Alpha AS600M Series Manual page 19

Table of Contents

Advertisement

10V Analog Powrer
0 ~ 10V/4 ~20mA Input
-10V ~+ 10V Input
Analog Ground
24V Control Power
Forward/Run
Reverse
Control Enable
Orietation
accurate stop
rigid tapping/pulse position
Multi function input
Multi function input
Control power common
command pulse input A/P+
command pulse input A/P-
command pulse input B/D+
command pulse input B/D-
to CNC
encoder output A+
encoder output A-
encoder output B+
encoder output B-
encoder output Z+
encoder output Z-
10V
SW1
AI1
I
AI2
V
GND
AI1
PE
24V
X1
X2
X3
X4
X5
X6
X7
COM
A/P+
A/P-
B/D+
B/D-
OA+
OA-
OB+
OB-
OZ+
OZ-
DB15
Matching resistance
2-15 wiring diagram
Chapter 2 Installation and Wiring
SW1
0 ~ 10V/4 ~ 20mA output
GND
I
V
AO1
AI1
reach the speed
Y1
driver ready
Y2
Y3
accurate stop in place
output common
CME
TA
fault output
TB
TC
DB15
5V
0V
A+
A-
B+
B-
Z+
Z-
SW6
485+
ON ON
ON
485-
OFF
RS485
GND
motor encoder inp
RS485
19