVEL ELECTRONICS PVT LTD.,
150-A, Electronics Industrial Estate,
Perungudi, Chennai - 600 096.
Ph.: 91-44-24961004, 24960825.
Fax: 91- 44 - 42049599.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RE 150D and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ravel RE 150D

  • Page 1 RE – 150D Fire Alarm Control Panel Installation, Commissioning & Operating Manual RAVEL ELECTRONICS PVT LTD., 150-A, Electronics Industrial Estate, Perungudi, Chennai - 600 096. Ph.: 91-44-24961004, 24960825. Fax: 91- 44 - 42049599.
  • Page 2 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 3 Smoke detectors are designed to alarm at various levels of smoke density. If such density levels are not created by a developing fire at the location of detectors, the detectors will not go into alarm. 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 4 Any warning device may fail to alert people with a disability or those who have recently consumed drugs, alcohol or medication. 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 5 Maintenance should be scheduled monthly or as required by National and/or local fire codes and should be performed by authorized professional fire alarm installers only. Adequate written records of all inspections should be kept. 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 6 NOTES: 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 7: Table Of Contents

    5.1: Walk test mode… ……………………......24 5.2: Installation/Replacement of PCB........…25 5.3: Test……..............….25 5.4: Lamp Test…..............….26 CHAPTER 6: Power Calculation….….………………………26 CHAPTER 7: Trouble Shooting……….……………………..27 CHAPTER 8: Wire Requirement……….……..………….….28 CHAPTER 9: Abbreviation……..….………………….….…29 General Arrangement diagram……………………………...30 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 8: Chapter 1: Introduction

    Chapter 1: Introduction This manual is intended as a complete guide to the RE 150D model Conventional Fire Control Panel. User operating Instructions are provided in the first part of this manual. This is followed with sections describing installation and commissioning procedures and full technical details are provided.
  • Page 9: Fire Alarm Procedure

    As a minimum, the user shall record any incident and inform the service organization, who may be required to retest the system. The user's responsibilities are described fully in IS 2189: 1999. 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 10: Routine Test

    Note: The control panel case should be cleaned periodically by wiping with a soft, damp cloth. Do not use any solvents. 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 11: Chapter 2: Product Description

    Twin RED LED indication for fire. Zone Isolation facility with loop voltage cut off. Earth Fault with Audio and Visual Indications. Supervised Sounder 24v DC output for External notification devices (Sounder, Bell, etc.). 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 12: Specifications

    Three Form – C Relays Relay Contact Rating: 2Amps @ 30 VDC, 2Amps @ 30VAC (Fire – 3 No’s). 24 VDC Power – For remote devices Operating Voltage: 24VDC, 500mA Max. 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 13: Controls And Indicators

    Battery Low – Yellow Common Hooter Fault – Yellow AUX. Isolate – Yellow Walk Test – Yellow Silence – Yellow Zone Fire – Red Zone Fault – Yellow Zone Isolate – Yellow 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 14: 2: Controls

    3 seconds for Detectors and MCPs, Then voltages are put on to the loop. Note: The zone loop voltage will cut off only in fire condition during reset. 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 15: Mechanical Construction

    The panel also has a built in battery provision to accommodate 2 Nos. of 12v, 7Ah batteries (Up to 12 Zone). The front side of the panel consists of the following, Tactile switches. LED indications 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 16: Chapter 3: Installation

    Therefore, it is recommended that this system and all peripherals be installed in an environment with a nominal room temperature of 0- 50° C/32-120° F. 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 17 Follow the instructions in the installation, operating, and programming manuals. These instructions must be followed to avoid damage to the control panel and associated equipment. FACP operation and reliability depend upon proper installation by authorized personnel. 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 18: Mounting Details

    When the installation of all the cables has been completed, clean the interior of the enclosure ensuring all masonry debris and drilling swords are removed. 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 19: Input Circuits

    2-wire, 24 volt smoke detectors. It is allowable to mix an assortment of device types (i.e. smoke detectors, heat detectors, pull stations, etc.) on any zone. Zone Circuit – Class B 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 20: Output Circuits

    30 VDC and 2.0 amps @ 30 VAC. Relay connections may be power-limited or nonpower-limited, provided that a minimum of 0.25" is maintained between conductors of power-limited and nonpower-limited circuits. 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 21: Chapter 4: Operating Instructions

    LAMP TEST Key: This key is used to check the all LED’s in panel is in good condition with continuous buzzer tone. SELECT Key: This key is used to select the particular zone for the self test and isolation purpose. 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 22: Status Led

    BATTERY LOW: Whenever the backup battery voltage goes below the 21v, the low battery LED will be illuminated and it also indicated with toggle Buzzer tone. CHARGER ON: This LED indicates the condition of charging circuit. 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 23: Operation

    When the control panel detects Fire via the Detector / MCP, the corresponding ZONE FIRE red LED will be illuminated. At the same time hooter, potential free contact (Fire Relay) and local buzzer (continuous tone) will be activated. 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 24: 4: Zone Fire Restoral

    The OFF status indicates the zone is in monitoring condition. For Zone Isolation the follow the steps given below. a. Press the ‘select’ key zone1 selects first with indication of isolate LED blinking. 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 25: Chapter 5: Servicing

    3 seconds the panel will get automatically silenced. After 6 seconds of silence, the panel will go to reset. This reset is done for only that particular zone. 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 26: Installation/Replacement Of Pcb

    To test a particular zone, follow the procedure as below 1. Press the ‘select’ key zone1 selects first with indication of isolate LED blinking. 2. Press ‘select’ key consequently until select the zone which is to be test. 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 27: Lamp Test

    X = S (0.0772A) x 48 Hrs. = 3.7056 Y = F (0.94A) x 1 Hrs. = 0.94 AH = X+ Y = (3.7056+ 0.94) X 1.2 = 5.57472Ah 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 28: Chapter 7: Trouble Shooting

    IN4007 each hooter’s +ve loop is connected to 1N 4007 diode’s Hooter cathode and the (NAC) hooter –ve loop connected to the anode of 1N 4007. 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 29: Chapter 8: Wire Requirement

    ) - 18 AWG 24 VDC limitation set by annunciators allowed from (0.75 mm resettable, 1.2 volt and other supply source nonresettable maximum accessories to end of any line drop branch 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 30: Chapter 9: Abbreviation

    Institute of Electrical Engineering End Of Line Printed Circuit Board Central Processing Unit Manual Call Point S.Nos Serial Numbers milli Ampere killo grams CO,NO,NC- Common, Normally Open, Normally Closed 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 31: General Arrangement Diagram

    General Arrangement Diagram: 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 32 This is to certify that the following items are tested and checked. Microprocessor Based Conventional Fire Alarm Control Panel. Model No.: RE – 150D Serial No.: No. of zones: For RAVEL ELECTRONICS PVT.LTD, Q.C. – Engineer Tested By 6/28/2011 DOC.NO.: 150D - 1 P/N RE 150D Rev. No. 1...
  • Page 33 RE – 150D Serial No.: Ravel Electronics warrants each product to be free from defects in material and workmanship. This obligation is limited to servicing or part returned to the company for that purpose and making good any parts thereof which shall be within warranty period, returned to the company under a written intimation and which to the company’s satisfaction to be found defective.